## 1. Rated capacity.

**Citation:** 49 CFR 178.354-2  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 2003-10-01 / Not stated

(b) \[Reserved\] \[Amdt. 178-1, 33 FR 14935, Oct. 4, 1968. Redesignated by Amdt. 178-97, 55 FR 52716, Dec. 21, 1990, as a

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-2003-title49-vol2/CFR-2003-title49-vol2-sec178-354-2>
- Source ID: `govinfo-cfr`
- SHA-256: `83d1b87f58880996d648586078f41e7b1a0ba846940c221504a2d039fd61774e`
- Retrieved: 2026-08-13T06:37:29.399Z
- Document slug: `49-cfr-178-354-2`
- Related records: 0

## 2. General requirements.

**Citation:** 49 CFR 178.354-1  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 2003-10-01 / Not stated

(b) \[Reserved\] \[Amdt. 178-1, 33 FR 14935, Oct. 4, 1968. Redesignated by Amdt. 178-97, 55 FR 52716, Dec. 21, 1990\]

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-2003-title49-vol2/CFR-2003-title49-vol2-sec178-354-1>
- Source ID: `govinfo-cfr`
- SHA-256: `de2ad886038d5262a316f2a0f715b0adad0dd3bfe516c401511e1bdc04505232`
- Retrieved: 2026-08-13T06:37:29.399Z
- Document slug: `49-cfr-178-354-1`
- Related records: 0

## 3. Markings.

**Citation:** 49 CFR 178.354-5  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 2003-10-01 / Not stated

(a) Marking must be as prescribed in § 178.3. (b) Marking on the outside of each package must be as follows: “DOT-6M Type B,” “Radioactive Materials,” or “Fissile Radioactive Materials,” as appropriate; and the gauge of metal of the outer drum in the thinnest part, rated capacity of the outer drum 

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-2003-title49-vol2/CFR-2003-title49-vol2-sec178-354-5>
- Source ID: `govinfo-cfr`
- SHA-256: `b07d0eb5cc57a57e164f3b1aed0a09e4b6ac8a5586b4031bb3b6dbb104941a56`
- Retrieved: 2026-08-13T06:37:29.399Z
- Document slug: `49-cfr-178-354-5`
- Related records: 0

## 4. Closure.

**Citation:** 49 CFR 178.352-5  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 2003-10-01 / Not stated

(a) The outer drum closure must be at least a 12-gauge bolted ring with drop forged lugs, one of which is threaded, and having at least a 1.6 centimeter (5/8-inch) diameter steel bolt and a lock nut, or equivalent device. (b) The closure device must have a means for the attachment of a tamper-proof

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-2003-title49-vol2/CFR-2003-title49-vol2-sec178-352-5>
- Source ID: `govinfo-cfr`
- SHA-256: `20fcaf559b7dda59b16bbd624a1d3f497c3b212382d1dbd82f1ed697c11b13bd`
- Retrieved: 2026-08-13T06:37:29.399Z
- Document slug: `49-cfr-178-352-5`
- Related records: 0

## 5. Closure.

**Citation:** 49 CFR 178.354-4  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 2003-10-01 / Not stated

(a) The outer drum closure must be at least 16-gauge bolt-type locking ring having at least a 5/16-inch steel bolt for drum sizes not over 15 gallons, or a 12-gauge bolted ring with drop-forged lugs, one of which is threaded, and a 5/8-inch steel bolt for drum sizes over 15 gallons. Each bolt must b

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-2003-title49-vol2/CFR-2003-title49-vol2-sec178-354-4>
- Source ID: `govinfo-cfr`
- SHA-256: `8c85e0007f9aae89792fb39ffceaced6ccc71a3247fb923d1cc8141ecbf4d539`
- Retrieved: 2026-08-13T06:37:29.399Z
- Document slug: `49-cfr-178-354-4`
- Related records: 0

## 6. General construction requirements.

**Citation:** 49 CFR 178.354-3  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 2003-10-01 / Not stated

(a) The outer shell must be of straight-sided steel, with welded body seams, and may be either a single sheet of steel, or may be fabricated by welding together two appropriate lengths of drums with each length to contain 3 swedged or rolled rolling hoops as prescribed for either of these specificat