## 1. Combustion engines and turbines.

**Citation:** 49 CFR 193.2147  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

\[45 FR 9203, Feb. 11, 1980, as amended at 58 FR 14522, Mar. 18, 1993\]

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2147>
- Source ID: `govinfo-cfr`
- SHA-256: `27cfa5a2e54612ca6ec199ff50e08fab125089613f68f45a29fcd68f3e40c5b5`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2147`
- Related records: 1

## 2. Concrete storage tanks.

**Citation:** 49 CFR 193.2213  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

\[45 FR 9203, Feb. 11, 1980, as amended at 58 FR 14522, Mar. 18, 1993\]

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2213>
- Source ID: `govinfo-cfr`
- SHA-256: `25acc5c125067944e3cc1f9822f9a581bc7d164d8198ee61d9d86428421a4a6f`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2213`
- Related records: 1

## 3. Storage of flammable fluids.

**Citation:** 49 CFR 193.2813  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

\[45 FR 9203, Feb. 11, 1980, as amended at 58 FR 14522, Mar. 18, 1993\]

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2813>
- Source ID: `govinfo-cfr`
- SHA-256: `d356cdbad3d965a857ae84112130cfc0f76d69839784ec248caa2a1bb4d2d8a5`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2813`
- Related records: 1

## 4. Hotwork.

**Citation:** 49 CFR 193.2811  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

\[45 FR 9203, Feb. 11, 1980, as amended at 58 FR 14522, Mar. 18, 1993\]

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2811>
- Source ID: `govinfo-cfr`
- SHA-256: `ef82a9900c38c106861cd89ee7e1664e97fb3479a8765fcde04f48f7b0bd95fc`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2811`
- Related records: 1

## 5. Construction acceptance.

**Citation:** 49 CFR 193.2303  
**Type / status:** regulation / current  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 2026-08-18 / Not stated

\[45 FR 9203, Feb. 11, 1980, as amended by Amdt. 193-17, 65 FR 10960, Mar. 1, 2000; Amdt. 193-18, 69 FR 11337, M

### Provenance

- Official: Yes
- Source: <https://www.ecfr.gov/on/2026-08-18/title-49/section-193.2303>
- Source ID: `ecfr`
- SHA-256: `9e641b6c738fe612a82c7289ff744a541c24dedb888047c112658045dd3d334d`
- Retrieved: 2026-08-20T05:54:35.243Z
- Document slug: `49-cfr-193-2303`
- Related records: 21

## 6. Dike dimensions.

**Citation:** 49 CFR 193.2165  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

In addition to dike dimensions needed to comply with other requirements of this subpart, to minimize the possibility that a trajectory of accidentally discharged liquid would pass over the top of a dike, the horizontal distance from the inner wall of the component or vessel served to the closest ins

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2165>
- Source ID: `govinfo-cfr`
- SHA-256: `3f09d92873bd4b7e26bf0396e654fa89bb90b56b396a1711f2837688a56025b2`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2165`
- Related records: 2

## 7. General.

**Citation:** 49 CFR 193.2427  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

(a) Control systems must comply with the requirements of this subpart and other applicable requirements of this part. (b) Each control system must be capable of performing its design function under normal operating conditions. (c) Control systems must be designed and installed in a manner to permi

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2427>
- Source ID: `govinfo-cfr`
- SHA-256: `f2f30b4ca41a18dbda0c180165346c7f9d6062a0b5ff9d98577d7bb32f1e4eeb`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2427`
- Related records: 2

## 8. Inspection.

**Citation:** 49 CFR 193.2307  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

(a) All construction, installation, and testing activities must be inspected as frequently as necessary in accordance with a written plan to assure that— (1) Activities are in compliance with all applicable requirements of this subpart; and (2) Components comply with the applicable material, desig

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2307>
- Source ID: `govinfo-cfr`
- SHA-256: `641c84fa668cdeeca68ee8c14bfcea4412d079d3528a22f919c234a000fab040`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2307`
- Related records: 4

## 9. Fire detection.

**Citation:** 49 CFR 193.2821  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

(a) Fire detectors that continuously monitor for the presence of either flame, heat, or products of combustion must be provided in all areas determined under § 193.2805(a)(2) in which a hazard to persons or property could exist and in all other areas that are used for the storage of flammable or com

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2821>
- Source ID: `govinfo-cfr`
- SHA-256: `ae6826e2b55f5c02e53865f1a58378514f121c5a114c7443d48b5d609354bff0`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2821`
- Related records: 3

## 10. Impoundment required.

**Citation:** 49 CFR 193.2149  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

(a) An impounding system must be provided for storage tanks to contain a potential spill of LNG or other hazardous liquid. (b) Grading or drainage or an impounding system must be provided to ensure that accidental spills or leaks from the following components and areas do not endanger components or

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2149>
- Source ID: `govinfo-cfr`
- SHA-256: `47f4f95123e86f0411a3ecc66c9d74fb64f90ec26b770690bc1dbcb49260fa28`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2149`
- Related records: 3

## 11. Sensing devices.

**Citation:** 49 CFR 193.2433  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

(a) Each operator shall determine the appropriate location for and install sensing devices as necessary to— (1) Monitor the operation of components to detect a malfunction which could cause a hazardous condition if permitted to continue; and (2) Detect the presence of fire or combustible gas in ar

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2433>
- Source ID: `govinfo-cfr`
- SHA-256: `925836717444a582ad7f3996c273a6293075d5680c037c95d47ea75665403f8f`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2433`
- Related records: 2

## 12. Insulation.

**Citation:** 49 CFR 193.2109  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

During normal operations, insulation materials must: (a) Maintain insulating values; (b) Withstand thermal and mechanical design loads; and (c) Be covered with a material that is noncombustible in the installed state, is not subject to detrimental ultraviolet decay, and that can withstand the for

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2109>
- Source ID: `govinfo-cfr`
- SHA-256: `c35f4db9a015803f858c77095998b56ecc157e811c975941e8762189431caf75`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2109`
- Related records: 0

## 13. Separation of facilities.

**Citation:** 49 CFR 193.2073  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

Each LNG facility site must be large enough to provide for minimum separations between facilities and between facilities and the site boundary to: (a) Permit movement of personnel, maintenance equipment, and emergency equipment around the facility; and (b) Comply with distances specified in sectio

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2073>
- Source ID: `govinfo-cfr`
- SHA-256: `7edf95ff4483def95b11d18e6d9c0a50060f8a41c911730d639e2910fd6bf175`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2073`
- Related records: 2

## 14. Piping.

**Citation:** 49 CFR 193.2113  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

(a) Piping made of cast iron, malleable iron, or ductile iron may not be used to carry any cryogenic or hazardous fluids. (b) Piping materials intended for normal use at temperatures below −28.9° C (−20° F) or for use under § 193.2107(c)(1) must be qualified by testing in accordance with ASME/ANSI 

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2113>
- Source ID: `govinfo-cfr`
- SHA-256: `165b1605f52732bd5ab1d9657e756c0feef771d09bcf83fcbb27954b4d44420a`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2113`
- Related records: 0

## 15. Valves.

**Citation:** 49 CFR 193.2123  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

(a) Each valve, including control valves and relief valves, must be designed, manufactured, and tested to comply with ASME/ANSI B31.3 or ASME/ANSI B31.5 or ASME/ANSI B31.8 or API Standard 6D, if design conditions fall within their scope. (b) Extended bonnet valves must be used for service temperatu

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2123>
- Source ID: `govinfo-cfr`
- SHA-256: `e81b75d12f5dbb37d21f14f0600c738876203ff67d7ac8d12db470aeb62554a2`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2123`
- Related records: 1

## 16. Storage tank tests.

**Citation:** 49 CFR 193.2327  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

(a) In addition to other applicable requirements of this subpart, storage tanks for cryogenic fluids with internal design pressures of not more than 15 psi (103 kPa) gage must be tested in accordance with sections Q8, Q9, and Q10 of API 620, appendix Q, as applicable. (b) Metal storage tanks for cr

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2327>
- Source ID: `govinfo-cfr`
- SHA-256: `e3685292516f0044095c899032d70b5e7b589c63c4e993489d568febf79a0179`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2327`
- Related records: 3

## 17. Classes of impounding systems.

**Citation:** 49 CFR 193.2153  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

(a) For the purpose of this part, impounding systems are classified as follows: Class 1. A system which surrounds the component served with the inner surface of the dike constructed against or within 24 inches (610 millimeters) of the component served. Class 2. A system which surrounds the componen

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2153>
- Source ID: `govinfo-cfr`
- SHA-256: `d70c1ffca6dea7233a6e805989a9c085be9d541f5a735e4758157abbb5f51d14`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2153`
- Related records: 4

## 18. Shutoff valves.

**Citation:** 49 CFR 193.2233  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

(a) Shutoff valves on transfer systems must be located— (1) On each liquid supply line, or common line to multiple supply lines, to a storage tank, or to a cargo transfer system; (2) On each vapor or liquid return line from multiple return lines, used in a cargo transfer system; (3) At the connec

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2233>
- Source ID: `govinfo-cfr`
- SHA-256: `aaa0ab90645a1edd77d7c4cb785b8e7560c097df3d74a7f782b8e3cefce32c09`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2233`
- Related records: 5

## 19. Strength tests.

**Citation:** 49 CFR 193.2319  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

(a) A strength test must be performed on each piping system and container to determine whether the component is capable of performing its design function, taking into account— (1) The maximum allowable working pressure; (2) The maximum weight of product which the component may contain or support; 

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2319>
- Source ID: `govinfo-cfr`
- SHA-256: `872124ba3c3b4f73ce7462b76429f315b466a93f6cf678f9525906e83fac9a31`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2319`
- Related records: 2

## 20. Fire prevention plan.

**Citation:** 49 CFR 193.2805  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

(a) Each operator shall determine— (1) Those potential sources of ignition located inside and adjacent to the LNG plant which could cause fires that affect the safety of the plant; and (2) Those areas, as described in section 500-5 of ANSI/NFPA 70, where the potential exists for the presence of fl

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2805>
- Source ID: `govinfo-cfr`
- SHA-256: `37b8f7ed0b8f191613599e34d3508533022396ca45f80dc54f58c30372ee7927`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2805`
- Related records: 2

## 21. Vents.

**Citation:** 49 CFR 193.2431  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

(a) Hazardous fluids may not be relieved into the atmosphere of a building or other confined space. (b) Boiloff vents for hazardous fluids may not draw in air during operation. (c) Venting of natural gas/vapor under operational control which could produce a hazardous gas atmosphere must be directe

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2431>
- Source ID: `govinfo-cfr`
- SHA-256: `69f01fde13bdc343feacd4c9d6cefaf755563df102e6296c3e8ee5486c818621`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2431`
- Related records: 2

## 22. Metal storage tanks.

**Citation:** 49 CFR 193.2211  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

(a) Metal storage tanks with internal design pressures of not more than 15 psi (103 kPa) gage must be designed and constructed in accordance with API Standard 620 and, where applicable, appendix Q of that standard. (b) Metal storage tanks with internal design pressures above 15 psi (103 kPa) gage m

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2211>
- Source ID: `govinfo-cfr`
- SHA-256: `8d976ffd7f139468cdeea6033d1b1b7b1c489b52107b1991ac8541063015ac4d`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2211`
- Related records: 4

## 23. Pipe welding.

**Citation:** 49 CFR 193.2313  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

(a) Each operator shall provide the following for welding on pressurized piping for LNG and other hazardous fluids: (1) Welding procedures and welders qualified in accordance with section IX of the ASME Boiler and Pressure Vessel Code or API 1104, as applicable; (2) When welding materials that are

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2313>
- Source ID: `govinfo-cfr`
- SHA-256: `b4c7a5c804c2290c3a9398cd4e6d4d23f000e1a7a20ccbc53d9d7f4428076d0e`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2313`
- Related records: 2

## 24. Piping.

**Citation:** 49 CFR 193.2127  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

(a) Piping must be designed, manufactured, and tested to comply with ASME/ANSI B 31.3. (b) All cryogenic and hazardous fluid piping must have connections to facilitate blowdown and purge as required by this part. (c) Each cryogenic or hazardous fluid piping system that is aboveground must be ident

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2127>
- Source ID: `govinfo-cfr`
- SHA-256: `29e1d6e84bb92a44d9ae39c30444beed8d92e953a0f1442ee94fa550fc36121e`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2127`
- Related records: 1

## 25. Penetrations.

**Citation:** 49 CFR 193.2195  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

(a) All penetrations in an LNG storage tank must be designed in accordance with API 620, including appendix Q. (b) The loadings on all penetrations must be determined by an analysis of all contributing forces, including those from tank thermal movements, connecting piping thermal movements, hydraul

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2195>
- Source ID: `govinfo-cfr`
- SHA-256: `d087c2fe178a8b9d55b7e8049df0a48a9dabad834989e3e7456ff54193816fd5`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2195`
- Related records: 2

## 26. Stratification.

**Citation:** 49 CFR 193.2191  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

LNG storage tanks with a capacity of 5,000 barrels (795 cubic meters) or more must be equipped with means to mitigate a potential for rollover and overpressure such as: (a) Selective filling at the top and bottom of the tank; (b) Circulating liquid from the bottom to the top of the same tank; or 

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2191>
- Source ID: `govinfo-cfr`
- SHA-256: `9564f4b9da5c43b5a723ac655c42d437d42c9773fd52f67b074855aaadbcd45b`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2191`
- Related records: 4

## 27. Buildings: ventilation.

**Citation:** 49 CFR 193.2133  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

(a) Each building in which potentially hazardous quantities of flammable fluids are handled must be ventilated to minimize the possibility, during normal operation, of hazardous accumulation of a flammable gas and air mixture, hazardous products of combustion, and other hazardous vapors in enclosed 

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2133>
- Source ID: `govinfo-cfr`
- SHA-256: `8cbe556ac688cbf1d071d0a5bef0b91a374624ece0713c3ccffd03ffd7715d32`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2133`
- Related records: 2

## 28. Cargo transfer systems.

**Citation:** 49 CFR 193.2229  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

(a) Each cargo transfer system must have— (1) A means of safely depressurizing and venting that system before disconnection; (2) A means to provide for safe vapor displacement during transfer; (3) Transfer piping, pumps, and compressors located or protected by suitable barriers so that they are s

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2229>
- Source ID: `govinfo-cfr`
- SHA-256: `fc1eb0d2f25f48f01c0350740975195841bd4712421a459fecaad0596676f8d0`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2229`
- Related records: 0

## 29. Piping connections.

**Citation:** 49 CFR 193.2315  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

(a) Piping more than 2 inches nominal diameter must be joined by welding, except that— (1) Threaded or flanged connections may be used where necessary for special connections, including connections for material transitions, instrument connections, testing, and maintenance; (2) Copper piping in non

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2315>
- Source ID: `govinfo-cfr`
- SHA-256: `e2b36aaf4e1442ab99b990b80b1262fbfb3108931f9af9cf66030d8bd6905b8d`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2315`
- Related records: 2

## 30. Gas detection.

**Citation:** 49 CFR 193.2819  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

(a) All areas determined under § 193.2805(a)(2) in which a hazard to persons or property could exist must be continuously monitored for the presence of flammable gases and vapors with fixed flammable gas detection systems provided and maintained according to the applicable requirements of ANSI/NFPA 

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2819>
- Source ID: `govinfo-cfr`
- SHA-256: `332101b0102a819f750a2e215ee2586bc6d8f92624c4a63ff8b03ae8336bbe1f`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2819`
- Related records: 6

## 31. Instrumentation for LNG storage tanks.

**Citation:** 49 CFR 193.2209  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

(a) Each LNG storage tank having a capacity over 70,000 gallons (265,000 liters) must be equipped with a sufficient number of sensing devices and personnel warning devices, as prescribed, which operate continuously while the tank is in operation to assure that each of the following conditions is not

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2209>
- Source ID: `govinfo-cfr`
- SHA-256: `8e95dd4f9c60e79601c460c652c3bafd0302f1c415fa7985bc6b9c036a85e180`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2209`
- Related records: 4

## 32. Fire equipment.

**Citation:** 49 CFR 193.2817  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

(a) Each operator shall determine: (1) The types and sizes of fires that may reasonably be expected to occur within and adjacent to each LNG plant that could affect the safety of components; and (2) The foreseeable consequences of these fires, including the failure of components or buildings due to

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2817>
- Source ID: `govinfo-cfr`
- SHA-256: `86155f56b7deee995c9505d682a02606efaeeb1871981e1f9054e7825f03bc1d`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2817`
- Related records: 4

## 33. Seismic investigation and design forces.

**Citation:** 49 CFR 193.2061  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 1999-10-01 / Not stated

(a) Except for shop fabricated storage tanks of 70,000 gallons (265,000 liters) or less capacity mounted within 2 feet of the ground, if an LNG facility is located at a site in Zone 0 or 1 of the “Seismic Risk Map of the United States,” UBC, each operator shall determine, based on a study of faults,

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-1999-title49-vol3/CFR-1999-title49-vol3-sec193-2061>
- Source ID: `govinfo-cfr`
- SHA-256: `f59ec4332f793d324ad2f529fa2376e0897840ef56108243f1ee4e359904c975`
- Retrieved: 2026-08-12T01:41:23.231Z
- Document slug: `49-cfr-193-2061`