## 1. Rated capacity.

**Citation:** 49 CFR 178.352-2  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 2003-10-01 / Not stated

(a) Rated capacity as marked (see § 178.352-6). Not less than 55 gallons nor more than 110 gallons for the outer steel drum. Not more than 17.74 L for the inner vessel. (b) The authorized maximum gross weight of the package is 160 kg (350 pounds) for sizes not over 210 L (55 gallons) or 220 kg (480

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-2003-title49-vol2/CFR-2003-title49-vol2-sec178-352-2>
- Source ID: `govinfo-cfr`
- SHA-256: `a602fcb6fd8f62d1be91368852e3f39b036975db9c8bf5f54db64534d3268efb`
- Retrieved: 2026-08-13T06:37:29.399Z
- Document slug: `49-cfr-178-352-2`
- Related records: 0

## 2. Purpose and scope.

**Citation:** 49 CFR 178.600  
**Type / status:** regulation / current  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 2026-08-18 / Not stated

\[Amdt. 178-97, 55 FR 52717, Dec. 21, 1990, as amended by Amdt. 178-99, 58 FR 51534, Oct. 1, 1993\]

### Provenance

- Official: Yes
- Source: <https://www.ecfr.gov/on/2026-08-18/title-49/section-178.600>
- Source ID: `ecfr`
- SHA-256: `aaa50f88d52003323afdead9d8b7b1fb294b3aa0db6f2319fbe79e529b8902ae`
- Retrieved: 2026-08-20T05:46:20.151Z
- Document slug: `49-cfr-178-600`
- Related records: 11

## 3. Minimum thickness of shells and heads.

**Citation:** 49 CFR 178.270-5  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 2005-10-01 / Not stated

(a) For the purposes of this section, mild steel is steel with a guaranteed minimum tensile strength of 37 decanewtons per square millimeter (53,650 p.s.i.) and a guaranteed elongation of 27 percent or greater. (b) Except as otherwise provided in this subchapter, the shell and heads of each portabl

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-2005-title49-vol2/CFR-2005-title49-vol2-sec178-270-5>
- Source ID: `govinfo-cfr`
- SHA-256: `a72535af33cb3d590b3a15a6795a52daad2cd88e50b63c28eb151810d9a2bcac`
- Retrieved: 2026-08-13T06:37:34.028Z
- Document slug: `49-cfr-178-270-5`
- Related records: 0

## 4. Materials of construction.

**Citation:** 49 CFR 178.362-2  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 2003-10-01 / Not stated

(a) The general configuration of the wooden protective jacket must be a hollow cylindrical shell constructed of one-piece discs and rings of plywood or solid hardwood reinforced with steel rods. (1) The specification 20WC-2 must be additionally completely encased, snugly fit, within an 18-gauge ste

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-2003-title49-vol2/CFR-2003-title49-vol2-sec178-362-2>
- Source ID: `govinfo-cfr`
- SHA-256: `384392034ec7a4930ec7571294db3044dd0731fea602ee32bbfcce0f526c61b9`
- Retrieved: 2026-08-13T06:37:29.399Z
- Document slug: `49-cfr-178-362-2`
- Related records: 0

## 5. Pressure and vacuum relief devices.

**Citation:** 49 CFR 178.270-11  
**Type / status:** regulation / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective / published:** 2005-10-01 / Not stated

(a) Relief devices required. Each portable tank, or each independent compartment of a portable tank, must be fitted with pressure relief devices in accordance with the following: (1) Each portable tank, or each independent compartment of a portable tank, with a capacity of more than 1893 L (500 gal

### Provenance

- Official: Yes
- Source: <https://www.govinfo.gov/app/details/CFR-2005-title49-vol2/CFR-2005-title49-vol2-sec178-270-11>
- Source ID: `govinfo-cfr`
- SHA-256: `b28e5764462d24f32b62fa34ac2916b84c3c66da33efa04ec0ff04a2a877c1e7`
- Retrieved: 2026-08-13T06:37:34.028Z
- Document slug: `49-cfr-178-270-11`
- Related records: 0