## 1. Pipeline Safety: Areas Unusually Sensitive to Environmental Damage

**Citation:** 65 FR 80530  
**Type / status:** rulemaking / historical  
**Agency:** Research and Special Programs Administration  
**Effective / published:** 2001-02-20 / 2000-12-21

This final rule defines drinking water and ecological areas that are unusually sensitive to environmental damage if there is a hazardous liquid pipeline release. We refer to these areas as unusually sensitive areas (USAs). RSPA created this definition through a series of public workshops, pilot testing, a technical review of the pilot test results, and extensive collaboration with a wide-range of federal, state, public, and industry stakeholders. This final rule does not require specific action by pipeline operators but will be used in existing and future regulations.

### Provenance

- Official: Yes
- Source: <https://www.federalregister.gov/documents/2000/12/21/00-31756/pipeline-safety-areas-unusually-sensitive-to-environmental-damage>
- Source ID: `federal-register`
- SHA-256: `e4bbd86eb27cd826160074ba5e8c8af618ecffd8254fe6eee7278d7ceacb1016`
- Retrieved: 2026-08-20T06:04:51.294Z
- Document slug: `federal-register-00-31756`
- Related records: 9

## 2. Pipeline Safety: Areas Unusually Sensitive to Environmental Damage

**Citation:** 66 FR 9532  
**Type / status:** rulemaking / historical  
**Agency:** Research and Special Programs Administration  
**Effective / published:** 2001-02-20 / 2001-02-08

FR 80530.

### Provenance

- Official: Yes
- Source: <https://www.federalregister.gov/documents/2001/02/08/01-3214/pipeline-safety-areas-unusually-sensitive-to-environmental-damage>
- Source ID: `federal-register`
- SHA-256: `51331ea20f53bdf29aa98cf8283c13f9ed2733d0c19c6a8abf57f538a39ec55f`
- Retrieved: 2026-08-20T06:04:51.294Z
- Document slug: `federal-register-01-3214`
- Related records: 0

## 3. NTSB Safety Recommendation P-87-023

**Citation:** P-87-023  
**Type / status:** guidance / guidance  
**Agency:** National Transportation Safety Board  
**Effective / published:** 1987-09-09 / 1987-09-09

THE NTSB RECOMMENDS THAT THE OFFICE OF PIPELINE SAFETY: REVISE 49 CFR PARTS 192 AND 195 TO INCLUDE OPERATIONAL BASED CRITERIA FOR DETERMINING SAFE SERVICE INTERVALS FOR PIPE LINES BETWEEN HYDROSTATIC RETESTS. (Supersedes P-78-058)

### Provenance

- Official: Yes
- Source: <https://data.ntsb.gov/carol-main-public/sr-details/P-87-023>
- Source ID: `ntsb-pipeline`
- SHA-256: `c950b9fa13e0ba916c6a1cb7ff6d963a240af20f5b13019344b1f584fa4a9988`
- Retrieved: 2026-08-20T04:57:24.741Z
- Document slug: `ntsb-recommendation-p-87-023`
- Related records: 4

## 4. NTSB Safety Recommendation P-87-026

**Citation:** P-87-026  
**Type / status:** guidance / guidance  
**Agency:** National Transportation Safety Board  
**Effective / published:** 1987-09-09 / 1987-09-09

THE NTSB RECOMMENDS THAT THE OFFICE OF PIPELINE SAFETY: OBTAIN SUFFICIENT DATA ON LOW FREQUENCY, ELECTRIC RESISTANCE WELDED PIPE AND DETERMINE IF ITS CONTINUED USE PRESENTS AN UNREASONABLE HAZARD TO PUBLIC SAFETY AND TAKE APPROPRIATE REGULATORY ACTION FOR IDENTIFIED DEFICIENCIES.

### Provenance

- Official: Yes
- Source: <https://data.ntsb.gov/carol-main-public/sr-details/P-87-026>
- Source ID: `ntsb-pipeline`
- SHA-256: `cb229a7bc0fc4be5648fa4c3b3d822677e354f9cd53d9f03b35821a18835e469`
- Retrieved: 2026-08-20T04:57:24.741Z
- Document slug: `ntsb-recommendation-p-87-026`
- Related records: 1

## 5. NTSB Safety Recommendation P-95-001

**Citation:** P-95-001  
**Type / status:** guidance / guidance  
**Agency:** National Transportation Safety Board  
**Effective / published:** 1995-02-07 / 1995-02-07

THE NTSB RECOMMENDS THAT THE RSPA: EXPEDITE REQUIREMENTS FOR INSTALLING AUTOMATIC- OR REMOTE-OPERATED MAINLINE VALVES ON HIGH-PRESSURE PIPELINES IN URBAN AND ENVIRONMENTALLY SENSITIVE AREAS TO PROVIDE FOR RAPID SHUTDOWN OF FAILED PIPELINE SEGMENTS. (Supersedes P-87-022)

### Provenance

- Official: Yes
- Source: <https://data.ntsb.gov/carol-main-public/sr-details/P-95-001>
- Source ID: `ntsb-pipeline`
- SHA-256: `b638d786d75add453a47b16abcbf82b4be92e8a08989974c54e7158a8d20c348`
- Retrieved: 2026-08-20T04:57:24.741Z
- Document slug: `ntsb-recommendation-p-95-001`
- Related records: 5

## 6. NTSB Safety Recommendation P-87-005

**Citation:** P-87-005  
**Type / status:** guidance / guidance  
**Agency:** National Transportation Safety Board  
**Effective / published:** 1987-03-24 / 1987-03-24

THE NTSB RECOMMENDS THAT THE RESEARCH AND SPECIAL PROGRAM ADMINISTRATION, U.S. DEPARTMENT OF TRANSPORTATION: ESTABLISH CRITERIA FOR USE BY OPERATORS OF PIPELINES IN DETERMINING THE FREQUENCY FOR PERFORMING INSPECTIONS AND TESTS CONDUCTED TO DETERMINE THE APPROPRIATENESS OF ESTABLISHED MAXIMUM ALLOWABLE OPERATING PRESSURES.

### Provenance

- Official: Yes
- Source: <https://data.ntsb.gov/carol-main-public/sr-details/P-87-005>
- Source ID: `ntsb-pipeline`
- SHA-256: `bbceba603c0b36f50783fcd37c9b9d9e57b0f34c9d9d276e9bfb78d3abc7da77`
- Retrieved: 2026-08-20T04:57:24.741Z
- Document slug: `ntsb-recommendation-p-87-005`
- Related records: 4

## 7. NTSB Safety Recommendation P-87-004

**Citation:** P-87-004  
**Type / status:** guidance / guidance  
**Agency:** National Transportation Safety Board  
**Effective / published:** 1987-03-24 / 1987-03-24

THE NTSB RECOMMENDS THAT THE RESEARCH AND SPECIAL PROGRAM ADMINISTRATION, U.S. DEPARTMENT OF TRANSPORTATION: REQUIRE OPERATIONS OF BOTH GAS AND LIQUID TRANSMISSION PIPELINES TO PERIODICALLY DETERMINE THE ADEQUACY OF THEIR PIPELINES TO OPERATE AT ESTABLISHED MAXIMUM ALLOWABLE PRESSURES BY PERFORMING INSPECTIONS OR TESTS CAPABLE OF IDENTIFYING CORROSION-CAUSED AND OTHER TIME-DEPENDENT DAMAGES THAT MAY BE DETRIMENTAL TO

### Provenance

- Official: Yes
- Source: <https://data.ntsb.gov/carol-main-public/sr-details/P-87-004>
- Source ID: `ntsb-pipeline`
- SHA-256: `c4ab0382fe5a072c1b05bd17e2c766452fad82a3f9231dbecd717741511a7d6d`
- Retrieved: 2026-08-20T04:57:24.741Z
- Document slug: `ntsb-recommendation-p-87-004`
- Related records: 4