(a) Before being installed for use by a customer, every gas service meter, whether new, repaired, or removed from service for any cause shall be in good order and, except as provided in paragraph (b) of this rule, shall be adjusted to be correct to within one percent when passing gas at 20 percent o

## Document text

(a) Before being installed for use by a customer, every gas service meter, whether
new, repaired, or removed from service for any cause shall be in good order and,
except as provided in paragraph (b) of this rule, shall be adjusted to be correct to
within one percent when passing gas at 20 percent of its rated capacity at one-
half inch water column differential.
(b) New rotary displacement type gas service meters in sizes having a rated
capacity of more than 5,000 cubic feet per hour at a differential not to exceed two
inches water column shall be tested and calibrated at the factory in accordance
with recognized and accepted practices. These meters shall also be adjusted to
be correct within two percent slow and one percent fast when passing gas at ten
percent of its rated capacity and shall be adjusted to be correct within one
percent slow and one percent fast when passing gas at 100 percent of its rated
capacity. Prior to reuse of a rotary displacement type meter that has been
removed from service, the meter shall pass the same testing criteria as a new
meter.

## Provenance

- Official: Yes
- Source: <https://www.sos.state.co.us/CCR/DisplayRule.do?action=ruleinfo&ruleId=2260&deptID=18&agencyID=96&deptName=Department%20of%20Regulatory%20Agencies&agencyName=Public%20Utilities%20Commission&seriesNum=4%20CCR%20723-4>
- Source ID: `co-sos-ccr`
- SHA-256: `ac0aaff5577f864958fb153ed096d48c48eb7dd71ae46a82581a284e6c6915d5`
- Retrieved: 2026-08-12T04:36:48.096Z
- Exported: 2026-08-24T11:55:07.562Z
- Document slug: `co-ccr-4-723-4-4302`

### Source metadata

```json
{
  "jurisdiction": "US-CO",
  "code": "4 CCR 723-4",
  "ruleKey": "4302",
  "pipelineScope": "colorado-jurisdictional-gas-utilities",
  "legalScope": "Current 4 CCR 723-4 rules regulating Colorado jurisdictional gas utilities and gas master-meter operators, including construction, operation, system safety, gas infrastructure planning, metering, service, and enforcement provisions. This is an adjacent gas-utility corpus, not a replacement for the repealed dedicated 4900-series pipeline-safety rules.",
  "applicabilityCaveat": "Part 4 applies according to Colorado Public Utilities Commission jurisdiction and each rule's scope. The former dedicated pipeline-safety rules 4900 through 4975 are reserved after repeal; this connector does not represent them as current. Part 4 does not replace federal pipeline-safety requirements, determine whether a facility is interstate or intrastate, or resolve operator-specific orders, waivers, tariffs, or later rulemaking.",
  "references": [],
  "ruleInfoUrl": "https://www.sos.state.co.us/CCR/DisplayRule.do?action=ruleinfo&ruleId=2260&deptID=18&agencyID=96&deptName=Department%20of%20Regulatory%20Agencies&agencyName=Public%20Utilities%20Commission&seriesNum=4%20CCR%20723-4",
  "pucRulesUrl": "https://puc.colorado.gov/gasrulesandregulations",
  "ruleVersionId": "12549",
  "editionEffectiveOn": "2026-06-14",
  "publicationStatus": "The Colorado Secretary of State identifies the source as the official publication of state administrative rules. The edition date applies to the compiled rule version and is not represented as the effective date of every provision.",
  "rights": "Official state rule text is preserved with attribution and source links. Public accessibility does not imply rights in agency marks, third-party material, or incorporated standards; commercial redistribution requires review.",
  "region": "CO"
}
```