# Sectionalizing block valves

**Citation:** Mich. Admin. Code R 460.20407  
**Type / status:** regulation / current  
**Agency:** Michigan Public Service Commission  
**Effective:** 2026-05-04  
**Published:** Not stated

Rule 407. In addition to the requirements in 49 C.F.R. §192.179, which is adopted by reference in R 460.20606, an operator of pipeline facilities used in the transportation of sour gas shall comply with all of the following requirements for any portion of the pipeline that contains more than 10 poun

## Document text

Rule 407. In addition to the requirements in 49 C.F.R. §192.179, which is adopted by reference in R 460.20606, an operator of pipeline facilities used in the transportation of sour gas shall comply with all of the following requirements for any portion of the pipeline that contains more than 10 pounds of H2S per mile, with the weight calculated according to the formula: PxVxMxH W=9.318x10-8-------------------------, where: T W=Weight of H2S in pounds per mile of pipe, P=Absolute pressure in pounds per square inch, V=Volume of one mile of pipe in cubic feet, M=Molecular weight of the gas in grams per mole, H= Quantity of H2S in the gas in parts per million, T=Temperature in degrees Rankine:

(a) Sectionalizing block valves must be installed and located so that each point on the pipeline is within 3 miles of a sectionalizing block valve with a block valve located at each end of the pipeline.

(b) A pipeline must incorporate block valve automation so that block valves will automatically close upon the registering of low pressure readings. The system must be designed to operate even in the event of a power failure or malfunction of electronic devices and must be designed to fail in a closed position.

(c) A pipeline must incorporate a supervisory control and data acquisitions (SCADA) system that complies with all of the following provisions:

(i) Is monitored by the operator to ensure appropriate response to emergencies.

(ii) Is programmed to automatically close block valves based on operating data gathered at each metering site and at each automated block valve.

(iii) Automatically closes the upstream and downstream sectionalizing block valves surrounding any sectionalizing block valve that is in an alarm condition.

(iv) Allows the operator monitoring the SCADA system to close, but not open, any or all of the block valves and metering points.

(d) H2S sensors must be located at all sectionalizing block valve sites. The sensors must provide a warning to the SCADA system at H2S levels of 10 ppm and shall close the block valve at H2S levels of 30 ppm.

(e) Control valves must be installed at appropriate locations at well sites or laterals to automatically shut off the flow of gas into the pipeline in the event of a line break or over pressure conditions.

History: 2003 AACS; 2009 AACS; 2010 AACS; 2019 AACS.

## Provenance

- Official: Yes
- Source: <https://ars.apps.lara.state.mi.us/AdminCode/DownloadAdminCodeFile?FileName=R%20460.20101%20to%20R%20460.20606.pdf>
- Source ID: `mi-ars-gas-safety`
- SHA-256: `603dfa43f9de0910bdfe06faeb95275a91b8595ca33dc44a699fa4f93d757e96`
- Retrieved: 2026-08-20T08:33:06.234Z
- Exported: 2026-08-22T14:48:14.432Z
- Document slug: `mi-admin-code-r-460-20407`

### Source metadata

```json
{
  "jurisdiction": "US-MI",
  "rule": "R 460.20407",
  "part": "4",
  "partTitle": "SOUR GAS PIPELINES",
  "edition": 27,
  "editionEffectiveOn": "2026-05-04",
  "corpusScope": "complete-current-dedicated-michigan-gas-safety-standards",
  "inventoryCount": 81,
  "currentRuleCount": 78,
  "references": [
    {
      "citation": "49 CFR 192.179",
      "referenceType": "federal-regulation-section",
      "url": "https://www.ecfr.gov/current/title-49/section-192.179"
    },
    {
      "citation": "R 460.20606",
      "referenceType": "michigan-administrative-rule",
      "url": "https://ars.apps.lara.state.mi.us/AdminCode/DownloadAdminCodeFile?FileName=R%20460.20101%20to%20R%20460.20606.pdf"
    }
  ],
  "federalReferences": [
    {
      "citation": "49 CFR 192.179",
      "referenceType": "federal-regulation-section",
      "url": "https://www.ecfr.gov/current/title-49/section-192.179"
    }
  ],
  "stateReferences": [
    {
      "citation": "R 460.20606",
      "referenceType": "michigan-administrative-rule",
      "url": "https://ars.apps.lara.state.mi.us/AdminCode/DownloadAdminCodeFile?FileName=R%20460.20101%20to%20R%20460.20606.pdf"
    }
  ],
  "statutoryAuthority": [
    "1969 PA 165",
    "MCL 483.152"
  ],
  "hazardousLiquidCoverage": false,
  "scopeCaveat": "This connector is the complete current dedicated Michigan Administrative Code Gas Safety corpus published by ARS/MOAHR from R 460.20101 through R 460.20606. It does not claim all Michigan utility, siting, excavation-damage-prevention, well, environmental, federal, local, or Commission order law. Three headings expressly marked rescinded are retained only in the verified inventory. The MPSC pipeline-safety program does not regulate hazardous-liquid pipelines, and this corpus must not be used to imply that it does.",
  "applicabilityCaveat": "Applicability depends on the definitions and exclusions in R 460.20101 and R 460.20102, MPSC jurisdiction, gas and facility type, intrastate or interstate status, gathering-line classification, operator status, waivers, federal preemption, and rule-specific conditions. MPSC inspects jurisdictional intrastate gas systems and acts as an interstate agent for inspections and investigations; PHMSA retains interstate enforcement authority. MPSC expressly states that its pipeline-safety program lacks hazardous-liquid-pipeline jurisdiction.",
  "incorporationCaveat": "The rules adopt specified editions of 49 CFR parts 40, 191, 192, and 199 and named API, ASME, and NACE/ISO standards. References metadata does not reproduce incorporated material, update a fixed edition, determine whether a provision is superseded, or grant rights in third-party standards. Verify the exact edition and any Michigan additions, exceptions, or superseding language in the current official sources.",
  "publicationCaveat": "The rule text comes from the current ARS/MOAHR Michigan Administrative Code download. The MPSC identifies it as the 27th edition effective May 4, 2026. Historical Guide to the Michigan Gas Safety Standards files, including the 25th edition guide, are not current rule artifacts and are not used by this connector.",
  "rights": "Michigan administrative rule text is official legal material and is preserved with ARS/MOAHR and MPSC attribution. Public availability does not resolve rights in agency seals, site presentation, incorporated federal compilations, API, ASME, NACE/ISO standards, forms, or other third-party material; downstream redistribution requires separate rights review.",
  "rightsReviewRequired": true,
  "region": "MI"
}
```