Transmission and Distribution of Gas. (a) No welder or welding operator whose qualification is based on nondestructive testing may weld compressor station pipe and components.

(b) No welder or welding operator may weld with a particular welding process unless, within the preceding six calendar months, he has engaged in welding with that process.

(c) A welder qualified under section 255.227(a) 

## Document text

(a) No welder or welding operator whose qualification is based on nondestructive testing may weld compressor station pipe and components.

(b) No welder or welding operator may weld with a particular welding process unless, within the preceding six calendar months, he has engaged in welding with that process.

(c) A welder qualified under section 255.227(a) of this Part:

(1) may not weld on pipe to be operated at a pressure of 125 psig or more unless within the preceding 6 calendar months the welder has had one weld tested and found acceptable under section 6, 9, 12 or Appendix A of API Std 1104 (as described in section 10.3 of this Title). Alternatively, welders or welding operators may maintain an ongoing qualification status by performing welds tested and found acceptable under the above acceptance criteria at least twice each calendar year, but at intervals not exceeding 7½ months. A welder or welding operator qualified under an earlier edition of a standard listed in section 10.3 of this Title may weld, but may not requalify under that earlier edition; and

(2) may not weld on pipe to be operated at a pressure less than 125 psig unless the welder or welding operator is tested in accordance with paragraph (c)(1) of this section or re-qualifies under paragraph (d)(1) or (2) of this section.

(d) A welder qualified under section 255.227(b) of this Part may not weld unless:

(1) within the preceding 15 calendar months, the welder has requalified, except that the welder or welding operator must requalify at least once each calendar year; or

(2) within the preceding 7½ calendar months, but at least twice each calendar year, the welder or welding operator has had:

(i) a production weld cut out, tested and found acceptable in accordance with the qualifying test; or

(ii) a production weld tested and found acceptable under section 6 of API Standard 1104 (as described in section 10.3 of this Title); or

(iii) for welders who work only on service lines two inches (51 millimeters) or smaller in diameter, two sample welds tested and found acceptable in accordance with the test in section III of Appendix 14-F to this Title.

(e) Welder requalification tests shall be required if there is good cause to question a welder's ability.

## Provenance

- Official: Yes
- Source: <https://govt.westlaw.com/nycrr/Document/I505cbdeecd1711dda432a117e6e0f345?viewType=FullText&originationContext=documenttoc&transitionType=CategoryPageItem&contextData=(sc.Default)>
- Source ID: `ny-dps-nycrr`
- SHA-256: `e60577c51068a07915aa86a4c051c55c441b86de7966b32fdaebbd5c0b29aaf8`
- Retrieved: 2026-08-12T06:20:40.894Z
- Exported: 2026-08-25T02:08:35.174Z
- Document slug: `ny-nycrr-255-229`

### Source metadata

```json
{
  "jurisdiction": "US-NY",
  "title": 16,
  "part": "255",
  "partTitle": "Transmission and Distribution of Gas",
  "scopeKind": "gas-pipeline-safety",
  "tocPath": [
    "Part 255 Transmission and Distribution of Gas",
    "Welding of Steel in Pipelines"
  ],
  "legalScope": "Complete current terminal legal unit exposed by the DPS-designated Title 16 NYCRR pipeline-safety part inventory.",
  "applicabilityCaveat": "Applicability depends on the part and section, Commission jurisdiction, commodity and facility type, intrastate or interstate status, operator and activity, exemptions, waivers, federal preemption, Commission orders, and incorporated law. DPS inspects portions of interstate systems for PHMSA, but PHMSA retains federal enforcement authority. DPS states that all jurisdictional Part 256 gas-holder and Part 257 LPG-plant facilities have been decommissioned even though those regulations remain unrepealed.",
  "incorporationCaveat": "These parts incorporate or rely on federal pipeline regulations, federal and New York statutes, Commission rules and orders, and privately authored technical standards. Part 10 supplies incorporation details. References metadata preserves explicit citations but does not reproduce external material, determine licensing rights, or decide whether a particular incorporation is static or dynamic.",
  "publicationCaveat": "The New York Department of Public Service identifies these eleven Title 16 NYCRR parts as its state pipeline-safety regulations and links to the public DOS/Westlaw NYCRR reading copy. That site labels the online text unofficial and directs users needing evidentiary accuracy to the Official NYCRR maintained by the Department of State Division of Administrative Rules. Each section's 'Current through' date is the most recent official NYCRR supplement covering that section, not a uniform corpus-wide amendment date.",
  "rights": "New York government-edict text is preserved with DPS, Department of State, and publisher attribution. The public reading site's presentation and enhancements, agency marks, forms, annotations, and incorporated federal or privately authored standards require separate rights review; this connector does not claim rights in those materials.",
  "rightsReviewRequired": true,
  "currentThrough": "2024-05-31",
  "historyEvents": "No event is emitted because the section reading copy does not supply an explicit adoption, filing, or effective-date history.",
  "publisherCitation": "16 CRR-NY 255.229",
  "identityAnomaly": null,
  "references": [
    {
      "citation": "16 NYCRR 255.227",
      "referenceType": "new-york-administrative-code",
      "url": "https://govt.westlaw.com/nycrr/Document/I505cbdebcd1711dda432a117e6e0f345?viewType=FullText&originationContext=documenttoc&transitionType=CategoryPageItem&contextData=(sc.Default)"
    },
    {
      "citation": "16 NYCRR 10.3",
      "referenceType": "new-york-administrative-code",
      "url": "https://govt.westlaw.com/nycrr/Document/I50525ddbcd1711dda432a117e6e0f345?viewType=FullText&originationContext=documenttoc&transitionType=CategoryPageItem&contextData=(sc.Default)"
    }
  ],
  "region": "NY"
}
```