# 753-3.6 Verification of underground facilities.

**Citation:** 16 NYCRR 753-3.6  
**Type / status:** regulation / current  
**Agency:** New York State Public Service Commission  
**Effective:** Not stated  
**Published:** Not stated

Protection of Underground Facilities. Where an underground facility has been staked, marked or otherwise designated by the operator and the tolerance zone overlaps with any part of the work area, or the projected line of a bore/directional drill intersects the tolerance zone, the excavator shall verify the precise location, type, size, direction of run and depth of such underground facility or i

## Document text

Where an underground facility has been staked, marked or otherwise designated by the operator and the tolerance zone overlaps with any part of the work area, or the projected line of a bore/directional drill intersects the tolerance zone, the excavator shall verify the precise location, type, size, direction of run and depth of such underground facility or its encasement. Verification shall be completed before the excavation or demolition is commenced or shall be performed as the work progresses.

(a) Powered or mechanized equipment may be used within the tolerance zone for removal of pavement or masonry but only to the depth of such pavement or masonry.

(1) Below the depth of pavement or masonry, powered equipment may be used in the tolerance zone prior to the verification of the location of facilities when agreed to in writing by the affected operator(s).

(2) Operators, or their agents and contractors working under their direction, may use powered equipment to locate their own facilities within the tolerance zone.

(b) The verification of underground facilities furnishing gas or liquid petroleum products shall be accomplished by the excavator by exposing the underground facility or its encasement to view by means of hand dug test holes at one or more points where the work area and tolerance zone overlap, or more points as designated by the operators of such facilities.

(c) The verification of underground facilities other than those furnishing gas or liquid petroleum products shall be performed at one or more points for each such underground facility as may be required by the operator. Verification shall be accomplished by exposing the underground facility or its encasement to view by hand dug test holes or by other means mutually agreed to by the excavator and operator.

## Provenance

- Official: Yes
- Source: <https://govt.westlaw.com/nycrr/Document/I50698f2ccd1711dda432a117e6e0f345?viewType=FullText&originationContext=documenttoc&transitionType=CategoryPageItem&contextData=(sc.Default)>
- Source ID: `ny-dps-nycrr`
- SHA-256: `fcffd876d42340697894bc1114fd96c00fef2ce6f413bbacac2d3923c4abc75e`
- Retrieved: 2026-08-12T06:20:40.894Z
- Exported: 2026-08-24T19:18:50.824Z
- Document slug: `ny-nycrr-753-3-6`

### Source metadata

```json
{
  "jurisdiction": "US-NY",
  "title": 16,
  "part": "753",
  "partTitle": "Protection of Underground Facilities",
  "scopeKind": "underground-damage-prevention",
  "tocPath": [
    "Part 753 Protection of Underground Facilities",
    "Subpart 753-3 Duties of Excavators"
  ],
  "legalScope": "Complete current terminal legal unit exposed by the DPS-designated Title 16 NYCRR pipeline-safety part inventory.",
  "applicabilityCaveat": "Applicability depends on the part and section, Commission jurisdiction, commodity and facility type, intrastate or interstate status, operator and activity, exemptions, waivers, federal preemption, Commission orders, and incorporated law. DPS inspects portions of interstate systems for PHMSA, but PHMSA retains federal enforcement authority. DPS states that all jurisdictional Part 256 gas-holder and Part 257 LPG-plant facilities have been decommissioned even though those regulations remain unrepealed.",
  "incorporationCaveat": "These parts incorporate or rely on federal pipeline regulations, federal and New York statutes, Commission rules and orders, and privately authored technical standards. Part 10 supplies incorporation details. References metadata preserves explicit citations but does not reproduce external material, determine licensing rights, or decide whether a particular incorporation is static or dynamic.",
  "publicationCaveat": "The New York Department of Public Service identifies these eleven Title 16 NYCRR parts as its state pipeline-safety regulations and links to the public DOS/Westlaw NYCRR reading copy. That site labels the online text unofficial and directs users needing evidentiary accuracy to the Official NYCRR maintained by the Department of State Division of Administrative Rules. Each section's 'Current through' date is the most recent official NYCRR supplement covering that section, not a uniform corpus-wide amendment date.",
  "rights": "New York government-edict text is preserved with DPS, Department of State, and publisher attribution. The public reading site's presentation and enhancements, agency marks, forms, annotations, and incorporated federal or privately authored standards require separate rights review; this connector does not claim rights in those materials.",
  "rightsReviewRequired": true,
  "currentThrough": "2023-02-28",
  "historyEvents": "No event is emitted because the section reading copy does not supply an explicit adoption, filing, or effective-date history.",
  "publisherCitation": "16 CRR-NY 753-3.6",
  "identityAnomaly": null,
  "references": [],