# MAGELLAN TERMINALS HOLDINGS, LP — Warning Letter

**Citation:** CPF 120126001W  
**Type / status:** enforcement / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective:** Not stated  
**Published:** 2012-04-06

CLOSED warning letter citing 195.404(c)(3), 195.589(c).

## Document text

Warning Letter involving MAGELLAN TERMINALS HOLDINGS, LP. PHMSA's enforcement data identifies the cited regulations as 195.404(c)(3),  195.589(c). The case was opened on 2012-04-06 and is reported as closed as of 2012-04-06. Open the official case record for notices, responses, orders, and the latest status.

Official case documents:

120126001W_Operator Response_06252012.pdf: https://primis.phmsa.dot.gov/enforcement-documents/120126001W/120126001W_Operator%20Response_06252012.pdf

120126001W_Warning Letter_04062012.pdf: https://primis.phmsa.dot.gov/enforcement-documents/120126001W/120126001W_Warning%20Letter_04062012.pdf

120126001W_Warning Letter_04062012_text.pdf: https://primis.phmsa.dot.gov/enforcement-documents/120126001W/120126001W_Warning%20Letter_04062012_text.pdf

120126001W_Warning Letter_04062012_text.pdf

U.S. Department 820 Bear Tavern Road, Suite 103
Of Transportation West Trenton, NJ 08628
Pipeline and 609.989.2171
Hazardous Materials
Safety Administration
WARNING LETTER
OVERNIGHT EXPRESS MAIL
April 06, 2012
Michael C. Pearson
Vice President Technical Services
Magellan Midstream Partners, L.P.
One Williams Center
Tulsa, OK 74172
CPF 1-2012-6001W
Dear Mr. Pearson:
On October 26, 2010, representatives of the Pipeline and Hazardous Materials Safety Administration
(PHMSA) pursuant to Chapter 601 of 49 United States Code inspected Magellan Midstream Partners,
L.P.’s asset, Magellan Terminal Holdings, L.P.’s (Magellan), in New Haven, Connecticut.
As a result of the inspection, it appears that you have committed probable violations of the Pipeline Safety
Regulations, Title 49, Code of Federal Regulations. The items inspected and the probable violations are:
1. §195.404 Maps and Records.
(c) Each operator shall maintain the following records for the periods specified;
(3) A record of each inspection and test required by this subpart shall be maintained for at
least 2 years or until the next inspection or test is performed, whichever is longer.
Magellan failed to maintain records of inspections required by §195.432(b) for at least 2 years.
Magellan’s Monthly Tank Inspection records noted the general condition of paint coating on Breakout
Tank # 3H was inadequate from the period 2008 to 2010.
• At the time of the PHMSA inspection, the PHMSA representative asked if the deficiencies had
been remediated.
• The Magellan representative stated that the records were completed incorrectly and based on their
procedures, the general condition of the paint coating should have been stated as “adequate” and
therefore no remediation was required.
• Therefore, the records were incorrect.
Incorrect records do not provide an adequate basis for taking appropriate actions to ensure pipeline
integrity.



CPF 1-2012-6001W
2. §195.589 What corrosion control information do I have to maintain?
(c) You must maintain a record of each analysis, check, demonstration, examination,
inspection, investigation, review, survey, and test required by this subpart in sufficient detail to
demonstrate the adequacy of corrosion control measures or that corrosion requiring control
measures does not exist. You must retain these records for at least 5 years, except that records
related to Secs. 195.569, 195.573(a) and (b), and 195.579(b)(3) and (c) must be retained for as
long as the pipeline remains in service.
Magellan failed to maintain records of atmospheric corrosion inspections required by §195.583(a) in
sufficient detail to demonstrate the adequacy of corrosion control measures.
At the time of the PHMSA inspection, Magellan provided the PHMSA representatives with copies of
records of atmospheric corrosion inspections for the period of 2005 to 2008. According to Magellan, it
used a grading system for atmospheric corrosion inspections. The records showed inconsistencies in
regards to the grade and the condition of the interface areas. The following information comes from
Magellan’s atmospheric corrosion inspections records:
Grade - Condition of
interface area
Location Date
1-G 50% rusted Adequate Tank 11H piping in Area 10.001 September 26, 2005
1-G 50% rusted Inadequate Station 55+84 Humphrey St. Bridge November 11, 2008
1-G 50% rusted Adequate Station 77+87 Blatchley St. Bridge to
Shoreline Wall
November 11, 2008
4-9G<16% rusted Inadequate Station 15+06 Chapel St Bridge September 26, 2005
4-9G<16% rusted Adequate Humphrey St Bridge September 26, 2005
Due to the inconsistencies in the records, Magellan did not comply with §195.589(c).
Under 49 United States Code, § 60122, you are subject to a civil penalty not to exceed $100,000 for each
violation for each day the violation persists up to a maximum of $1,000,000 for any related series of
violations. We have reviewed the circumstances and supporting documents involved in this case, and
have decided not to conduct additional enforcement action or penalty assessment proceedings at this time.
We advise you to correct the item(s) identified in this letter. Failure to do so will result in Magellan being
subject to additional enforcement action.
No reply to this letter is required. If you choose to reply, in your correspondence please refer to CPF 1-
2012-6001W. Be advised that all material you submit in response to this enforcement action is subject to
being made publicly available. If you believe that any portion of your responsive material qualifies for
confidential treatment under 5 U.S.C. 552(b), along with the complete original document you must
provide a second copy of the document with the portions you believe qualify for confidential treatment
redacted and an explanation of why you believe the redacted information qualifies for confidential
treatment under 5 U.S.C. 552(b).
Sincerely,
Byron Coy, PE
Director, Eastern Region
Pipeline and Hazardous Materials Safety Administration
120126001W_Warning Ltr_04062012 Page 2 of 2

## Provenance

- Official: Yes
- Source: <https://primis.phmsa.dot.gov/enforcement-data/case/120126001W>
- Source ID: `phmsa-enforcement`
- SHA-256: `32fb6d595712addd6875f227fc8b5ea3ba2a40bc0fbcfe641c04dbfd44bf8c04`
- Retrieved: 2026-08-20T04:44:44.458Z
- Exported: 2026-08-22T21:42:56.032Z
- Document slug: `phmsa-enforcement-120126001w`

### Source metadata

```json
{
  "cpf": "120126001W",
  "operator": "MAGELLAN TERMINALS HOLDINGS, LP",
  "region": "Eastern",
  "pipelineType": "INTRASTATE LIQUID ONSHORE",
  "caseStatus": "CLOSED",
  "citedSections": [
    "195.404(c)(3)",
    "195.589(c)"
  ],
  "dataAsOf": "08/04/2026 12PM",
  "caseDataAsOf": "2026-08-04",
  "attachmentCount": 3,
  "attachments": [
    {
      "name": "120126001W_Operator Response_06252012.pdf",
      "url": "https://primis.phmsa.dot.gov/enforcement-documents/120126001W/120126001W_Operator%20Response_06252012.pdf",
      "bytes": 419729,
      "category": "party_submission"
    },
    {
      "name": "120126001W_Warning Letter_04062012.pdf",
      "url": "https://primis.phmsa.dot.gov/enforcement-documents/120126001W/120126001W_Warning%20Letter_04062012.pdf",
      "bytes": 1623061,
      "category": "agency_document"
    },
    {
      "name": "120126001W_Warning Letter_04062012_text.pdf",
      "url": "https://primis.phmsa.dot.gov/enforcement-documents/120126001W/120126001W_Warning%20Letter_04062012_text.pdf",
      "bytes": 33972,
      "category": "agency_document"
    }
  ],
  "extractedAgencyDocumentCount": 1,
  "attachmentPolicy": "Official attachment links are retained. Agency-issued documents may also include a verified local PDF and page-level text representation.",
  "jurisdiction": "US",
  "operatorName": "MAGELLAN TERMINALS HOLDINGS, LP"
}
```