# ROYAL ARMS GARDEN APARTMENTS — Warning Letter

**Citation:** CPF 220150002W  
**Type / status:** enforcement / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective:** Not stated  
**Published:** 2015-02-19

CLOSED warning letter citing 192.1015(a), 192.455(a), 192.481, 192.625(f), 192.721(a), 192.747(a).

## Document text

Warning Letter involving ROYAL ARMS GARDEN APARTMENTS. PHMSA's enforcement data identifies the cited regulations as 192.1015(a),  192.455(a),  192.481,  192.625(f),  192.721(a),  192.747(a). The case was opened on 2015-02-19 and is reported as closed as of 2015-02-19. Open the official case record for notices, responses, orders, and the latest status.

Official case documents:

220150002W_warning letter_02192015.pdf: https://primis.phmsa.dot.gov/enforcement-documents/220150002W/220150002W_warning%20letter_02192015.pdf

220150002W_warning letter_02192015_text.pdf: https://primis.phmsa.dot.gov/enforcement-documents/220150002W/220150002W_warning%20letter_02192015_text.pdf

220150002W_warning letter_02192015_text.pdf

WARNING LETTER
CERTIFIED MAIL - RETURN RECEIPT REQUESTED
February 19, 2015
Ms. Brenda Zopp
Royal Arms Garden Apartments LLC
1420 Balboa Ave.
Panama City, FL 32401
CPF 2-2015-0002W
Dear Ms. Zopp:
On August 13, 2014, a representative of the Pipeline and Hazardous Materials Safety
Administration (PHMSA), Southern Region, Office of Pipeline Safety (OPS), pursuant to
Chapter 601 of 49 United States Code, inspected the Royal Arms Garden Apartments natural
gas master meter system records and master meter pipeline system at the Royal Arms Garden
Apartments in Panama City, Florida.
As a result of our investigation, it appears that Royal Arms Garden Apartments has committed
probable violations of the Pipeline Safety Regulations, Title 49, Code of Federal Regulations.
The items inspected and the probable violations are as follows:
1. §192.455 External corrosion control: Buried or submerged pipelines installed after
July 31, 1971.
(a) Except as provided in paragraphs (b), (c), and (f) of this section, each buried or
submerged pipeline installed after July 31, 1971, must be protected against external
corrosion, including the following:
(1) It must have an external protective coating meeting the requirements of
§192.461.
(2) It must have a cathodic protection system designed to protect the pipeline in
accordance with this subpart, installed and placed in operation within 1 year after
completion of construction.
The Royal Arms Garden Apartments did not provide documentation demonstrating that it
had installed a cathodic protection system on its buried pipeline system.



2. §192.481 Atmospheric corrosion control: Monitoring.
Each operator must inspect each pipeline or portion of pipeline that is exposed to
atmosphere for evidence of atmospheric corrosion, as follows:
If the pipeline is located: Then the frequency of inspection is:
Onshore At least once every 3 calendar years, but with
intervals not exceeding 39 months
Offshore At least once each calendar year, but with
intervals not exceeding 15 months
The Royal Arms Garden Apartments did not present records to demonstrate that it had
inspected its onshore pipeline exposed to the atmosphere for evidence of atmospheric
corrosion at least once every 3 calendar years, but with intervals not exceeding 39 months.
3. §192.625 Odorization of gas.
…(f) To assure the proper concentration of odorant in accordance with this section,
each operator must conduct periodic sampling of combustible gases using an
instrument capable of determining the percentage of gas in air at which the odor
becomes readily detectable. Operators of master meters systems may comply with
this requirement by-
(1) Receiving written verification from their gas source that the gas has the proper
concentration of odorant; and
(2) Conducting periodic “sniff” test at the extremities of the system to confirm that
the gas contains odorant.
The Royal Arms Garden Apartments did not present records to demonstrate that it had
assured the proper concentration of odorant in its pipeline system by receiving written
verification from its gas source that the gas has the proper concentration of odorant or by
conducting periodic "sniff" tests at the extremities of the system to confirm that the gas
contains odorant.
4. §192.721 Distribution systems: Patrolling.
(a) The frequency of patrolling mains must be determined by the severity of the
conditions which could cause failure or leakage, and the consequent hazards to
public safety.
The Royal Arms Garden Apartments did not present records to demonstrate that it
conducted patrols of the pipeline system mains.
5. §192.747 Valve maintenance: Distribution systems.
(a) Each valve, the use of which may be necessary for the safe operation of a
distribution system, must be checked and serviced at intervals not exceeding 15
months, but at least once each calendar year.
2



The Royal Arms Garden Apartments did not present records to demonstrate that it
checked and serviced each valve necessary for the safe operation of its distribution system
at intervals not exceeding 15 months, but at least once each calendar year.
6. §192.1015 What must a master meter or small liquefied petroleum gas (LPG)
operator do to implement this subpart?
(a) General. No later than August 2, 2011 the operator of a master meter system or a
small LPG operator must develop and implement an IM program that includes a
written IM plan as specified in paragraph (b) of this section. The IM program for
these pipelines should reflect the relative simplicity of these types of pipelines.
The Royal Arms Garden Apartments did not present records to demonstrate that it had
developed and implemented an Integrity Management program.
Under 49 United States Code, §60122, Royal Arms Garden Apartments is subject to a civil
penalty not to exceed $200,000 per violation per day the violation persists up to a maximum
of $2,000,000 for a related series of violations. For violations occurring prior to
January 4, 2012, the maximum penalty may not exceed $100,000 per violation per day, with a
maximum penalty not to exceed $1,000,000 for a related series of violations. We have
reviewed the circumstances and supporting documents involved in this case, and have decided
not to conduct additional enforcement action or penalty assessment proceedings at this time.
We advise you to correct the items identified in this letter. Failure to do so will result in
Royal Arms Garden Apartments being subject to additional enforcement action.
No reply to this letter is required. If you choose to reply, in your correspondence please refer
to CPF 2-2015-W. Be advised that all material you submit in response to this enforcement
action is subject to being made publicly available. If you believe that any portion of your
responsive material qualifies for confidential treatment under 5 U.S.C. 552(b), along with the
complete original document you must provide a second copy of the document with the
portions you believe qualify for confidential treatment redacted and an explanation of why
you believe the redacted information qualifies for confidential treatment under 5 U.S.C.
552(b).
Sincerely,
Wayne T. Lemoi
Director, Office of Pipeline Safety
PHMSA Southern Region
3

## Provenance

- Official: Yes
- Source: <https://primis.phmsa.dot.gov/enforcement-data/case/220150002W>
- Source ID: `phmsa-enforcement`
- SHA-256: `159e3650b9520c4e8a2ea22cb6ffed4cbad998e0a839e350df6aa37ab2bd5b02`
- Retrieved: 2026-08-20T04:44:44.458Z
- Exported: 2026-08-22T18:26:05.055Z
- Document slug: `phmsa-enforcement-220150002w`

### Source metadata

```json
{
  "cpf": "220150002W",
  "operator": "ROYAL ARMS GARDEN APARTMENTS",
  "region": "Southern",
  "pipelineType": "GAS INTRASTATE ONSHORE",
  "caseStatus": "CLOSED",
  "citedSections": [
    "192.1015(a)",
    "192.455(a)",
    "192.481",
    "192.625(f)",
    "192.721(a)",
    "192.747(a)"
  ],
  "dataAsOf": "08/04/2026 12PM",
  "caseDataAsOf": "2026-08-04",
  "attachmentCount": 2,
  "attachments": [
    {
      "name": "220150002W_warning letter_02192015.pdf",
      "url": "https://primis.phmsa.dot.gov/enforcement-documents/220150002W/220150002W_warning%20letter_02192015.pdf",
      "bytes": 294875,
      "category": "agency_document"
    },
    {
      "name": "220150002W_warning letter_02192015_text.pdf",
      "url": "https://primis.phmsa.dot.gov/enforcement-documents/220150002W/220150002W_warning%20letter_02192015_text.pdf",
      "bytes": 12522,
      "category": "agency_document"
    }
  ],
  "extractedAgencyDocumentCount": 1,
  "attachmentPolicy": "Official attachment links are retained. Agency-issued documents may also include a verified local PDF and page-level text representation.",
  "jurisdiction": "US",
  "operatorName": "ROYAL ARMS GARDEN APARTMENTS"
}
```