# AMERIGAS PROPANE LP — Warning Letter

**Citation:** CPF 220190003W  
**Type / status:** enforcement / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective:** Not stated  
**Published:** 2019-04-25

CLOSED warning letter citing 191.11(a), 191.11(b), 192.1007(e)(1)(v), 192.1011, 192.11(b).

## Document text

Warning Letter involving AMERIGAS PROPANE LP. PHMSA's enforcement data identifies the cited regulations as 191.11(a),  191.11(b),  192.1007(e)(1)(v),  192.1011,  192.11(b). The case was opened on 2019-04-25 and is reported as closed as of 2019-04-25. Open the official case record for notices, responses, orders, and the latest status.

Official case documents:

220190003W_Warning Letter_04252019.pdf: https://primis.phmsa.dot.gov/enforcement-documents/220190003W/220190003W_Warning%20Letter_04252019.pdf

220190003W_Warning Letter_04252019_text.pdf: https://primis.phmsa.dot.gov/enforcement-documents/220190003W/220190003W_Warning%20Letter_04252019_text.pdf

220190003W_Warning Letter_04252019_text.pdf

WARNING LETTER
CERTIFIED MAIL - RETURN RECEIPT REQUESTED
April 25, 2019
Mr. Hugh Gallagher
President and CEO
AmeriGas Propane, LP
460 N. Gulph Road
King of Prussia, PA 19406
CPF 2- 2019-0003W
Dear Mr. Gallagher:
On July 12, 2018, a representative of the Pipeline and Hazardous Materials Safety
Administration (PHMSA), Southern Region, Office of Pipeline Safety(OPS), inspected
AmeriGas Propane, LP (AmeriGas) liquefied petroleum gas (LP-Gas) records and selected
procedures in its Fort Myers, Florida, office and pipeline facilities in Lee County, Florida,
pursuant to Chapter 601 of 49 United States Code (U.S.C.). The AmeriGas Fort Myers
location operates under the Balgas business name.
As a result of the inspection, it is alleged that AmeriGas has committed probable violations
of the Pipeline Safety Regulations, Title 49, Code of Federal Regulations (CFR). The items
inspected and the probable violations are:
1. § 191.11 Distribution system: Annual report.
(a) General. Except as provided in paragraph (b) of this section, each operator
of a distribution pipeline system must submit an annual report for that system on
DOT Form PHMSA F 7100.1-1. This report must be submitted each year, not later
than March 15, for the preceding calendar year.
(b) Not required. The annual report requirement in this section does not apply
to a master meter system or to a petroleum gas system that serves fewer than 100
customers from a single source.
AmeriGas failed to meet the regulation because it did not submit complete and accurate
annual reports for all of its distribution pipeline systems. Specifically, AmeriGas failed
1



to provide a complete and accurate accounting of leaks repaired during calendar year
2017, on Part C of the ‘Annual Report for Calendar Year 2017,’on its petroleum gas
systems in Florida.
The Form PHMSA F 7100.1-1 is used to report all distribution pipeline systems, that
serve 100 or more customers, for a given commodity and within a given state. Through
its district offices, AmeriGas operates a number of petroleum gas distribution systems
serving 100 or more customers in the State of Florida. The data on these is collected at
the district level for inclusion in AmeriGas’ statewide Annual Reports.
The calendar year 2017 district-level Form PHMSA F 7100.1-1 for the Heron’s Glen
system did not identify any repaired leaks. This conflicted with leak repair records
maintained by the district. These records indicated at least 2 leaks repaired in 2017- one
on Embarcadero Way North on (or about) July 25, and one on Valparaiso Boulevard
North on (or about) August 3. These two leaks were not included on the district-level
Form PHMSA F 7100.1-1 and therefore not included in the ‘Annual Report for Calendar
Year 2017’ for AmeriGas petroleum gas systems in Florida.
2. § 192.11 Petroleum gas systems.
(a) . . . .
(b) Each pipeline system subject to this part that transports only petroleum gas
or petroleum gas/air mixtures must meet the requirements of this part and of
ANSI/NFPA 58 and 59.
AmeriGas failed to meet the requirements of NFPA-58 (2004)1 for each pipeline system
that transports petroleum gas, as follows:
NFPA 58 § 5.10.5 Where fusible elements are used, they shall have a melting point
not exceeding 250°F (121°C).
AmeriGas failed to meet the requirements of NFPA 58 § 5.10.5 which requires fusible
elements to have a melting point not exceeding 250°F.
The PHMSA inspector identified plastic air-line tubing2 at the Heron’s Glen regulator
station, used a fusible element, that was not marked with a melting point temperature.
The inspector asked AmeriGas personnel to provide the material specifications for the
tubing to demonstrate that it met the NFPA melting point requirement. AmeriGas
personnel researched the material specifications and determined that the melting point of
the installed plastic tubing exceeded 250°F and, subsequently, replaced the tubing with
tubing met the NFPA melting point requirement.
3. § 192.1011 What records must an operator keep?
An operator must maintain records demonstrating compliance with the
1 The 2004 edition of NFPA 58, “Liquefied Petroleum Gas Code (LP-Gas Code),” is the edition currently
incorporated, by reference, in §192.7.
2 The air-line tubing used in this instance was intended to meet the requirement that emergency shutoff valves
be provided with a means of closing by manual shutoff from a remote location and automatic shutoff
through thermal (fire) actuation.
2



requirements of this subpart for at least 10 years. The records must include copies
of superseded integrity management plans developed under this subpart.
§ 192.1007 What are the required elements of an integrity management plan?
A written integrity management plan must contain procedures for developing and
implementing the following elements:
(a) . . . .
(e) Measure performance, monitor results, and evaluate effectiveness.
(1) Develop and monitor performance measures from an established baseline to
evaluate the effectiveness of its IM program. An operator must consider the results
of its performance monitoring in periodically re-evaluating the threats and risks.
These performance measures must include the following:
(i) . . . .
(v) Number of hazardous leaks either eliminated or repaired as required by
§192.703(c) (or total number of leaks if all leaks are repaired when found),
categorized by material; and [...]
AmeriGas failed to maintain records demonstrating its compliance with certain
Subpart P, Gas Distribution Pipeline Integrity Management, requirements. Specifically,
AmeriGas failed to maintain records demonstrating that it considered in its performance
monitoring the performance measure required by § 192.1007 (e)(1)(v), that is the
number of hazardous leaks eliminated or repaired, as required by §192.703(c),
categorized by material.
When the PHMSA inspector requested the 2017 performance measures for the Heron’s
Glen system, AmeriGas personnel directed the inspector to the calendar year 2017
PHMSA F 7100.1-1 for the Heron’s Glen system for a summary of the performance
measures. While the PHMSA F 7100.1-1 provided operators a place to report
performance measures required by § 192.1007 (e)(1)(i) to (iv), it did not require or
provide a place for operators to report the performance measure required by § 192.1007
(e)(1)(v). AmeriGas did not provide any other records to demonstrate that it had
considered the number of hazardous leaks eliminated or repaired, categorized by
material, in its performance monitoring .
Under 49 U.S.C. § 60122 and 49 CFR § 190.223, AmeriGas is subject to a civil penalty not to
exceed $209,002 per violation per day the violation persists, up to a maximum of $2,090,022
for a related series of violations. For violations occurring prior to November 2, 2015, the
maximum penalty may not exceed $200,000 per violation per day, with a maximum penalty
not to exceed $2,000,000 for a related series of violations. We have reviewed the
circumstances and supporting documents involved in this case, and have decided not to
conduct additional enforcement action or penalty assessment proceedings at this time. We
advise you to correct the items identified in this letter. Failure to do so will result in AmeriGas
being subject to additional enforcement action.
No reply to this letter is required. If you choose to reply, in your correspondence please refer
to CPF 2-2019-0003W. Be advised that all material you submit in response to this
enforcement action is subject to being made publicly available. If you believe that any
3



portion of your responsive material qualifies for confidential treatment under 5 U.S.C.
552(b), along with the complete original document you must provide a second copy of the
document with the portions you believe qualify for confidential treatment redacted and an
explanation of why you believe the redacted information qualifies for confidential treatment
under 5 U.S.C. 552(b).
Sincerely,
James A. Urisko
Director, Office of Pipeline Safety
PHMSA Southern Region
4

## Provenance

- Official: Yes
- Source: <https://primis.phmsa.dot.gov/enforcement-data/case/220190003W>
- Source ID: `phmsa-enforcement`
- SHA-256: `52ba71253c9fd778ca5577d28a38fafbb928e202a502ee660db2f2945f6f7df2`
- Retrieved: 2026-08-20T04:44:44.458Z
- Exported: 2026-08-22T04:24:11.710Z
- Document slug: `phmsa-enforcement-220190003w`

### Source metadata

```json
{
  "cpf": "220190003W",
  "operator": "AMERIGAS PROPANE LP",
  "region": "Southern",
  "pipelineType": "GAS INTRASTATE ONSHORE",
  "caseStatus": "CLOSED",
  "citedSections": [
    "191.11(a)",
    "191.11(b)",
    "192.1007(e)(1)(v)",
    "192.1011",
    "192.11(b)"
  ],
  "dataAsOf": "08/04/2026 12PM",
  "caseDataAsOf": "2026-08-04",
  "attachmentCount": 2,
  "attachments": [
    {
      "name": "220190003W_Warning Letter_04252019.pdf",
      "url": "https://primis.phmsa.dot.gov/enforcement-documents/220190003W/220190003W_Warning%20Letter_04252019.pdf",
      "bytes": 619918,
      "category": "agency_document"
    },
    {
      "name": "220190003W_Warning Letter_04252019_text.pdf",
      "url": "https://primis.phmsa.dot.gov/enforcement-documents/220190003W/220190003W_Warning%20Letter_04252019_text.pdf",
      "bytes": 118996,
      "category": "agency_document"
    }
  ],
  "extractedAgencyDocumentCount": 1,
  "attachmentPolicy": "Official attachment links are retained. Agency-issued documents may also include a verified local PDF and page-level text representation.",
  "jurisdiction": "US",
  "operatorName": "AMERIGAS PROPANE LP"
}
```