# NORTHERN NATURAL GAS CO — Warning Letter

**Citation:** CPF 320071009W  
**Type / status:** enforcement / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective:** Not stated  
**Published:** 2007-02-26

CLOSED warning letter citing 192.225(a), 192.491(c).

## Document text

Warning Letter involving NORTHERN NATURAL GAS CO. PHMSA's enforcement data identifies the cited regulations as 192.225(a),  192.491(c). The case was opened on 2007-02-26 and is reported as closed as of 2007-02-26. Open the official case record for notices, responses, orders, and the latest status.

Official case documents:

320071009W_operator response to warning letter_04062007.pdf: https://primis.phmsa.dot.gov/enforcement-documents/320071009W/320071009W_operator%20response%20to%20warning%20letter_04062007.pdf

320071009W_warning Letter_02262007.pdf: https://primis.phmsa.dot.gov/enforcement-documents/320071009W/320071009W_warning%20Letter_02262007.pdf

320071009W_warning Letter_02262007.pdf

f .':r : I ff07
A
\7
U.S. Deportment
of Tronsoorlotion
Pipellne qnct
Hozordous lrloleriolt Soloty
Adminlst?qfion
901 Locust Street, Suite 462
Kansas City, MO 64106-2641
WARNING LETTER
February 26,2007
Mr. Royce Ramsay
Vice Presiden! Operations
Norlhern Natural Gas Co., Inc.
IIllS. 103rdStreet
Omaha, NE 68124
cPF 3-2007-1009w
Dear Mr- Ramsay:
On August 15-17,2006, a rcpresentative of the Michigan Public Service Commission acting
as an Interstate Agent for the Pipeline and Hazardous Materials Safety Administration
(PHMSA) pursuant to Chapter 601 of 49 United States Codc inspected your facilities and
records in Negaunee, Michigan.
As a result of the inspection, it appears that you have committed probable violations of the
Pipeline Safety Regulafions, Title 49, Code of Federal Regulations. The items inspected and
the probablc violation(s) are:
l. $192.491 Corrosion control records.
(c) Each opcrator shall maintain a record ofeach tes! s'rvey, or inspection
required by this subpart in suflicient detail to demonstrate thc adequacy of
corrosion control mcasures or that a corrosivc condition does not exist. These
records must be retaincd for at lease 5 years, except that records related to $$
192-465(a) and (e) and r92.475(b) must be retained for as long as the pipetine remains in
service.



During the M-35 replacement project, the inside of the pipeline was observed for internal
corrosion, but an inspcction report was not completed. Your personnel indicated that the
inspection was done but not documented.
2. $192.225 Welding procedures.
(a) Welding nrust be performed by a qualified rvelder in accordance with welding
procedures qualificd under section 5 ofAPI ll04 (ibr, see $192.7) or section IX of
the ASIIIE Boiler and Pressure Vessel Code (' Welding and Brazing Qualificationst,
(ibr, see $192.7) to produce welds meeting the requirements of this subpart. The
quality of the test rvelds used to qualify wclding procedures shall tre determined by
destructive testing in accordance with the appricabre rvelding standard(s).
According to the API 1 104 Welder Qualification Test Report, one of the welders that
worked on the M-35 replacement project was not qualified correctly to ApI 1104
standards. The correct number of destructive tests wero not perform€d: onlv two root-
bend tests were used for branch-on-pipe multiple welding qualification. ThL welder was
listed as qualified for branch-on-pipe werding even though ApI 1 104 scction 6.3.1
requir-es four Nick-Break tests for multiple weldine qualification.
Under 49 United States Code, $ 60122, you are subject to a civil penalty not to exceed $ t 00,000 .
for each violation for each day the violaiions persists up to a *u*irn,r* of $ 1,000,000 for any
related series of l'iolations. Wc have reviewed the circumstances ancl supporting documents
involved in this case, and have decided not to conduct additional enforcernent action or penalty
assessment proceedings at this time. We advise you to correct the item(s) identified in this letter.
Bc advised that failure to do so will result in Northem Natural Gas co. being subject to
additional enforcemcnt action.



No reply to this letter is required. If you choose to reply, in your correspondence please refer to
CPF 3-2007-1009W. Be advised that all material you submit in response to this enforcement
actionissubjecttobeingmadepubliclyavailable. Ifyoubelievethatanyportionofyour
responsive material qualifies for confidential treatment under 5 U.S.C. 5520); along with the
complete original docunent you must provide a second copy of the document with the poftions
you believe qualif,, for confidential treatment redactcd and an explanation ofwhy you believe
the redacted information qualifies for confidential keatment under 5 U.S.C. 552(b).
Sincerely,
Director, Central Region
Pipelinc and Hazardous Materials Safety Administration

## Provenance

- Official: Yes
- Source: <https://primis.phmsa.dot.gov/enforcement-data/case/320071009W>
- Source ID: `phmsa-enforcement`
- SHA-256: `fbd127d1413d3d232fa1377e4c535f175738eff608b3dc5bf974238aeb0a8f73`
- Retrieved: 2026-08-20T04:44:44.458Z
- Exported: 2026-08-22T19:56:56.700Z
- Document slug: `phmsa-enforcement-320071009w`

### Source metadata

```json
{
  "cpf": "320071009W",
  "operator": "NORTHERN NATURAL GAS CO",
  "region": "Central",
  "pipelineType": "GAS INTERSTATE ONSHORE",
  "caseStatus": "CLOSED",
  "citedSections": [
    "192.225(a)",
    "192.491(c)"
  ],
  "dataAsOf": "08/04/2026 12PM",
  "caseDataAsOf": "2026-08-04",
  "attachmentCount": 2,
  "attachments": [
    {
      "name": "320071009W_operator response to warning letter_04062007.pdf",
      "url": "https://primis.phmsa.dot.gov/enforcement-documents/320071009W/320071009W_operator%20response%20to%20warning%20letter_04062007.pdf",
      "bytes": 227908,
      "category": "party_submission"
    },
    {
      "name": "320071009W_warning Letter_02262007.pdf",
      "url": "https://primis.phmsa.dot.gov/enforcement-documents/320071009W/320071009W_warning%20Letter_02262007.pdf",
      "bytes": 93604,
      "category": "agency_document"
    }
  ],
  "extractedAgencyDocumentCount": 1,
  "attachmentPolicy": "Official attachment links are retained. Agency-issued documents may also include a verified local PDF and page-level text representation.",
  "jurisdiction": "US",
  "operatorName": "NORTHERN NATURAL GAS CO"
}
```