# CYPRESS INTERSTATE PIPELINE LLC — Warning Letter

**Citation:** CPF 320075006W  
**Type / status:** enforcement / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective:** Not stated  
**Published:** 2007-03-06

CLOSED warning letter citing 195.404(b)(1), 195.420(b).

## Document text

Warning Letter involving CYPRESS INTERSTATE PIPELINE LLC. PHMSA's enforcement data identifies the cited regulations as 195.404(b)(1),  195.420(b). The case was opened on 2007-03-06 and is reported as closed as of 2007-03-06. Open the official case record for notices, responses, orders, and the latest status.

Official case documents:

320075006W_Operator Response to warning letter_04122007.pdf: https://primis.phmsa.dot.gov/enforcement-documents/320075006W/320075006W_Operator%20Response%20to%20warning%20letter_04122007.pdf

320075006W_Warning Letter_03062007.pdf: https://primis.phmsa.dot.gov/enforcement-documents/320075006W/320075006W_Warning%20Letter_03062007.pdf

320075006W_Warning Letter_03062007.pdf

MAR O 7 2T|I
@
U.S. Deponmenl
of Tronsporlotion
Plpellne ond
Hozordous lloferlols sqtety
Admlnlrtrollon
901 Locust Steet, Suite 462
Kansas City, MO 6410S2641
WARNINGLETTER
CERTIX'IED MAIL - RETURN RECEIPT REOUESTED
March 6.2007
Mr. Ron McClain
Vice President Operations
Kinder Morgan Energy Partners, L.P.
500 Dallas Street, Suite 1000
Houston, TX77002
cPF 3-2007-5006W
DearMr. McClain:
On April 4-8, April I l-15, April 25-29, and May 9-13, 2005, a representative of the Pipeline
and Hazardous Materials Safety Administration (PHMSA) pursuant to Chapter 601 of 49
United States Code inspected your pipeline facilities in Illinois, Iowa, Kansas, Missouri,
Indiana, and Nebraska.
As a result of the inspection, it appears that you have committed probable violations of the
Pipeline Safety Regulations, Title 49, Code of Federal Regulations. The items inspected and
the probable violations are:
1. S195.404 Maps and Records.
(b) Each operator shall maintain for at least 3 years daily operating records that
indicate-
(f) The discharge pressure at each pump station;
Kinder Morgan did not have discharge pr€ssure records for Eldridge Pump Station for the
complete 24 hour period on October 31,2003. Also, there were no discharge pressure
records for Walnut Pump Station on October 27,2003.



2. $195.420 Valve maintenance.
(b) Each operator shall, at intervals not exceeding 7 1/2 months, but at least twice
each calendar year, inspect each mainline valve to deterrnine that it is
functioning properly.
On the KSM 103 Line within Bushton Pump Station, the KSM l0l/103 bypass valve, SIN
M335790-9, was installed in July 2004. This valve is operated weekly dwing normal
operations, but the valve did not receive Ihe2"" 2004 mainline valve inspection, and was
not inspected in 2005.
Under49UnitedStatesCode, S60l22,youaresubjecttoacivilpenaltynottoexceed$100,000
for each violation for each day the violations persists up to a maximum of $1,000,000 for any
related series of violations. We have reviewed the circumstances and supporting documents
involved in this case, and have decided not to conduct additional enforcement action or penalty
assessment proceedings at this time. We advise you to correct the items identified in this letter.
Failure to do so will result in Kinder Morgan Energy Partners, L.P. being subject to additional
enforcement action.
No reply to this letter is required. If you choose to reply, in your correspondence please refer to
CPF 3-2007-5006W. Be advised that all material you submit in response to this enforcement
action is subject to being made publicly available. Ifyou believe that any portion ofyour
responsive material qualifies for confidential treatment under 5 U.S.C. 552(b), along with the
complete original document you must provide a second copy of the document with the portions
you believe qualifu for confidential treatment redacted and an explanation of why you believe the
redacted information qualifies for confidential treatment under 5 U.S.C. 552@).
Director, Central Region
Pipeline and Hazardous Materials Safety Administration

## Provenance

- Official: Yes
- Source: <https://primis.phmsa.dot.gov/enforcement-data/case/320075006W>
- Source ID: `phmsa-enforcement`
- SHA-256: `140047ae844917153f19f8ad44f691ee420d060280631292ce7baeb87e0faabc`
- Retrieved: 2026-08-20T04:44:44.458Z
- Exported: 2026-08-22T22:35:51.725Z
- Document slug: `phmsa-enforcement-320075006w`

### Source metadata

```json
{
  "cpf": "320075006W",
  "operator": "CYPRESS INTERSTATE PIPELINE LLC",
  "region": "Central",
  "pipelineType": "INTERSTATE LIQUID ONSHORE",
  "caseStatus": "CLOSED",
  "citedSections": [
    "195.404(b)(1)",
    "195.420(b)"
  ],
  "dataAsOf": "08/04/2026 12PM",
  "caseDataAsOf": "2026-08-04",
  "attachmentCount": 2,
  "attachments": [
    {
      "name": "320075006W_Operator Response to warning letter_04122007.pdf",
      "url": "https://primis.phmsa.dot.gov/enforcement-documents/320075006W/320075006W_Operator%20Response%20to%20warning%20letter_04122007.pdf",
      "bytes": 86463,
      "category": "party_submission"
    },
    {
      "name": "320075006W_Warning Letter_03062007.pdf",
      "url": "https://primis.phmsa.dot.gov/enforcement-documents/320075006W/320075006W_Warning%20Letter_03062007.pdf",
      "bytes": 134098,
      "category": "agency_document"
    }
  ],
  "extractedAgencyDocumentCount": 1,
  "attachmentPolicy": "Official attachment links are retained. Agency-issued documents may also include a verified local PDF and page-level text representation.",
  "jurisdiction": "US",
  "operatorName": "CYPRESS INTERSTATE PIPELINE LLC"
}
```