# SOUTHERN STAR CENTRAL GAS PIPELINE, INC — Warning Letter

**Citation:** CPF 320181003W  
**Type / status:** enforcement / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective:** Not stated  
**Published:** 2018-10-05

CLOSED warning letter citing 192.619(a).

## Document text

Warning Letter involving SOUTHERN STAR CENTRAL GAS PIPELINE, INC. PHMSA's enforcement data identifies the cited regulation as 192.619(a). The case was opened on 2018-10-05 and is reported as closed as of 2018-10-05. Open the official case record for notices, responses, orders, and the latest status.

Official case documents:

320181003W_Operator Response to Notice_10302018.pdf: https://primis.phmsa.dot.gov/enforcement-documents/320181003W/320181003W_Operator%20Response%20to%20Notice_10302018.pdf

320181003W_Warning Letter_10052018.pdf: https://primis.phmsa.dot.gov/enforcement-documents/320181003W/320181003W_Warning%20Letter_10052018.pdf

320181003W_Warning Letter_10052018_text.pdf: https://primis.phmsa.dot.gov/enforcement-documents/320181003W/320181003W_Warning%20Letter_10052018_text.pdf

320181003W_Warning Letter_10052018_text.pdf

WARNING LETTER
CERTIFIED MAIL - RETURN RECEIPT REQUESTED
October 5, 2018
Mr. Shawn Patterson
Chief Operations Officer
Southern Star Central Gas Pipeline, Inc.
4700 State Route 56
Owensboro, KY 42301
CPF 3-2018-1003W
Dear Mr. Patterson:
On August 31, 2017, a representative of the Pipeline and Hazardous Materials Safety
Administration (PHMSA), pursuant to Chapter 601 of 49 United States Code (U.S.C.),
received a Safety Related Conidtion Report (SRCR) regarding Southern Star Central Gas
Pipeline, Inc. facilities (SSCGP) in Overland Park, KS.
As a result of the inspection, it is alleged that you have committed a probable violation of the
Pipeline Safety Regulations, Title 49, Code of Federal Regulations (CFR). The item inspected
and the probable violation is:
1. §192.619 Maximum allowable operation pressure: Steel or plastic pipelines.
(a) No person may operate a segment of steel or plastic pipeline at a pressure that
exceeds a maximum allowable operating pressure determined under paragraph (c)
or (d) of this section, or the lowest of the following . . .
SSCGP failed to operate a segment of steel pipeline at a pressure under the Maximum
Allowable Operating Pressure (MAOP). SSCGP in a SRCR on August 31, 2017, informed
PHMSA that on August 29, 2017, the Pressure Regulating Station in Overland Park, Kansas
achieved a pressure of 321 psi. The MAOP of this pipeline is 260 psi; therefore, a pressure of
123% of MAOP was reached. Both the regulating and overpressure protection devices failed
at the location causing 67 feet of the pipeline to exceed the MAOP for a total of 41 minutes.



Operation on this specific line was by-passed. SSCGP’s operating regulater was removed,
inspected, repaired, cleaned, and returned to service. The overpressure protection device was
replaced.
Under 49 U.S.C. § 60122 and 49 CFR § 190.223, you are subject to a civil penalty not to
exceed $209,002 per violation per day the violation persists, up to a maximum of $2,090,022
for a related series of violations. For violations occurring prior to November 2, 2015, the
maximum penalty may not exceed $200,000 per violation per day, with a maximum penalty
not to exceed $2,000,000 for a related series of violations. We have reviewed the
circumstances and supporting documents involved in this case, and have decided not to
conduct additional enforcement action or penalty assessment proceedings at this time. We
advise you to correct the item identified in this letter. Failure to do so will result in Souther
Star Central Gas Pipeline being subject to additional enforcement action.
No reply to this letter is required. If you choose to reply, in your correspondence please refer
to CPF 3-2018-1003W. Be advised that all material you submit in response to this
enforcement action is subject to being made publicly available. If you believe that any portion
of your responsive material qualifies for confidential treatment under 5 U.S.C. 552(b), along
with the complete original document you must provide a second copy of the document with
the portions you believe qualify for confidential treatment redacted and an explanation of why
you believe the redacted information qualifies for confidential treatment under 5 U.S.C.
552(b).
Sincerely,
Allan C. Beshore
Director, Central Region, OPS
Pipeline and Hazardous Materials Safety Administration
2

## Provenance

- Official: Yes
- Source: <https://primis.phmsa.dot.gov/enforcement-data/case/320181003W>
- Source ID: `phmsa-enforcement`
- SHA-256: `da68227521239bc942ece83ee9110c96d3b63a107d3d12f17262e9feef5e59e3`
- Retrieved: 2026-08-20T04:44:44.458Z
- Exported: 2026-08-22T04:07:08.907Z
- Document slug: `phmsa-enforcement-320181003w`

### Source metadata

```json
{
  "cpf": "320181003W",
  "operator": "SOUTHERN STAR CENTRAL GAS PIPELINE, INC",
  "region": "Central",
  "pipelineType": "GAS INTERSTATE ONSHORE",
  "caseStatus": "CLOSED",
  "citedSections": [
    "192.619(a)"
  ],
  "dataAsOf": "08/04/2026 12PM",
  "caseDataAsOf": "2026-08-04",
  "attachmentCount": 3,
  "attachments": [
    {
      "name": "320181003W_Operator Response to Notice_10302018.pdf",
      "url": "https://primis.phmsa.dot.gov/enforcement-documents/320181003W/320181003W_Operator%20Response%20to%20Notice_10302018.pdf",
      "bytes": 84489,
      "category": "party_submission"
    },
    {
      "name": "320181003W_Warning Letter_10052018.pdf",
      "url": "https://primis.phmsa.dot.gov/enforcement-documents/320181003W/320181003W_Warning%20Letter_10052018.pdf",
      "bytes": 794014,
      "category": "agency_document"
    },
    {
      "name": "320181003W_Warning Letter_10052018_text.pdf",
      "url": "https://primis.phmsa.dot.gov/enforcement-documents/320181003W/320181003W_Warning%20Letter_10052018_text.pdf",
      "bytes": 284528,
      "category": "agency_document"
    }
  ],
  "extractedAgencyDocumentCount": 1,
  "attachmentPolicy": "Official attachment links are retained. Agency-issued documents may also include a verified local PDF and page-level text representation.",
  "jurisdiction": "US",
  "operatorName": "SOUTHERN STAR CENTRAL GAS PIPELINE, INC"
}
```