# LINK ENERGY PIPELINE LIMITED PARTNERSHIP — Notice of Probable Violation

**Citation:** CPF 420025011  
**Type / status:** enforcement / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective:** Not stated  
**Published:** 2002-07-31

CLOSED notice of probable violation citing 195.452(b)(4), 195.452(c), 195.452(c)(1)(i).

## Document text

Notice of Probable Violation involving LINK ENERGY PIPELINE LIMITED PARTNERSHIP. PHMSA's enforcement data identifies the cited regulations as 195.452(b)(4),  195.452(c),  195.452(c)(1)(i). The case was opened on 2002-07-31 and is reported as closed as of 2006-08-18. Proposed civil penalty: $110,000. Assessed civil penalty: $90,000. Open the official case record for notices, responses, orders, and the latest status.

Official case documents:

420025011_Final Order_06232004.pdf: https://primis.phmsa.dot.gov/enforcement-documents/420025011/420025011_Final%20Order_06232004.pdf

420025011_Final Order_06232004.pdf

o
USDeportrnent of Tronsportolion
Re3eorEh ond
sPccaol P"ogroms
AdmihistrEfion
{00 Sevenlh Sl . S W
Washrngton. D.C 20590
JUN 2 3 2004
Mr. Louis Soldano
Vice President and Assistant General Counsel
Enron Pipeline Services Company
P.O. Box 1188
Houston, TX 77251-1 188
Re; CPF No. 4-2002-5011
Dear Mr. Soldano:
Enclosed is the Final Order issued by the Associate Administrator for Pipeline Safety in the
above-referenced case. It makes findings of violation and assesses a civil penalty of $90,000.
Because Enron Pipeline Services Company (EPSC) filed for Chapter 11 bankruptcy on June 16,
2003, the civil penalty will be collected through the bankruptcy proceeding. Based on information
you provided that EPSC is no longer continuing in the business ofoperating pipelines and has no
intention of conducting such business in the future, the Final Order also withdraws the Proposed
Compliance Order as moot. Your receipt of the Final Order constitutes service of that document
under 49 C.F.R. 6 190.5.
Sincerely,
$*
James ReYnolds
PiPeline ComPliance RegistrY
Office of PiPeline SafetY
Enclosure
CERTIFIED MAIL. RETURN RECEIPT REqUESTED



DEPARTMENT OF TRANSPORTATION
RESEARCH AND SPECIAL PROGRAMS ADMIMSTRATION
OFFICE OF PIPELINE SAFETY
WASHINGTON. DC 20590
In the Matter of
Enron Pipeline Services Company,
Respondent.
CPF No. 4-2002-5011
FINAL ORDER
On April 3,2002, pursuant to 49 U.S.C, $ 60117, a representative of the Office of Pipeline Safety
(OPS) inspected Enron Pipeline Services Company's @espondent's) integritymanagement program
at Respondent's facility in Houston, Texas. As a result of the inspection, the Director, Southwest
Region, OPS, issued to Respondent, by letter dated July 31,200?, a Notice of Probable Violation,
Proposed Civil Penalty, and Proposed Compliance Order (Notice). [n accordance with 49 C.F.R.
$ 190.207, the Notice proposed finding that Respondent had committed multiple violations of
49 C.F.R. S 195.452 and proposed assessing civil penalties totaling $110,000 for the alleged
violations. The Notice also proposed that Respondent take certain measures to correct the alleged
violations.
After requesting and receiving an extension oftime to respond, Respondent responded to the Notice
by letter dated October 9,2002 (Response). Respondent presented information and arguments
contesting the alleged violations, contested any assessment of civil penalties in this enforcement
action on procedural grounds, and requested a hearing. By letter dated February 12,2004,
Respondent withdrew its request for a hearing.
FINDINGS OF VIOLATION
Item I in the Notice alleged that Respondent violated 49 C.F.R. $ 195.452(c) by failing to include
a schedule prioritizing the baseline assessm€nts of its pipeline segments that could affect a high
,onr"qu*.i area ("HCA segments') by certain risk factors as an element of its baseline assessment
plan. itre integrity management regulations require pipeline operators to establish a schedule for
their baseline assessments that prioritizes HCA segments according to specified factors that reflect
the risk conditions on each segment, These risk factors are listed in $ 195.a52(e)' Operators of
Category 1 pipelines are requirid to assess at least 50 percent of the HCA segments, beginning with
the hlghest risk pipe, not later than September 30, 2004 and must complete all baseline assessments
by March 31, 2008.



z
Il its response' Respondent presented a one-page flow chart and an short excerpt fiom its baseline
assessment plan indicating that it had planned to conduct all of its baseline assessments ..in the next
five years" and that the results ofits existing risk analysis process were to be used in setting priorities
for the baseline assessment schedule. Under the ,"I"u*t provision, however, the baseline
assessment schedule itself had to be in place as an element of thebaseline assessment plan. On this
point, Respondent asserts that it "had available at that time a sogment listing in risk ranking order,"
and claims that it did not provide this list to the OPS inspectorbecause thisinformation "w:6 never
requested" by the inspector. As a required element of its baseline assessment plan, however,
Respondent had the burden of producing a completed baseline assessment schedule reflecting the
manner in which the risk factors listed in section 195.452(e) were weighed. If its basJline
assessment schedule was not included in Respondent's plan, Respondent bears the responsibility for
the omission. Moteover, in its response to the Notice issued in this enforcement action, Respondent
still has not demonstrated that it had a baseline assessment schedule in place at the time of the
inspection. For example, in its response, Respondent did not identify its highest and lowest risk
HCA segments or give the dates that were scheduled for the first and last baseline assessments on
these segments, much less provide a copy of the schedule in its entirety. Accordingly, I find that
Respondent violated 49 C.F.R. $ 195.452(c) by failing to include a schedule prioririzingthe baseline
assessments of its HCA segments by the specified risk factors as an element of its baseline
assessment plan.
Item 2 in the Notice alleged that Respondent committed multiple violations of 49 C.F.R.
$ 195.452(bX4) by failing to adequately address six of the elements required in to be included in its
written integrity management program including: (1) a process for integrated information analysis;
(2) a process for continual integrity assessments at intervals not to exceed five years; (3) a process
for identification of preventative and mitigative measures to protect each HCA; (4) methods to
measure the program's effectiveness; (5) a process for review of the results of certain program
activities by a qualified individual; and (6) a proc€ss for making decisions regarding implementation
of each program requirement (Elements 1-6).
In its response, Respondent contended that each of these required elements were adequately
addressed in its program. With respect to Element 1, a process for integrated information analysis,
operators are required to have a comprehensive plan for systematically collecting and effectively
utilizing all data on a system-wide basis, particularly the data sets necessary to evaluate areas of
known concern. Existing management information system (MIS) databases are one source of data,
as are external sources such as industry-wide and agency reports and databases that include
information such as soil data, demographics, and hydrology, as examples. An effective data
integration plan would explain, among other things, how data elements are structured and the manner
in which consistency in units is achieved or graphical overlays are utilized. In this case, Respondent
provided only a general statement about an existing database of information about its pipelines, and
noted that it used algorithms to model the relative risks based on the inputs from this information
database. Respondent, howover, failed to demonstrate that its written integrity management program
described its information analysis process in sufficient detail that would have permitted the OPS
inspector to evaluate the capacity ofthis process to produce the intended results.



J
With respect to Element 2, a process for continual integnty assessments, after completing the
baseline assessment, an operator must periodically assess the integrity of its HCA segments as
frequently as needed to assure pipeline integrity. An operator must base the frequency of the
periodic assessments on risk factors specific to its line pipe except that the interval may not exceed
five years. kr this case, Respondent provided a general statement about including relevant
information when evaluating risks and identified four personnel groupings who would be available
to provide input and guidance in the application of its program. Respondent, however, failed to
demonstrate that its written program described its periodic integrity assessment process in sufficient
detail that would have permitted the OPS inspector to evaluate the appropriateness of the chosen
interval or the validity ofits engineering basis.
With respect to Element 3, a process for identification of additional preventative and mitigative
measures to protect each HCA, Respondent stated that a number of mitigative measures already
formed part ofits ongoing operational activities and pointed out that it did include a list ofsuch
measures in its written program. Respondent, however, failed to recognize that this is a process-
oriented requirement and as such it requires pipeline operators to go beyond merely identifying
known mitigative measures and listing equipment. In order to comply with this requirement,
operators must establish criteria that, when encountered, will trigger implementation of the
additionalpreventativeandmitigativemeasrrgs(l.e.,installationoftheequipment). Initsresponse,
Respondent acknowledged that its written program failed to identify the circumstances and criteria
by which determinations that additional mitigative measures were needed would be made.
With respect to Element 4, methods to measure the program's effectiveness, Respondent points out
that it did include a list of metrics that it intended to track in order to judge the effectiveness of its
program. Although we believe operators would be well-served by enhancing the implementation
aspects of this elernent of their programs well beyond Respondent's effort, I find that Respondent
has met the minimum threshold of this aspect of the implementation requirements at this stage of
the development of its program. Accordingly, the relevant fraction of the civil penalty amourt
proposed for this element will be withdrawn.
With respect to Element 5, a process for review of the results of program activities by a qualified
individual, Respondent stated that as it interprets this provision, the normal process of conducting
physical assessments performed by trained personnel would satisfy this requirement. Respondent's
int,erpretation, however, is incorrect. In order forpipeline integritymanagement programs to be fully
effective, a high-level quality review process is essential. A qualifred individual who may not have
been directly involved in conducting the field assessments provides a means of reviewing the tool
run logs and other relevant data and ensuring that integrity threat de terminations and other j udgments
have been appropriately made. An adequate quality review process involves at a minimum the
identification ofthe title ofthe person designated as the qualified individual, a description ofthe
qualifications needed to perform this function, and a detailed description of the manner in which
information and decisions are to be reviewed and the results of the quality review are to be
documented and records kept. In its response, Respondent acknowledged that its program had no
such descriptive process for this required element'



4
With respect to Element 6, a process for making decisions regarding implementation of each
program element, Respondent noted that decision making is inherent to the process ofprogram
implementation itself and as a result, citing this provision is redundant in light of the process-
oriented violations already covered. While we believe that establishing and following sound
processes is important to consistency in achieving the best outcomes, I do not find it appropriate in
this case to cite $ 195.452OX4)(ii) as an additional violation in light of the violations already
covered in Item 2. Accordingly, the relevant fraction of the civil penalty amount proposed for this
element will be withdrawn.
Accordingly, I find that Respondent violated 49 C.F.R. $ 195.452(b)(4) by failing to adequately
address the following four elements required in to be included in its written integrity management
program: aprocess for integrated information analysis; aprocess for continual integrity assessments
at intervals not to exceed five years; a process for identification of preventative and mitigative
measures to protect each HCA; and a process for review of the results of program activities by a
qualified individual.
Item 3 in the Notice alleged that Respondent violated 49 C.F,R. $ 195.452(c)(1)(i) by failing to
document the capability of its assessment methods to evaluate, among other things, seam integrity
on low frequency electric resistance welded (ERW) pipe or lap welded pipe susceptible to
longitudinal seam failures.
In its response, Respondent contends that none ofits pipe is susceptible to longitudinal seam failures
and that as a result, documenting the capability of its intemal inspection tools to assess seam
integrity was not required by the regulation. Respondents argument, however, is unpersuasive'
Respondent has acknowledged that largeportions ofits system are composed of ERW or lap welded
pipe manufactured prior to 1970. It is well established in the pipeline safety regulations that all pre-
1970 ERW pipe and lap welded pipe is deemed susceptible to longitudinal seam failures unless an
engineering analysis shows otherwise (See, e.g.,the pressure-testing requirements at 49 C.F.R.
$195.303(d). Initsresponse,RespondentreferencesanarticleintheAugust5,2002editionofthe
Oil and Gas Journal and asserts that it worked through a decision algorithm from the article and
concluded that an assessment ofseam integrity was not necessary on any ofthe pipelines it operated.
A comparison ofpipeline characteristics with an articlepublished in an industryperiodical, however,
does not constitute an engineering analysis for purposes ofovercoming the presumption that pre-
1970 ERW or lap weldeJpipe is susceptible to longitudinal seam failures. ln conducting such an
engineering analysis on *y giu"n portion of a pipeline, an operator must consider the seam-related
teat tristory ofthi pipe andpipe manufacturinginformation such as the mechanical properties of the
steel including fracture toughness; the manufacturing process and controls related to seam properties
including whether the ERW process was high-frequency or low-frequency, whether the weld seam
was heat treated, whether the seam was inspected, the test pressure and duration during mill
hydrotest; the quality control of the steel-making process; and other factors pertinent to seam
properties and quality. No such engineering analysis report was submitted to the OPS inspector or
in r"rponr. to tiis enforcernent actlon. Accordingly, I find that Respondent violated 49 C'F'R'
$ 195.452(cxl)(i) by failing to document the capability of its assessment methods to assess seam
integrity onii, ptu-ifZO niW pipe or lap welded pipe susceptible to longitudinal seam failures'



5
These findings of violation will be considered prior offenses in any subsequent enforcement action
taken against Respondent.
ASSESSMENT OF PENALTY
Under 49 U.S.C. § 60122, Respondent is subject to a civil penalty not to exceed $100,000 per
violation for each day of the violation up to a maximum of $1,000,000 for any related series of
violations.
In its response, Respondent contested any assessment of civil penalties in this enforcement action
on procedural grounds, contending that the Notice subjected Respondent to civil penalties in a
manner contrary to the requirements of 49 C.F.R. Part 190. Specifically, Respondent cited
49 C.F.R. § 190.223(d) which states that:
No person shall be subject to a civil penalty under this section for the violation of any
requirement of this subchapter and an order issued under § 190.217, § 190.219 or
§ 190.233 if both violations are based on the same act.
While it is true that the July 31, 2002 Notice issued to Respondent involves both a civil penalty and
a § 190.217 order, Respondent's contention that § 190.223(d) is applicable to this enforcement
proceeding is incorrect. Section 190.223(d) applies only when OPS has previously issued an order
under § 190.217, § 190.219 or § 190.233 that assessed monetary civil penalties, and the pipeline
operator subject to that existing order subsequently fails to comply with the terms of that order.
Therefore, § 190.223(d) is inapplicable in this instance because this enforcement action is not based
on a failure to comply with a previously existing order.
49 U.S.C. § 60122 and 49 C.F.R. § 190.225 require that, in determining the amount of the civil
penalty, I consider the following criteria: nature, circumstances, and gravity of the violation, degree
of Respondent's culpability, history of Respondent's prior offenses, Respondent's ability to pay the
penalty, good faith by Respondent in attempting to achieve compliance, the effect on Respondent's
ability to continue in business, and such other matters as justice may require.
With respect to Item 1, the Notice proposed a civil penalty of $25,000 for Respondent's failure to
include a schedule prioritizing the baseline assessments of its HCA segments by the specified risk
factors as an element of its baseline assessment plan. In the absence of a complete schedule, OPS
is unable to determine whether the actual result of a given operator's application of its risk ranking
process to its HCA segment list corresponds to the required risk factors or evaluate the feasibility
an operator's plan to complete the requisite number of HCA segment assessments within the relevant
time frame. Respondent has presented no information that would warrant mitigation of the proposed
penalty amount. Accordingly, having reviewed the record and considered the assessment criteria,
I assess Respondent a civil penalty of $25,000 for this Item.



6
With respect to Item 2, the Notice proposed a civil penalty of $60,000 for Respondent's failure to
adequately address six elements required to be included in its written integrity management program
(referenced above as Elements 1-6) including a process for integrated ihformation analysis; aprocess
for continual integrity assessments at intervals; a process for identification ofpreventative and
mitigativemeasures to protect eachHCA;methods to measwethe program's effectiveness; aprocess
for review of the results of certain progam activities by a qualified individual; and a process for
making decisions regarding implementation of each progam element. In the absence of detailed
descriptions of the processes for implementing these program elements, OPS is unable to determine
whether the relevant processes are likely to be employed in a successful manner and achieve a result
consistent with public safety. As noted above, Respondent did present information that wa:ranted
withdrawal of the penalty amounts proposed for the adequacy of Respondent's methods to measure
the program's effectiveness and Respondent's process for making decisions regarding
implementation of each program element. Therefore, I find that a proportional reduction in the civil
penalty amount for two of the six elements of this Item is warranted. Respondent has presented no
information that would warrant mitigation of the proposed penalty amount for the other four
elements. Accordingly, having reviewed the record and considered the assessment criteria, I assess
Respondent a civil penalty of $40,000 for this Item.
With respect to Item 3, the Notice proposed a civil penalty of $25,000 for Respondent's failure to
document the capability of its assessment methods to assess seam integrity on its pre-1970 ERW
pipe or lap welded pipe susceptible to longitudinal seam failures. In the absence of such
documentation, OPS is unable to determine whether the assessment methods selected by an operator
are suitable for the particular application. Respondent has presented no information that would
warrant mitigation of the proposed penalty amount. Accordingly, having reviewed the record and
considered the assessment criteria, I assess Respondent a civil penalty of $25,000 for this Item.
Accordingly, having reviewed the record and considered the assessment criteria, I assess Respondent
a total civil penalty ofg90,000. Because Respondent filed for Chapter I I banlruptcy on June 16,
2003, the civil penalty will be collected through the bankruptcy proceeding (In re Enron Pipeline
Services Company,CaseNo. 03-13918 AJG, jointlyadministeredwithft re Enron Corp., et al,Case
No. 01-16034 AJG, S.D. New York). A proof of claim has been filed with the banlffuptcy court
(Claim No. 0000024624).
COMPLIANCE ORDER
The Notice proposed a Compliance Order in connection with the above referenced violations.
Because Respondent has informed us that it is no longer continuing in the business of operating
pipelines und h* no intention of conducting such business in the future, the Proposed Compliance
Order is withdrawn as moot.
under 49 C.F.R. $ 190.215, Respondent has a right to petition for reconsjderation of this Final
Order. Should Respondent etect io do so, the petition must be received within 20 days of



I
Respondent's receipt of this Final Order and must contain a brief statement of the issue(s). In the
absence of a timely filed pefition, this Final Ord.er is the final administrative action in this
proceeding. The terms and conditions ofthis Final order are effective on receipt.
W,/1.r^f1G*:.
Stacey Gerard
Associate Administrator
for Pipeline Safety
iuN 2 3 2004
Date Issued

## Provenance

- Official: Yes
- Source: <https://primis.phmsa.dot.gov/enforcement-data/case/420025011>
- Source ID: `phmsa-enforcement`
- SHA-256: `6c2c244048539472e934410d7aadc76add715289bcc049dffe5e6dc9bf57788b`
- Retrieved: 2026-08-20T04:44:44.458Z
- Exported: 2026-08-22T21:16:55.868Z
- Document slug: `phmsa-enforcement-420025011`

### Source metadata

```json
{
  "cpf": "420025011",
  "operator": "LINK ENERGY PIPELINE LIMITED PARTNERSHIP",
  "region": "Southwest",
  "pipelineType": "INTERSTATE LIQUID ONSHORE",
  "caseStatus": "CLOSED",
  "citedSections": [
    "195.452(b)(4)",
    "195.452(c)",
    "195.452(c)(1)(i)"
  ],
  "dataAsOf": "08/04/2026 12PM",
  "caseDataAsOf": "2026-08-04",
  "attachmentCount": 1,
  "attachments": [
    {
      "name": "420025011_Final Order_06232004.pdf",
      "url": "https://primis.phmsa.dot.gov/enforcement-documents/420025011/420025011_Final%20Order_06232004.pdf",
      "bytes": 478756,
      "category": "agency_document"
    }
  ],
  "extractedAgencyDocumentCount": 1,
  "attachmentPolicy": "Official attachment links are retained. Agency-issued documents may also include a verified local PDF and page-level text representation.",
  "jurisdiction": "US",
  "operatorName": "LINK ENERGY PIPELINE LIMITED PARTNERSHIP"
}
```