# GAS TRANSMISSION NORTHWEST LLC — Warning Letter

**Citation:** CPF 520070015W  
**Type / status:** enforcement / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective:** Not stated  
**Published:** 2007-04-20

CLOSED warning letter citing 192.615(b)(1), 192.619(a)(3).

## Document text

Warning Letter involving GAS TRANSMISSION NORTHWEST LLC. PHMSA's enforcement data identifies the cited regulations as 192.615(b)(1),  192.619(a)(3). The case was opened on 2007-04-20 and is reported as closed as of 2007-04-20. Open the official case record for notices, responses, orders, and the latest status.

Official case documents:

520070015W_Warning Letter_04202007.pdf: https://primis.phmsa.dot.gov/enforcement-documents/520070015W/520070015W_Warning%20Letter_04202007.pdf

520070015w_warning letter_04202007_text.pdf: https://primis.phmsa.dot.gov/enforcement-documents/520070015W/520070015w_warning%20letter_04202007_text.pdf

520070015w_warning letter_04202007_text.pdf

o
U S. Department
of Transportation
Pipeline and
Hazardous Materials Safety
Administration
12300W Dakota Ave, SUtte tt0
Lakewood, CO 80228
WARNING LETTER
CERTIFIED MAIL - RETURN RECEIPT RE UESTED
April 20, 2007
Mr. Ross Parker
Regional Director
GTN and North Baja Systems
1400 SW 5'" Ave.
Suite 900
,
Portland, WA 97201
SENT TO COMPLIANCE REGISTRY
Hardcopy Electromcally
¹ of Copies&/ Date ~Ã
CPF No. 5-2007-0015W
Dear Mr. Parker:
Between November 13 and December 1, 2006, a representative of the Washington Utilities and
Transportation Commission (WUTC) acting as an agent for the Pipeline and Hazardous Materials
Safety Administration (PHMSA), pursuant to Section 60106(a) of Title 49, United States Code,
conducted an onsite pipeline safety inspection of your pipeline facilities in Washington State.
As a result of the inspection, it appears that you have committed probable violations, as noted below,
of the pipeline safety regulations Title 49, Code of Federal Regulations, Part 192. The probable
violations are:
$192. 619 Maximum allowable operating pressure: Steel or plastic pipelines.
(a) Except as provided in paragraph (c) of this section, no person may operate a segment
of steel or plastic pipeline at a pressure that exceeds the lowest of the following:
(3) The highest actual operating pressure to which the segment was subjected
during the 5 years preceding July 1, 1970 (or in the case of offshore gathering
lines, July 1, 1976), unless the segment was tested in accordance with paragraph
(a) (2) of this section after July 1, 1965 (or in the case of offshore gathering lines,
July 1, 1971), or the segment was uprated in accordance with Subpart K of this
part.
GTN's A-Line (36-inch) was installed and tested in 1960. GTN was unable to provide all
pressure records for the 5 year period immediately preceding July 1, 1970. Some partial
records were made available from GTN's Portland office. The pipeline segments in
Washington State may not have operated at the current MAOP during the 5 years preceding
July 1, 1970 and GTN may have a lower regulatory-based MAOP than they are currently
using.



2. $192. 615(b) Emergency plans.
(b) Each operator shall:
(1) Furnish its supervisors who are responsible for emergency action a copy of
that portion of the latest edition of the emergency procedures established
under paragraph (a) of this section as necessary for compliance with those
procedures.
There was no Emergency manual on-site in the Starbuck compressor station. Apparently the
operations supervisor keeps the E-plan in his vehicle which is not always present and on-site.
TransCanada procedure OMI V-2 states "each supervisor shall keep the emergency procedures
manual in each office in a clearly designated location. It could be argued that TransCanada does not
consider the Starbuck compressor station to be an office. The issue is that there are people working
there eriodically and the supervisor may or may not be present. Therefore, the manual would not
p
always be on-site in an emergency until the supervisor arrived.
Under 49 United States Code, g 60122, you are subject to a civil penalty not to exceed $100, 000 for
each violation for each day the violation persists up to a maximum of $1, 000, 000 for any related
series of violations. We have reviewed the circumstances and supporting documents involved in
this case, and have decided not to conduct additional enforcement action or penalty assessment
proceedings at this time. We advise you to correct the item(s) identified in this letter. Failure to do so
will result in GTN being subject to additional enforcement action.
No reply to this letter is required. If you choose to reply, in your correspondence please refer to CPF
5-2007-0015W. Be advised that all material you submit in response to this enforcement action is
subject to being made publicly available. If you believe that any portion of your responsive materia '
I
qualifies for confidential treatment under 5 U. S. C. 552(b), along with the complete original document
you must provide a second copy of the document with the portions you believe qualify for
confidential treatment redacted and an explanation of why you believe the redacted information
qualifies for confidential treatment under 5 U. S. C, 552(b).
Sincerely
s Hoidal c
Director, Western Region
Pipeline and Hazardous Materials Safety Administration
cc: Alan Rathbun, WUTC
David Lykken, WUTC
PHP-60 Compliance Registry
PHP-500 Tom Finch

## Provenance

- Official: Yes
- Source: <https://primis.phmsa.dot.gov/enforcement-data/case/520070015W>
- Source ID: `phmsa-enforcement`
- SHA-256: `146c92368d4f08e206ebb75928cc19c57c8098772ac5ac346457b7ddae1bb610`
- Retrieved: 2026-08-20T04:44:44.458Z
- Exported: 2026-08-22T20:32:18.177Z
- Document slug: `phmsa-enforcement-520070015w`

### Source metadata

```json
{
  "cpf": "520070015W",
  "operator": "GAS TRANSMISSION NORTHWEST LLC",
  "region": "Western",
  "pipelineType": "GAS INTRASTATE ONSHORE",
  "caseStatus": "CLOSED",
  "citedSections": [
    "192.615(b)(1)",
    "192.619(a)(3)"
  ],
  "dataAsOf": "08/04/2026 12PM",
  "caseDataAsOf": "2026-08-04",
  "attachmentCount": 2,
  "attachments": [
    {
      "name": "520070015W_Warning Letter_04202007.pdf",
      "url": "https://primis.phmsa.dot.gov/enforcement-documents/520070015W/520070015W_Warning%20Letter_04202007.pdf",
      "bytes": 29329,
      "category": "agency_document"
    },
    {
      "name": "520070015w_warning letter_04202007_text.pdf",
      "url": "https://primis.phmsa.dot.gov/enforcement-documents/520070015W/520070015w_warning%20letter_04202007_text.pdf",
      "bytes": 109446,
      "category": "agency_document"
    }
  ],
  "extractedAgencyDocumentCount": 1,
  "attachmentPolicy": "Official attachment links are retained. Agency-issued documents may also include a verified local PDF and page-level text representation.",
  "jurisdiction": "US",
  "operatorName": "GAS TRANSMISSION NORTHWEST LLC"
}
```