CLOSED warning letter citing 192.467(c), 192.479.

## Document text

Warning Letter involving NORTHWEST PIPELINE LLC. PHMSA's enforcement data identifies the cited regulations as 192.467(c),  192.479. The case was opened on 2007-07-09 and is reported as closed as of 2007-07-09. Open the official case record for notices, responses, orders, and the latest status.

Official case documents:

520071012W_warning letter_07092007.pdf: https://primis.phmsa.dot.gov/enforcement-documents/520071012W/520071012W_warning%20letter_07092007.pdf

520071012w_warning letter_07092007_text.pdf: https://primis.phmsa.dot.gov/enforcement-documents/520071012W/520071012w_warning%20letter_07092007_text.pdf

520071012w_warning letter_07092007_text.pdf

S NT TO COMPLIANCE REGIS'
E
Hardcopy Electrontca y 4j Oa
0 of Copies&i Date
O
U. S Department
of Transportation
Pipeline and
Hazardous Materials Safety
Administration
12300 W Dakota Ave, SuIte 110
Lakewood, CO 80228
WARNING LETTER
CERTIFIED MAIL - RETURN RECEIPT RE UESTKD
July 9, 2007
Mr. Randy Barnard
Vice President, Operations
Northwest Pipeline Corporation
2800 Post Oak Blvd.
,
Mail Stop 21
Houston, TX 77056
CPF 5-2007-1012W
Dear Mr. Barnard:
During the week of May 21-27, 2007, a representative of the Washington Utilities and
Transportation Commission (WUTC), pursuant to Chapter 601 of 49 CFR United States Code,
conducted an inspection of Northwest Pipeline Corporation (WGP) Sumas District in and near
Sumas, Washington. The WUTC acts as an agent of the Western Region, Pipeline and
Hazardous Material Safety Administration (PHMSA).
As a result of the inspection, it appears that you have committed probable violations of the
Pipeline Safety Regulations, Title 49, Code of Federal Regulations. The items inspected and
the probable violation(s) are:
1. $192. 467 External corrosion control: Electrical isolation.
(c) Except for unprotected copper inserted in a ferrous pipe, each pipeline must be
electrically isolated from metallic casings that are a part of the underground system.
However, if isolation is not achieved because it is impractical, other measures must be
taken to minimize corrosion of the pipeline inside the casing.
(d) Inspection and electrical tests must be made to assure that electrical isolation is
adequate.



The casing under the road crossing of Highway 99 for the 6" diameter Stanwood Lateral is
shorted. WGP had previously installed a dielectric gel between the camer pipe and casing
in an attempt to mitigate this short. However, the short still exists since both the earner
pipe and casing having identical "structure-to-soil" readings of — 1. 095 Volts DC. The
voltage test readings were obtained with a Cu/CuS04 half cell. The test data is listed
below:
Pipe (Volts) ~Costa
Date Location
05/23/2007 6" Stanwood Lateral P/S of the 6" -1 095
line under Highway 99
Comments
-1. 095 The casing was
shorted.
2. $192. 479 Atmospheric corrosion control; General.
(a) Each operator must clean and coat each pipeline or portion of pipeline that is
exposed to the atmosphere, except pipelines under paragraph (c) of this section.
(b) Coating material must be suitable for the prevention of atmospheric corrosion.
(c) Except portions of pipelines in offshore splash zones or soil-to-air interfaces, the
operator need not protect from atmospheric corrosion any pipeline for which the
operator demonstrates by test, investigation, or experience appropriate to the
environment of the pipeline that corrosion will—
(1) Only be a light surface oxide; or
(2) Not affect the safe operation of the pipeline before the next scheduled inspection.
During the field inspection, the pipe coating at the "air-to-soil" transition had failed at two
locations in the Mt. Vernon compressor station. Even though there were no signs of
corrosion under the disbonded coating, the transitions need to be coated m order to prevent
the possibility of external, atmospheric corrosion.
Under 49 United States Code, ) 60122, you are subject to a civil penalty not to exceed
$100, 000 for each violation for each day the violation persists up to a maximum of $1, 000, 000
for any related series of violations. We have reviewed the circumstances and supporting
documents involved in this case, and have decided not to conduct additional enforcement
action or penalty assessment proceedings at this time. We advise you to correct the items
identified in this letter. Failure to do so will result in Northwest Pipehne Corporation (WGP)
being subject to additional enforcement action. No reply to this letter is required. If you
choose to reply, in your correspondence please refer to CPF 5-2007-1012W. Be advised that
all material you submit in response to this enforcement action is sub3ect to bemg made
pubhcly available. If you believe that any portion of your responsive material qualifies for
confidential treatment under 5 U. S. C. 552(b), along with the complete original document you
must provide a second copy of the document with the portions you beheve qualify for



confidential treatment redacted and an explanation of why you believe the redacted
information qualifies for confidential treatment under 5 U. S. C. 552(b).
Sincerely,
j
Chris oidal
Director, Western Region
Pipeline and Hazardous Materials Safety Administration
CC: PHP-60 Compliance Registry
PHP-500 T. Finch (¹118850)
A. Rathbun, P. E.
WUTC
,
D. Lykken, WUTC
Joseph P. Robertson, P. E.
,
Williams Gas Pipeline

## Provenance

- Official: Yes
- Source: <https://primis.phmsa.dot.gov/enforcement-data/case/520071012W>
- Source ID: `phmsa-enforcement`
- SHA-256: `faea77e4de101cc11653a2cb059f2e4051b1f5fec67b3649c687efd33ec06864`
- Retrieved: 2026-08-20T04:44:44.458Z
- Exported: 2026-08-23T10:48:34.652Z
- Document slug: `phmsa-enforcement-520071012w`

### Source metadata

```json
{
  "cpf": "520071012W",
  "operator": "NORTHWEST PIPELINE LLC",
  "region": "Western",
  "pipelineType": "GAS INTERSTATE ONSHORE",
  "caseStatus": "CLOSED",
  "citedSections": [
    "192.467(c)",
    "192.479"
  ],
  "dataAsOf": "08/04/2026 12PM",
  "caseDataAsOf": "2026-08-04",
  "attachmentCount": 2,
  "attachments": [
    {
      "name": "520071012W_warning letter_07092007.pdf",
      "url": "https://primis.phmsa.dot.gov/enforcement-documents/520071012W/520071012W_warning%20letter_07092007.pdf",
      "bytes": 33279,
      "category": "agency_document"
    },
    {
      "name": "520071012w_warning letter_07092007_text.pdf",
      "url": "https://primis.phmsa.dot.gov/enforcement-documents/520071012W/520071012w_warning%20letter_07092007_text.pdf",
      "bytes": 115254,
      "category": "agency_document"
    }
  ],
  "extractedAgencyDocumentCount": 1,
  "attachmentPolicy": "Official attachment links are retained. Agency-issued documents may also include a verified local PDF and page-level text representation.",
  "jurisdiction": "US",
  "operatorName": "NORTHWEST PIPELINE LLC"
}
```