# NORTH SLOPE BOROUGH ENERGY MANAGEMENT — Warning Letter

**Citation:** CPF 520130008W  
**Type / status:** enforcement / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective:** Not stated  
**Published:** 2013-05-23

CLOSED warning letter citing 192.463(a), 192.479.

## Document text

Warning Letter involving NORTH SLOPE BOROUGH ENERGY MANAGEMENT. PHMSA's enforcement data identifies the cited regulations as 192.463(a),  192.479. The case was opened on 2013-05-23 and is reported as closed as of 2013-05-23. Open the official case record for notices, responses, orders, and the latest status.

Official case documents:

520130008W_warning letter_05232013.pdf: https://primis.phmsa.dot.gov/enforcement-documents/520130008W/520130008W_warning%20letter_05232013.pdf

520130008W_warning letter_05232013_text.pdf: https://primis.phmsa.dot.gov/enforcement-documents/520130008W/520130008W_warning%20letter_05232013_text.pdf

520130008W_warning letter_05232013_text.pdf

WARNING LETTER
CERTIFIED MAIL - RETURN RECEIPT REQUESTED
May 23, 2013
Mr. Charles Sakeagak
Director
North Slope Borough Public Works
P.O. Box 350
Barrow, AK 99723
CPF 5-2013-0008W
Dear Mr. Sakeagak:
On April 23-25, 2013, a representative of the Pipeline and Hazardous Materials Safety
Administration (PHMSA), pursuant to Chapter 601 of 49 United States Code, inspected your
procedures and records for the Nuiqsut natural gas transmission pipeline in Nuiqsut, AK.
Field inspection of the gas pipeline was also conducted.
As a result of the inspection, it appears that you have committed probable violations of the
Pipeline Safety Regulations, Title 49, Code of Federal Regulations. The items inspected and
the probable violations are:
1. §192.463 External corrosion control: Cathodic protection.
(a) Each cathodic protection system required by this subpart must provide a
level of cathodic protection that complies with one or more of the applicable
criteria contained in Appendix D of this part. If none of these criteria is
applicable, the cathodic protection system must provide a level of cathodic
protection at least equal to that provided by compliance with one or more of
these criteria.
The North Slope Borough (NSB) failed to provide adequate cathodic protection for the
Nuiqsut natural gas transmission pipeline (NNGP) as required by §192.463 for the years
2011 and 2012. Cathodic protection levels at Test Stations 2, 4, and 7 on the NNGP did not
meet the cathodic protection criteria that are required by Part 192, Appendix D (I (1), I (3),
II, III). The annual cathodic protection reports prepared by your consultant, Taku
Engineering, for the years 2011 and 2012 confirm that Test Stations 2, 4, and 7 did not meet



the -850 mV instant-off potential, nor the 100 mV depolarization, as required by Appendix
D. Therefore, the NSB failed to meet the requirements of §192.463.
2. §192.479 Atmospheric corrosion control; General.
(a) Each operator must clean and coat each pipeline or portion of pipeline that
is exposed to the atmosphere, except pipelines under paragraph (c) of this
section.
(b) Coating material must be suitable for the prevention of atmospheric
corrosion.
(c) Except portions of pipelines in offshore splash zones or soil-to-air
interfaces, the operator need not protect from atmospheric corrosion any
pipeline for which the operator demonstrates by test, investigation, or experience
appropriate to the environment of the pipeline that corrosion will-
(1) Only be a light surface oxide; or
(2) Not affect the safe operation of the pipeline before the next scheduled
inspection.
The NSB failed to protect sections of the NNGP pipeline from atmospheric corrosion as
required by §192.479 (b). The coating on the NNGP pipeline is damaged, specifically at U-
bolt and stress point locations, to the extent that moisture has penetrated beneath the coating
and has corroded the pipeline beyond a light surface oxide. In some sections, the steel surface
has corroded away and in some sections deep pitting could be observed.
In 2010, the NSB performed a coating damage assessment on the NNGP pipeline. The
assessment was performed by QA Services, Inc. The data from this report showed
approximately 150 locations where coating damage had occurred on the NNGP pipeline.
Further, moisture had entered these locations and had caused atmospheric corrosion. Many
pipeline locations sustained damage, specifically at U-bolt locations, due to movement of the
pipeline, which was caused by wind vibration and expansion and contraction of the pipeline.
Since these locations exhibited atmospheric corrosion beyond a light surface oxide, the NSB
failed to meet the requirements of §192.479 (b).
Under 49 United States Code, § 60122, you are subject to a civil penalty not to exceed
$200,000 per violation per day the violation persists up to a maximum of $2,000,000 for a
related series of violations. For violations occurring prior to January 4, 2012, the maximum
penalty may not exceed $100,000 per violation per day, with a maximum penalty not to
exceed $1,000,000 for a related series of violations. We have reviewed the circumstances
and supporting documents involved in this case, and have decided not to conduct additional
enforcement action or penalty assessment proceedings at this time. We advise you to correct
the item(s) identified in this letter. Failure to do so will result in the North Slope Borough
being subject to additional enforcement action.
2



No reply to this letter is required. If you choose to reply, in your correspondence please refer
to CPF 5-2013-0008W and send all documents to our office at 188 W. Northern Lights
Blvd., Suite 520, Anchorage, AK 99503. Be advised that all material you submit in response
to this enforcement action is subject to being made publicly available. If you believe that any
portion of your responsive material qualifies for confidential treatment under 5 U.S.C.
552(b), along with the complete original document you must provide a second copy of the
document with the portions you believe qualify for confidential treatment redacted and an
explanation of why you believe the redacted information qualifies for confidential treatment
under 5 U.S.C. 552(b).
Sincerely,
Dennis Hinnah
Deputy Director, Western Region
Pipeline and Hazardous Materials Safety Administration
cc: PHP-60 Compliance Registry
PHP-500 Jon Strawn (#143384)
3

## Provenance

- Official: Yes
- Source: <https://primis.phmsa.dot.gov/enforcement-data/case/520130008W>
- Source ID: `phmsa-enforcement`
- SHA-256: `d18ca9221430d9a627b70c5c1832edd7f3c3fcb0e16bb651e9a5a2d5f9f3b25c`
- Retrieved: 2026-08-20T04:44:44.458Z
- Exported: 2026-08-23T12:21:06.006Z
- Document slug: `phmsa-enforcement-520130008w`

### Source metadata

```json
{
  "cpf": "520130008W",
  "operator": "NORTH SLOPE BOROUGH ENERGY MANAGEMENT",
  "region": "Western",
  "pipelineType": "GAS INTRASTATE ONSHORE",
  "caseStatus": "CLOSED",
  "citedSections": [
    "192.463(a)",
    "192.479"
  ],
  "dataAsOf": "08/04/2026 12PM",
  "caseDataAsOf": "2026-08-04",
  "attachmentCount": 2,
  "attachments": [
    {
      "name": "520130008W_warning letter_05232013.pdf",
      "url": "https://primis.phmsa.dot.gov/enforcement-documents/520130008W/520130008W_warning%20letter_05232013.pdf",
      "bytes": 93811,
      "category": "agency_document"
    },
    {
      "name": "520130008W_warning letter_05232013_text.pdf",
      "url": "https://primis.phmsa.dot.gov/enforcement-documents/520130008W/520130008W_warning%20letter_05232013_text.pdf",
      "bytes": 12303,
      "category": "agency_document"
    }
  ],
  "extractedAgencyDocumentCount": 1,
  "attachmentPolicy": "Official attachment links are retained. Agency-issued documents may also include a verified local PDF and page-level text representation.",
  "jurisdiction": "US",
  "operatorName": "NORTH SLOPE BOROUGH ENERGY MANAGEMENT"
}
```