# PHMSA Hazmat Incident I-2016090083 — SULFUR DIOXIDE — PINELAND, TX

**Citation:** PHMSA Hazmat Incident I-2016090083  
**Type / status:** incident / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective:** 2016-06-02  
**Published:** Not stated

Serious reporter-submitted hazardous materials transportation incident on 2016-06-02 in PINELAND, TX.

## Document text

PHMSA hazardous materials incident report I-2016090083.
Incident date: 2016-06-02.
Location: PINELAND, TX.
Mode: Highway.
Carrier/reporter: HENIFF TRANSPORTATION.
Shipper: CALABRIAN CORPORATION.
Materials: UN1079; SULFUR DIOXIDE; hazard class 2.3; 0.000001 LGA released.
What failed: Vapor Valve; Weld or Seam.
How failed: Failed to Operate; Cracked.
Reported failure causes: Valve Open; Deterioration or Aging.
Reported result: Vapor(Gas) Dispersion.
Reporter-submitted DOT Form 5800.1 data may be incomplete, corrected, supplemented, or misreported. A record, serious-incident classification, failure description, or relationship to a reporting rule is not a PHMSA causal finding, compliance determination, or finding of a violation.

## Provenance

- Official: Yes
- Source: <https://portal.phmsa.dot.gov/PDFGenerator/getPublicReport/OHMIR_5800-1-PUBLIC?INCIDENTID=3c8e%2BvPAAKn7CUpDT8C3%2BQ%3D%3D>
- Source ID: `phmsa-hazmat-incidents`
- SHA-256: `f9f5df9ccad9c023a5f2520c2f032faa6bda19147ad98669461dd687a0fbeeb7`
- Retrieved: 2026-08-13T12:55:56.545Z
- Exported: 2026-08-26T04:05:06.866Z
- Document slug: `phmsa-hazmat-incident-i-2016090083`

### Source metadata

```json
{
  "materialSubtype": "phmsa_hazmat_serious_incident",
  "reportNumber": "I-2016090083",
  "operatorReported": true,
  "serious": true,
  "finalAgencyFinding": false,
  "eventDescriptionExcluded": true,
  "publicPdfUrl": "https://portal.phmsa.dot.gov/PDFGenerator/getPublicReport/OHMIR_5800-1-PUBLIC?INCIDENTID=3c8e%2BvPAAKn7CUpDT8C3%2BQ%3D%3D",
  "rowCount": 1,
  "carrierReporterNames": [
    "HENIFF TRANSPORTATION"
  ],
  "shipperNames": [
    "CALABRIAN CORPORATION"
  ],
  "routes": [],
  "cities": [
    "PINELAND"
  ],
  "states": [
    "TX"
  ],
  "originCities": [],
  "modes": [
    "Highway"
  ],
  "materials": [
    {
      "identificationNumber": "UN1079",
      "commodityName": "SULFUR DIOXIDE",
      "hazardousClass": "2.3",
      "quantityReleased": "0.000001",
      "unitOfMeasure": "LGA"
    }
  ],
  "packages": [
    {
      "identificationMarkings": "MC 330",
      "outerMaterial": "CARBON STEEL",
      "outerType": null,
      "outerCapacity": "5387.64",
      "outerCapacityUnit": "LGA",
      "outerShipmentCount": "1",
      "outerFailedCount": "1",
      "innerMaterial": null,
      "innerType": null,
      "innerCapacity": "0",
      "innerCapacityUnit": null,
      "innerShipmentCount": "0",
      "innerFailedCount": "0"
    }
  ],
  "reportingRuleContext": [
    "171.15",
    "171.16"
  ],
  "caveat": "Reporter-submitted DOT Form 5800.1 data may be incomplete, corrected, supplemented, or misreported. A record, serious-incident classification, failure description, or relationship to a reporting rule is not a PHMSA causal finding, compliance determination, or finding of a violation.",
  "privacyCaveat": "The public CSV excludes preparer contact fields. Event Description is intentionally excluded from normalized records and search output to reduce incidental personal-information risk.",
  "jurisdiction": "US"
}
```