# ENERGY TRANSFER COMPANY — Hazardous liquid gravity and reporting-regulated-only — incident on 2025-04-21

**Citation:** PHMSA Report 20250046  
**Type / status:** incident / historical  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective:** 2025-04-21  
**Published:** 2025-05-20

Hazardous liquid gravity and reporting-regulated-only incident in NOT WITHIN A MUNICIPALITY, GLASSCOCK County, TX. Reported cause: EQUIPMENT FAILURE. Reported consequences: 0 fatalities, 0 injuries, 25 CRUDE OIL released, $8,000 reported property damage. Operator-reported incident data submitted to PHMSA, generally within 30 days. Records may be supplemented or corrected and do not represent final agency causal findings.

## Document text

Hazardous liquid gravity and reporting-regulated-only incident in NOT WITHIN A MUNICIPALITY, GLASSCOCK County, TX. Reported cause: EQUIPMENT FAILURE. Reported consequences: 0 fatalities, 0 injuries, 25 CRUDE OIL released, $8,000 reported property damage. Operator-reported incident data submitted to PHMSA, generally within 30 days. Records may be supplemented or corrected and do not represent final agency causal findings.

Report number: 20250046.

Operator ID: 32099.

Reported incident date: 4/21/2025 5:44.

Cause detail: PUMP OR PUMP-RELATED EQUIPMENT

Cause detail: ON 04/21/25 AT APPROXIMATELY 05:44, LOCAL ET EMPLOYEE NOTIFIED THE CONTROL CENTER THAT THE LACT SEAL HAD FAILED AND PRODUCT WAS ON THE PUMP PAD. THE CONTROLLER IMMEDIATELY PULLED PERMISSIVE ON 2365 - END WTH 20-8 6INCH GATHERING LINE (INTRASTATE - TAC 8.110(A)(3)). IT WAS DETERMINED THAT THE BEARING ON THE LACT PUMP FAILED CAUSING THE PUMP TO HEAT TO A DEGREE THAT CAUSED THE MECHANICAL SEAL TO FAIL AND CAUSED PRODUCT TO BE RELEASED. APPROXIMATELY 25 BARRELS OF CRUDE OIL WAS RELEASED. CLEAN-UP CONTRACTORS RECOVERED PRODUCT AND REMOVED CONTAMINATED SOIL. THE LEAK WAS REPAIRED BY REPLACING THE SEAL. THE ACCIDENT IS STILL UNDER INVESTIGATION. A SUPPLEMENTAL REPORT WILL BE SUBMITTED ONCE THE ROOT CAUSE FAILURE ANALYSIS IS COMPLETED. SUPPLEMENTAL & FINAL: THE CAUSE OF THE ACCIDENT WAS DUE TO A PUMP-RELATED EQUIPMENT FAILURE. NORMAL WEAR OF THE PUMP BEARINGS CAUSED PUMP TO OVERHEAT LEADING THE SEAL TO FAIL, WHICH ALLOWED PRODUCT TO BE RELEASED. TO PREVENT REOCCURRENCE, A PREVENTIVE MAINTENANCE SCHEDULE FOR THIS PUMP WILL BE ESTABLISHED, AND PROVIDE TRAINING TO PERSONNEL ON PROPER LUBE OIL LEVEL VERIFICATION.

## Provenance

- Official: Yes
- Source: <https://data.transportation.gov/api/views/27nc-rsge/files/28f0a80f-a155-4294-8d1e-1d46f1237896?download=true&filename=Hazardous%20Liquid%20Gravity%20%26%20Reporting-Regulated-Only%20Jul%202020_present.zip>
- Source ID: `phmsa-pipeline-incidents`
- SHA-256: `eede645c9785b85a9aa4d3446d11a2c9e27851c8489e2ad26ec689969f4e92f4`
- Retrieved: 2026-08-13T02:01:25.153Z
- Exported: 2026-08-22T06:34:29.146Z
- Document slug: `phmsa-incident-1cc422aedffd6f3b2273c8a7`

### Source metadata

```json
{
  "recordKind": "pipeline_incident",
  "datasetType": "hazardous_liquid_gravity",
  "datasetLabel": "Hazardous liquid gravity and reporting-regulated-only",
  "datasetPeriod": "Jul 2020_present",
  "report": {
    "number": "20250046",
    "supplementalNumber": "41051",
    "type": "SUPPLEMENTAL FINAL",
    "receivedDate": "2025-05-20",
    "receivedDateRaw": "5/20/2025"
  },
  "operator": {
    "id": "32099",
    "name": "ENERGY TRANSFER COMPANY"
  },
  "incident": {
    "date": "2025-04-21",
    "dateRaw": "4/21/2025 5:44"
  },
  "location": {
    "city": "NOT WITHIN A MUNICIPALITY",
    "county": "GLASSCOCK",
    "state": "TX",
    "postalCode": null,
    "latitude": 31.877997,
    "longitude": -101.771509,
    "type": "ORIGINATED ON OPERATOR-CONTROLLED PROPERTY, BUT THEN FLOWED OR MIGRATED OFF THE PROPERTY",
    "details": {},
    "facilityName": null
  },
  "cause": {
    "category": "EQUIPMENT FAILURE",
    "details": {
      "CAUSE_DETAILS": "PUMP OR PUMP-RELATED EQUIPMENT",
      "NARRATIVE": "ON 04/21/25 AT APPROXIMATELY 05:44, LOCAL ET EMPLOYEE NOTIFIED THE CONTROL CENTER THAT THE LACT SEAL HAD FAILED AND PRODUCT WAS ON THE PUMP PAD. THE CONTROLLER IMMEDIATELY PULLED PERMISSIVE ON 2365 - END WTH 20-8 6INCH GATHERING LINE (INTRASTATE - TAC 8.110(A)(3)). IT WAS DETERMINED THAT THE BEARING ON THE LACT PUMP FAILED CAUSING THE PUMP TO HEAT TO A DEGREE THAT CAUSED THE MECHANICAL SEAL TO FAIL AND CAUSED PRODUCT TO BE RELEASED. APPROXIMATELY 25 BARRELS OF CRUDE OIL WAS RELEASED. CLEAN-UP CONTRACTORS RECOVERED PRODUCT AND REMOVED CONTAMINATED SOIL. THE LEAK WAS REPAIRED BY REPLACING THE SEAL. THE ACCIDENT IS STILL UNDER INVESTIGATION. A SUPPLEMENTAL REPORT WILL BE SUBMITTED ONCE THE ROOT CAUSE FAILURE ANALYSIS IS COMPLETED. SUPPLEMENTAL & FINAL: THE CAUSE OF THE ACCIDENT WAS DUE TO A PUMP-RELATED EQUIPMENT FAILURE. NORMAL WEAR OF THE PUMP BEARINGS CAUSED PUMP TO OVERHEAT LEADING THE SEAL TO FAIL, WHICH ALLOWED PRODUCT TO BE RELEASED. TO PREVENT REOCCURRENCE, A PREVENTIVE MAINTENANCE SCHEDULE FOR THIS PUMP WILL BE ESTABLISHED, AND PROVIDE TRAINING TO PERSONNEL ON PROPER LUBE OIL LEVEL VERIFICATION."
    }
  },
  "consequences": {
    "fatalities": 0,
    "injuries": 0,
    "commodity": "CRUDE OIL",
    "release": "25",
    "propertyDamage": 8000,
    "estimatedOperatorCost": 0,
    "estimatedEmergencyCost": 1000,
    "estimatedEnvironmentalCost": 40000,
    "ignition": "NO",
    "explosion": null,
    "evacuated": 0,
    "raw": {
      "FATAL": "0",
      "INJURE": "0",
      "UNINTENTIONAL_RELEASE_BBLS": "25",
      "EST_COST_PROP_DAMAGE": "8000",
      "PRPTY": "49800"
    }
  },
  "provenance": {
    "viewId": "27nc-rsge",
    "viewUrl": "https://data.transportation.gov/api/views/27nc-rsge",
    "assetId": "28f0a80f-a155-4294-8d1e-1d46f1237896",
    "archiveFilename": "Hazardous Liquid Gravity & Reporting-Regulated-Only Jul 2020_present.zip",
    "archiveSha256": "35ff2f9e6d8f713021b91cd7454e330520c60954110535908c095d9be7d24df4",
    "memberPath": "accident_gravity_reporting_regulated_jul2020_present.txt",
    "memberSha256": "407a257427bbe49c57db94e8a4511c0f024024b36bf3de2bce03c7858f3822dd",
    "rowNumber": 84,
    "rowSha256": "eede645c9785b85a9aa4d3446d11a2c9e27851c8489e2ad26ec689969f4e92f4"
  },
  "caveat": "Operator-reported incident data submitted to PHMSA, generally within 30 days. Records may be supplemented or corrected and do not represent final agency causal findings.",
  "operatorReported": true,
  "finalAgencyFinding": false,
  "jurisdiction": "US",
  "operatorName": "ENERGY TRANSFER COMPANY"
}
```