<<<PAGE 1>>>

of Transportation
U.S. Department
400 Seventh St., S.W.
Washington, D.C. 20590
Special Programs
Research and
Administration
JUN 15 2004
Mr. William Reinike
Ref. No. 04-0111
DOT Focal Point
Kraton Polymers
2982 Washington Boulevard
Belpre, OH 45714-0235
Dear Mr. Reinike:
This is in response to your April 30, 2004 letter requesting clarification of the Hazardous
Materials Regulations (HIMR; 49 CFR Parts 171-180) applicable to the reuse of stainless steel
drums. You state you have five stainless steel drums designed and fabricated with a wall
thickness of 0.104 inches. The drum capacities are 15 and 30 gallons. The drums are equipped
with valves and a pressure gauge, and any applied pressure is low. The drums are to be used in
dedicated service to contain and transport polymer cement by truck between your plant in Ohio
and your research facility in Texas. You have a contract with carrier, but the transport vehicle
may contain freight from other customers.
You ask whether drums used in dedicated service are subject to the leakproofness test in
accordance with § 173.28(b)(2) each time they are refilled or whether periodic testing is an
allowed alternative and whether your contractual agreement meets the intent of "exclusive use"
as stated in the HMR. You ask whether anyone has asked for and received relief from this
specific requirement when using LTL carriers.
The transportation movement as described does not conform to the requirements in § 173.28.
The reuse provisions in § 173.28 require ali packagings and receptacles used more than once to
conform in all respects to the HMR. The exception from leakproofness testing in § 173.28(b)(7)
is intended to apply only to a drum that is in dedicated service and transported in a transport
vehicle under the exclusive use of the refiller. "Exclusive use" means that the transport vehicle
contractual agreement as described does not meet the intent of "exclusive use" as stated in the
loes not contain any material offered by anyone other than the filler of the drums. You
HMR. Therefore, your drums are subject to a leakproofness test prior to reuse.
173-284
040111

<<<PAGE 2>>>

Inquiries concerning exemptions should be addressed to the Office of Hazardous Materials
Exemptions and Approvals, 202-366-4511. The Office of Hazardous Materials Exemptions and
Approvals has not issued any exemptions that relieve the requirement for "exclusive use"
regarding reuse of packagings.
I hope this information is helpful.
Sincerely,
Chief, Standards Development
(Office of Hazardous Materials Standards

<<<PAGE 3>>>

KRATON"
Polymers
Foster
BELPRE PLANT
§173.28
April 30, 2004
§178.104
Mr. Edward Mazzullo
Testing Reuse
Office of Interpretations
Research and Special Programs Administration
04-011/
U.S. Department of Transportation
Washington, D.C. 20590
Dear Mr. Mazzullo:
Reference 173.28(b)(2)(i) and 17.28(b)(7)(iii)
We respectively ask for your help in clarifying two specific regulations affecting the
reuse of open-top stainless steel drums. The following background information may
help explain the questions.
We have 5 stainless steel UN1A2 drums. The drums were custom designed and
fabricated with a wall thickness of 0.104 inches, which exceeds the minimum thickness
requirements found in 173.28(b)(4)(i). Drum capacities are 15 gallons (~57 liters) and
30 gallons (~114 liters). The drums are equipped with valves and a pressure gauge.
Any applied pressure is very low. (Please see attached photos.)
We plan to use the drums in dedicated service to contain and transport polymer cement
by truck between our plant in Ohio and our research facility in Texas. The cement
meets the definition of a flammable liquid, PGII. Sometimes the cement may contain a
corrosive material as a secondary hazard.
Here are my questions:
• 173.28(b)(2)(i): Since the drums are used in a dedicated service, must we apply
the leak-proof test each and every time they are refilled? Or may we apply
periodic testing instead. If periodic testing is permitted, what is the correct
interval for a stainless steel drum with a design like ours?
• 173.28(b)(7)(iii): We ship the loaded drums individually via an LTL carrier.
(Given the distance between our plant and the research facility, the cost of using
a dedicated truckload carrier would be prohibitive.) We have a contract with the
carrier, but the transport vehicle may contain freight from other customers.
Does the contractual agreement: with the carrier meet the intent of "exclusive
use" as stated in the regulation? Has anyone asked for and been granted relief
from this specific requirement when using LTL carriers?
2982 Washington Boulevard • P.O. Box 235 • Belpre, OH 45714-0235
Telephone: 740-423-7571 • Fax: 740-423-2309

<<<PAGE 4>>>

If you need clarification of further information, please contact me direct at
(740) 423-2261 or bill.reinike@kraton.com. As always, I thank you and your staff for
their assistance.
Sincerely,
William (Bill) Reinike
DOT Focal Point
173.28(b)(2)(i) and

## Provenance

- Official: Yes
- Source: <https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2004/040111.pdf>
- Source ID: `phmsa`
- SHA-256: `d6bdcbe6ff4e00c12b687c6c3fd6de7434226a7de22698a795796ec3158f0eca`
- Retrieved: 2026-08-20T00:59:31.977Z
- Exported: 2026-08-23T03:26:38.126Z
- Document slug: `phmsa-interpretation-04-0111`

### Source metadata

```json
{
  "materialSubtype": "interpretation",
  "interpretationArea": "hazardous_materials",
  "representation": "full_text_from_official_pdf",
  "companies": [
    "Kraton Polymers"
  ],
  "individuals": [
    "Mr. William Reinike"
  ],
  "refIds": [
    "04-0111"
  ],
  "catalogDates": [
    "2004-06-15"
  ],
  "catalogParts": [
    173,
    178
  ],
  "catalogRowCount": 2,
  "sourceRecordUrls": [
    "https://www.phmsa.dot.gov/node/49226"
  ],
  "linkedAttachmentUrls": [],
  "unavailableResponseUrls": [],
  "duplicateRepresentationUrls": [],
  "citedSections": [
    "173.28",
    "173.28(b)(2)",
    "178.604",
    "178.104"
  ],
  "catalogPageUrls": [
    "https://www.phmsa.dot.gov/regulations/title49/section/17328",
    "https://www.phmsa.dot.gov/regulations/title49/section/178604"
  ],
  "pdfUrls": [
    "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2004/040111.pdf"
  ],
  "representations": [
    {
      "viewUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2004/040111.pdf",
      "detailUrl": null,
      "detailHtmlPath": null,
      "pdfUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2004/040111.pdf",
      "pdfArtifactPath": "data/sources/phmsa-interpretations/04-0111-fd5f32c07e.pdf",
      "pdfArtifactSha256": "28748b6678a494893354d53ef7dc5e53fcb8ed3210ae17954c75eaeb12f87ef0",
      "extractedTextPath": "data/sources/phmsa-interpretations/04-0111-fd5f32c07e.v2.txt",
      "extractedTextSha256": "58dbda07e917f43de54a07e4592fb7052bf02bec93d3471a74b89ec297895bca",
      "pageCount": 4,
      "extractionVersion": 2
    }
  ],
  "caveat": "Interpretations apply regulations to the facts presented and do not create independently enforceable requirements.",
  "jurisdiction": "US"
}
```