<<<PAGE 1>>>

U.S. Department
of Transportation
Washington, D.C. 20590
400 Seventh Street, S.W.
Pipeline and
Hazardous Materials Safety
Administration
MAR 26 2007
Mr. Paul J. Crook
Ref. No. 07-0047
Safety & Environmental Manager
Fluoro-Seal International
Houston, Texas 77084
16360 Park Ten Place, Suite 325
Dear Mr. Crook:
This responds to your February 20, 2007 letter requesting clarification on Special
Provision 3 in §172.102 of the Hazardous Materials Regulations (HMR; 49 CFR Parts
fluoride, anhydrous, UN 1052", is Hazard Zone B or Hazard Zone C.
171-180). Specifically, you ask whether the appropriate hazard zone for "Hydrogen
As your letter indicates, the entry for "hydrogen fluoride, anhydrous, UN 1052" is
assigned "Special Provision 3" in column 7 of the Hazardous Materials Table (HMT) in
§172.101 of the HMR. Special Provision 3 indicates that the material is poisonous by
inhalation in Hazard Zone C. Special Provision 3 also references §173.116(a) - Class 2,
Assignment of Hazard Zone. Section 173.116(a) states that the hazard zone for a
Division 2.3 material is assigned in Column 7 of the §172.101 table. The criteria
specified in §173.116(a) for assignment of hazard zones are to be used when the
§172.101 table provides more than one hazard zone for a Division 2.3 material, or
indicates that the hazard zone must be determined on the basis of the grouping criteria for
of the HMT; thus, Hazard Zone C is the correct hazard zone designation for this material.
Division 2.3. The hazard zone for hydrogen fluoride, anhydrous is assigned in Column 7
I hope this answers you inquiry.
Sincerely,
Chief, Standards Development
Office of Hazardous Materials Standards
172.101
172:102SP3
070047
173.166(9)

<<<PAGE 2>>>

Boothe
$172.101
fluorn-seal
s ricability
Fluoro-Seal
An ISO 9001 Certified Company
Tuesday, February 20, 2007
Office of Hazmat Standards
Edward Muzzullo,
400 Jih St. SW
US DOT/PHMSA-DHM10
Washington, D.C. 20590
Subject:
Letter of interpretation request for shipping Hydrogen Fluoride
Dear Mr. Muzzullo,
I am writing to get an official letter of interpretation on shipping Hydrogen Fluoride
(anhydrous).
figure one shows that materials in packing group 1 can be either hazard zone A or hazard
According to 172.101, Hydrogen Fluoride (UN 1052) is packing group 1. 173.133,
This section states "This material is poisonous by inhalation in hazard zone C". This
The special provision 3 under column 7 of 172.101 refers to 172.102, special provision 3.
seems to contradict 173.133 figure one. This special provision also refers to 173.116(a)
which is a table showing that Hydrogen Fluoride would be in Hazard Zone B.
Can you please clarify under which hazard zone hydrogen fluoride should be stipped.
Please feel free to contact me if you have any questions on any of the above, or if I can be
of further assistance by phone at (281) 578 1440, fax at (281) 578 3159 or by email at
pcrook@fsicorp.com
Sincerely,
FLUORO-SEAL INTERNATIONAL, L.P.
Pawl s. Crook
Paul J. Crook
Safety & Environmental Manager
ALIENTOWN. PA
ATLANTA, GA BUFFALO.NY
Fluoro-Seal • 16360 Park Ten Place • Suite 325 • Houston, Texas 77084 • 281-578-1440 • Fax 281-578-3159
WEST CHICAGO. IL
COLUMBUS OH HOMERVILLE GA HOUSTON. TN
KANSAS C TY. MO ST. LOUIS. MO YUMA, AZ

## Provenance

- Official: Yes
- Source: <https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2007/070047.pdf>
- Source ID: `phmsa`
- SHA-256: `2c61476b2c1acf6cab3b66b775360915b27fc594984f6c5af55dd58890d52fe4`
- Retrieved: 2026-08-20T00:59:31.977Z
- Exported: 2026-08-23T13:52:03.755Z
- Document slug: `phmsa-interpretation-07-0047`

### Source metadata

```json
{
  "materialSubtype": "interpretation",
  "interpretationArea": "hazardous_materials",
  "representation": "full_text_from_official_pdf",
  "companies": [
    "Fluoro-Seal International"
  ],
  "individuals": [
    "Mr. Paul J. Crook"
  ],
  "refIds": [
    "07-0047"
  ],
  "catalogDates": [
    "2007-03-26"
  ],
  "catalogParts": [
    172,
    173
  ],
  "catalogRowCount": 3,
  "sourceRecordUrls": [
    "https://www.phmsa.dot.gov/node/46566"
  ],
  "linkedAttachmentUrls": [],
  "unavailableResponseUrls": [],
  "duplicateRepresentationUrls": [],
  "citedSections": [
    "172.101",
    "172.102",
    "173.166",
    "173.166(9)",
    "173.116(a)",
    "173.133"
  ],
  "catalogPageUrls": [
    "https://www.phmsa.dot.gov/regulations/title49/section/172101",
    "https://www.phmsa.dot.gov/regulations/title49/section/172102",
    "https://www.phmsa.dot.gov/regulations/title49/section/173166"
  ],
  "pdfUrls": [
    "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2007/070047.pdf"
  ],
  "representations": [
    {
      "viewUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2007/070047.pdf",
      "detailUrl": null,
      "detailHtmlPath": null,
      "pdfUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2007/070047.pdf",
      "pdfArtifactPath": "data/sources/phmsa-interpretations/07-0047-a77b3e4966.pdf",
      "pdfArtifactSha256": "9b87bb106703f06748e3a7f1639126ad76e4f7c797ef1efb69c25fb36e4cd3a0",
      "extractedTextPath": "data/sources/phmsa-interpretations/07-0047-a77b3e4966.v2.txt",
      "extractedTextSha256": "29d307a98cd0c23c215af2bab1d53aa8b1fe6b4069747a68eacd8e3c92595841",
      "pageCount": 2,
      "extractionVersion": 2
    }
  ],
  "caveat": "Interpretations apply regulations to the facts presented and do not create independently enforceable requirements.",
  "jurisdiction": "US"
}
```