<<<PAGE 1>>>

U.S. Department
of Transportation
Pipeline and Hazardous
Materials Safety
Administration
1200 New Jersey Avenue, SE
Washington, D.C. 20590
Mr. John K. Kinast
Environment Engineer
Henry Company
330 Cold Stream Road
Kimberton, PA 19442
Ref. No.: 07-0165
Dear Mr. Kinast:
This is in response to your letter requesting clarification of the Hazardous Materials
Regulations (49 CFR; HMR Parts 171 -1 80) pertaining to the transportation of a Class 3
(flammable liquid) material overcharged with a Division 2.2 (non-flammable) gas in a DOT
39 cylinder. You state that the Class 3 material (hexane) has a flashpoint of -18" F and a
boiling point of 1 13" F and is overcharged with nitrogen at a pressure ranging from 100-1 35
psi. Specifically, you ask whether the filled cylinder may be transported under the proper
shipping description "Compressed gas, n.0.s. 2.2, UN 1956," and whether the package that is
marked and labeled for a Division 2.2 primary hazard class may also be marked and labeled
for the Class 3 subsidiary hazard.
Under the HMR, you must analyze the cylinder contents based on the form in which the
material will be transported. It is our determination that the contents of your cylinder meet
the defining criteria for a Division 2.1 (flammable gas) material and would most
appropriately be assigned "Compressed gas, flammable, n.0.s. (contains hexane), 2.1,
UN1954" for the basic description. We base this determination on the fact that the cylinder
is filled with hexane and then pressurized with nitrogen to 100-135 psi, causing a portion of
the hexane to stay in the gas phase. Based on our calculations, the compressed gas mixture
will produce flammable vapors in the range of 3 - 6% depending on the temperature and
pressure. This is within the range of the flammability limits of hexane, which is 1.2 - 7.7%.
Therefore, the gas phase of the vaporized hexane in the cylinder makes it a Division 2.1
material.
Although not applicable to the above scenario, in response to your question concerning
subsidiary hazards, a material that is additionally determined to have a flammable liquid
subsidiary hazard, regardless of whether the subsidiary hazard is shown in Column (6) of the
Hazardous Materials Table (HMT), must be identified on the shipping paper in accordance
with 5 172.202(a)(3) and shown in the basic description with the numerical subsidiary

<<<PAGE 2>>>

hazard in parentheses following the primary hazard class or division number. With respect
to the marking and labeling for subsidiary hazards, if the subsidiary hazard is not assigned in
Column (6) of the HMT, the package m, nevertheless, be marked for the subsidiary hazard
and must be labeled for the subsidiary hazard.
I hope this information is helpful. Please contact this office if you have additional questions.
Sincerely,
Hattie L. Mitchell
Chief, Regulatory Review and Reinvention
Office of Hazardous Materials Standards

<<<PAGE 3>>>

4
a enry. C O M P A N Y
August 20,2007
Office of Hazardous Materials Standards
Pipeline and Hazardous Materials Safety Administration
Attn: PHH-10,
U.S. Department of Transportation,
400 7th Street SW.,
Washington, DC 20590-0001.
Re: Dual Hazard for Non-Flammable Gas and Flammable Liquid under 49 CFR 173.2a
Dear To whom it may concern:
Henry Company is seeking clarification on the classification, proper shipping name, and
appropriate labeling for an existing product in a new container.
Henry Company is the largest North American manufacturer of roof coatings and cements and is
a world leader in Energy Star & Green Buildings products. Henry Company is the leading
innovator of Building Envelope Systems and understands the principals of integrating AirNapor
Barrier Systems to ensure superior building performance.
Henry Company produces a product, Blueskin Spray Prep which is sold in 5 gallon pails and is
designed to prepare and prime a building foundation in preparation for the application of an
AirNapor Membrane.
We intend to also package this product in DOT 39 containers with a specific gravity of 0.80 and
psi of 100-135. It will be sold under the name of Blueskin Spray Prep Ultra. The container will be
charged with nitrogen gas, which is the mechanism that pushes the product out of the container
through a stand pipe for application; the product is a flammable liquid. The product as shipped
should flow out of the container much like water out of a garden hose. It would not be atomized or
dispersed in a defined spray pattern like an aerosol product. Consequently, if a leak occurred
during shipping or storage, the container should emit a stream rather than a mist or spray. The
stream of liquid should travel a rel~tively short distance compared to a gas and as such, it should
pose a risk like a flammable liquid.
Blueskin Spray Prep Ultra has a flashpoint of -18 degrees Fahrenheit and a boiling point of 113
degrees Fahrenheit. Consequently, under the 49 CFR 173.2a, we believe the classification and
PSN should be the following:
Compressed gas, n.o.s., 2.2, UN 1956
However, we also believe that the hazard for flammable liquid should also be indicated in the
classification, marking and labeling for these products. The HMR, however, does not provide an
obvious authorization for a dual hazard of non-flammable gas (Class 2.2) and flammable liquid
(Class' 3) since this is out of the range of the Precedence of Hazard Table.
Henry Company wants to mark and label this product to reflect both the non-flammable gas and
the flammable liquid hazards in the following manner:
' The storage recommendations for these products contain a reference to NFPA 30 Storage of Flammable
and Combustible Liquids.

<<<PAGE 4>>>

Compressed gas, n.o.s., (contains nitrogen and a flammable liquid), 2.2, UN1956. Can you
provide the appropriate authorization under the HMR to create a subsidiary hazard Class 3 for
Class 2.2?
Henry Company has requested a special emergency permit to allow us to use the following
classification - Compressed gas, n.o.s., (contains nitrogen and a flammable liquid), 2.2, UN1956
- in addition to the marking and labeling for both the Class 2.2 and Class 3 hazards. Please see
attached letter.
If you have any questions at all, please do not hesitate to contact me @ 484.923.2269.
Best regards,
' John K. Kinast
Environmental Engineer
Henry Company 330 Cold Stream Road, Kimberton, PA 19442 (484) 923-2269 FAX (610) 933-2749

<<<PAGE 5>>>

C O M P A N Y
August 20,2007
Associate Administrator for Hazardous Materials Safety
Attention: Special Permits, PHH-31
Pipeline and Hazardous Materials Safety Administration
U.S. Department of Transportation,
400 7th Street SW.,
Washington, DC 20590-0001.
Dear to whom it may concern:
Attached please find the application for special permit, in accordance with 49 CFR 107.105.
Henry Company hereby requests emergency processing of an application for a special permit
under 49 CFR 107.105 and 117 until such time as a letter of interpretation is issued by the
Department of Transportation that.specifically clarifies the classification of our product: Blueskin
Spray Prep Ultra. Please see attached letter.
Emergency processing is requested for the following reasons:
1) Increase safety for 1' responders during transportation emergencies by providing
additional information about a previously unknown hazard. Creating a subsidiary class for
2.2 for class 3.
2) Providing the product in this new container would improve the safety to the contractor
during product application. The product is currently applied with a brush and roller. Spills
and incidents are more possible using 5 gallon pails. Blueskin Spray Prep Ultra new
package will be a pressurized DOT 39 container and there is a significantly less likelihood
of spills or direct exposure.
3) To avoid severe economic financial loss. The Henry Company could incur significant
economic losses up to $1 00,000.
4) To avoid the damage to important business relationships this could be damaged if Henry
Company is unable to launch this product in a new container soon. Our customers of
these products would suffer delays in construction activities.
If there are any questions or any additional information that I can provide to expedite consideration
of this application, pleas* do not hesitate to contact me @ 484.923.2269.
Best regards,
/ John K. Kinast
Environmental Engineer
Henry Company 330 Cold Stream Road, Kirnberton, PA Ic>+J2 6 ( A R . 2 ) 923-2269 FAX (610) 933-2749

<<<PAGE 6>>>

Application for Special Permit
1. Applicant: Henry Company
336 Cold Stream Road
Kimberton, PA 19442
Contact: John Kinast, Environmental Engineer
2. Citation from which the applicant seeks relief: 49 CFR 173.2a(a)
3. Proposed Mode of Transport: HighwayIMotor Carrier
4. Description of the proposed special permit: classification of the product in the following manner:
Blueskin Spray Prep Ultra should be classed as follows: Compressed gas, n.o.s.,
(contains nitrogen and a flammable liquid), 2.2, UN1956
All marking, labeling and placarding should reference both hazards, Class 2.2 and Class 3.
5. Proposed duration of special permit: until such time as a letter of interpretation is received
clarifying the classification of this product.
6. Statement of basis for seeking such relief and description of how compliance will be achieved:
See attached letter requesting interpretation. Compliance will be achieved by adopting the
classification and appropriate marking, labeling and packaging as directed by DOT.
7. Identification of hazardous material planned for transportation under the special permit: See
attached letter of interpretation.
8. Description of packaging to be used with special permit: DOT 39 container.
9. Alternative packaging: no alternative packaging is anticipated.
10. Justlficatron of special permit proposal: This special permit achieves a level of safety that
exceeds that requ~red by the regulation. Class~flcation of this product under the strict confines of
the HMR requires a flnd~ng that the product is a UN 1954, compressed gas, n.o.s., 2.2. However,
this classification fails to indicate the fact that the product expelled by the nitrogen gas is a
flammable liquid. There is no authorization under the HMR to have a product that is a
compressed gas with a flammable liquid hazard. Therefore, to ensure that first responders are
aware of the flammable nature of this product, we believe that it is necessary to classify, mark, -
and label the product as a Class 2.2 with a subsidiary hazard of Class 3.
If a leak occurred during shippirlg or storage, the container would emit a stream rather than a mist
or spray. The stream of liquid should travel a relatively short distance compared to a gas and, as
such, it should pose a risk much like a flammable liquid.'
We are not aware of any previous incidences or other problematic shipping experiences with this
product. There is no increased risk to safety or property that may result if the special permit is
granted. Indeed, we believe that a higher level of safety is achieved in allowing the proposed
classification.
' The storage rcconirnendations for thcse prodjrctc contain a reference to NFPA 30 Storage of Flammable
and Combustible Liquids.

## Provenance

- Official: Yes
- Source: <https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2007/070165.pdf>
- Source ID: `phmsa`
- SHA-256: `f2cc4d4aba3c0b7a912f8dd7f3eecab951be7dc2f91074416c68ed82e6ce3426`
- Retrieved: 2026-08-20T00:59:31.977Z
- Exported: 2026-08-22T12:52:14.384Z
- Document slug: `phmsa-interpretation-07-0165`

### Source metadata

```json
{
  "materialSubtype": "interpretation",
  "interpretationArea": "hazardous_materials",
  "representation": "full_text_from_official_pdf",
  "companies": [
    "Henry Company"
  ],
  "individuals": [
    "Mr. John K. Kinast"
  ],
  "refIds": [
    "07-0165"
  ],
  "catalogDates": [
    "2008-02-08"
  ],
  "catalogParts": [
    173
  ],
  "catalogRowCount": 1,
  "sourceRecordUrls": [
    "https://www.phmsa.dot.gov/node/63951"
  ],
  "linkedAttachmentUrls": [],
  "unavailableResponseUrls": [],
  "duplicateRepresentationUrls": [],
  "citedSections": [
    "173.2a",
    "172.202(a)(3)",
    "107.105"
  ],
  "catalogPageUrls": [
    "https://www.phmsa.dot.gov/regulations/title49/section/1732a"
  ],
  "pdfUrls": [
    "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2007/070165.pdf"
  ],
  "representations": [
    {
      "viewUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2007/070165.pdf",
      "detailUrl": null,
      "detailHtmlPath": null,
      "pdfUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2007/070165.pdf",
      "pdfArtifactPath": "data/sources/phmsa-interpretations/07-0165-dac663bdf9.pdf",
      "pdfArtifactSha256": "93ba877320ebb0b2b091684859c59579668d631691754f13d5f04eb1239b4f23",
      "extractedTextPath": "data/sources/phmsa-interpretations/07-0165-dac663bdf9.v2.txt",
      "extractedTextSha256": "a2e9abd0ac194eb846d8b7863cd3441dcc3c70c379d2c5d8207a0089b732fec5",
      "pageCount": 6,
      "extractionVersion": 2
    }
  ],
  "caveat": "Interpretations apply regulations to the facts presented and do not create independently enforceable requirements.",
  "jurisdiction": "US"
}
```