<<<PAGE 1>>>

U.S. Department
of Transportation
Pipeline and Hazardous
Materials Safety
Administration
1200 New Jersey Avenue, SE
Washington, D.C. 20590
Mr. Robert Savini
Vice President
Lixi, Inc.
1 1980 Oak Creek Pkwy.
Huntley, IL 601 42
Ref No. 07-01 80
Dear Mr. Savini:
This is in response to your letter dated September 1 1,2007 requesting clarification of the
Hazardous Materials Regulations (HMR; 49 CFR Parts 17 1-1 80) applicable to excepted
packages of radioactive materials transported by aircraft. Specifically, you ask whether an
excepted package of UN 291 1 "Radioactive material, excepted package - instruments or
articles" may be transported as carry on or checked baggage on board passenger-carrying
aircraft.
Section 175.75 specifies that, except as provided in the HMR, no person may carry a hazardous
material in the cabin of a passenger-carrying aircraft or on the flight deck of any aircraft, and the
hazardous material must be located in a place that is inaccessible to persons other than crew
members. However, $ 173.422 excepts from the provisions of $ 175.75 -among others - a
package containing a Class 7 material that is prepared for shipments under the requirements
found in §§ 1 73.421, 173.422, 1 73.424, 173.426, and 173.428. Therefore, provided these
requirements are met, there is nothing in the HMR to prohibit a package of UN 291 1
"Radioactive material, excepted package - instruments or articles" from being transported as
carry on or checked baggage on board passenger-carrying aircraft.
It should be noted that the International Civil Aviation Organization's Technical Instructions for
the Safe Transport of Dangerous Goods (ICAO TI) specifically prohibits passengers from
carrying excepted radioactive materials in the cabin or in checked baggage (see ICAO TI 8;
1.1.1). Many commercial airlines follow the International Air Transport Association's (IATA)
Dangerous Goods Regulations which are based on the ICAO TI. Therefore, even in the US,
airlines may choose to prohibit the carriage of excepted radioactive materials in the cabin and
checked baggage based on these ICAO international regulations or IATA industry standards.

<<<PAGE 2>>>

In addition, a US air operator's ability to carry excepted radioactive materials may also be
limited by its operations specifications issued by the Federal Aviation Administration (FAA).
I trust this response satisfies your inquiry.
Sincerely,
[ Chief, Standards Development
Office of Hazardous Materials Standards

<<<PAGE 3>>>

Mr. I:Jtwrd Mazzullo. Ilirecto~
Of'ticc c)f l lazardous 3,tutcrials Standards f DFIM- 10)
Research and Special Pro~mms Admillistration
L!.S. Ihprirtmenl of r'rrinsportation
400 Seventh St.. SW
1Vxhington. DC 20590-0001
Suhject: Clarificatiorl of sllippinp regulatiuns for "excepted packages" of radioactive lnaterial by
domcstic commercial passenger aircraft.
0 t 1 r company. Lixi. Inc.. rnanufacturcs gauging 'and imaging cquiprnent that uscs up tnl Curie of the
radioactivc. isotope (iadtbli ni urn- 1 53 in sealed source form as a gamma source. The exposure control
dei ice. with this source, on our equipn.lent when packaged. conform to the conditions and limitations
specilicd in 49 CFR 173.421 for "Radioactive material, excepted packag -- instnrrncnts or articles,
I'h3911."
In 1984. I.ixi. Inc, ~-equested and received a lettcr (a~tached) from the l1.S. I)c.part~nent of -hnsportation
( I_'SV( 1-1') clarifiit~g that an "esccpted package" of' radioactive nlaterial may be transported on board
pabsenycr carrytrlg aircwti as carry-on or checked biigpgc prot ided it complics L\ ith the applicable
rcquircmcnts under thc I la-arrious Materials Rcgulalions. Hokvebcr. loday we are Jhced ~ i t h the problem
t h t ~ t pcr5onncl ut varicsuu airlines see the LN2911 marking on our pncAugc and refiat: to acticp~ i t LLS
chwhed or cat?-on baggage on passenger aircrctti. I'hey adkise us that we must proccss the packagc as a
cargG sh~prtlant to gel it on the same aircrati as the ptrssenger.
\'c. rrrlilest a response in writing tio~n the L'SDUI that restates cxcepted packages containing i!N 291 1
radioactive material that compl~ uith 49 C'FK Sections 177.321. 173 122. 173.424. and 173.425 ma) bc
tra11spf)rtcd as checked or carry-on baggage on boar~l passenger tarn ing alrcrafi.
-1ri. inc. 11980 0dr Creek Pkwy. Huntley, 1L 60142
a47 961 6606 F 84: 961 6667 ivwi*.lixi.c~rn

<<<PAGE 4>>>

APPENDIX F
Resea~Ch and
Zpeciul Programs
Administration
Mr. Robert 3. Sevini
Executive Vice President
Lixi, Ine.
1438 Brook D r i v e
Downers Grove, f 11 inois 6051 4
Dear Mt., Sevinit
Thank yau for' your Letter o f December 27, 1903, which describes the Lixi-
scope devices c~ntaining a maximum of 500 milBicurie of Iodine 125.
The requirements for such packages are provf ded in 49 CFR Sections 173,422
and 173,423. The informetion in yoor letter indicates that the Lixiscope
packages can comply w i t h these requirements, and i f they ere otherwise
prepared and offered for shipment as required by 49 CFR 173.421-t, the
packages ere excepted from most other requirements o f the Department's
Hazardous Materials Regulations.
A properly packaged tixiscope with the notice required by 49 CFR 173,421-1
may be I q a l l y carried aboard e passenger carrying aircraft es eerry-on or
checked baggage (reference $1 73.421-1 (b) 1.
I hope this informetian is useFlrl t o you and your customers,
Sincerely,
Richard R. Rawl
Chief, Radioactive Branch
Office of Hezsrdous Meteriels
Regul st ion
Materials Traneportatian Bureau

## Provenance

- Official: Yes
- Source: <https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2007/070180.pdf>
- Source ID: `phmsa`
- SHA-256: `ad4eb32e6fafaa6e5c227f559af36e199b9c9517e19804ed4b37c904a033ab44`
- Retrieved: 2026-08-20T00:59:31.977Z
- Exported: 2026-08-27T01:33:06.328Z
- Document slug: `phmsa-interpretation-07-0180`

### Source metadata

```json
{
  "materialSubtype": "interpretation",
  "interpretationArea": "hazardous_materials",
  "representation": "full_text_from_official_pdf",
  "companies": [
    "Lixi, Inc"
  ],
  "individuals": [
    "Mr. Robert Savini"
  ],
  "refIds": [
    "07-0180"
  ],
  "catalogDates": [
    "2007-11-14"
  ],
  "catalogParts": [
    173,
    175
  ],
  "catalogRowCount": 2,
  "sourceRecordUrls": [
    "https://www.phmsa.dot.gov/node/57036"
  ],
  "linkedAttachmentUrls": [],
  "unavailableResponseUrls": [],
  "duplicateRepresentationUrls": [],
  "citedSections": [
    "173.422",
    "175.75",
    "173.426",
    "173.428",
    "173.421",
    "177.321",
    "173.424",
    "173.425"
  ],
  "catalogPageUrls": [
    "https://www.phmsa.dot.gov/regulations/title49/section/173422",
    "https://www.phmsa.dot.gov/regulations/title49/section/17575"
  ],
  "pdfUrls": [
    "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2007/070180.pdf"
  ],
  "representations": [
    {
      "viewUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2007/070180.pdf",
      "detailUrl": null,
      "detailHtmlPath": null,
      "pdfUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2007/070180.pdf",
      "pdfArtifactPath": "data/sources/phmsa-interpretations/07-0180-78b44cb5ad.pdf",
      "pdfArtifactSha256": "6a235a6413a3943e0c02a759098a4178a4ef2c018a331ecf9b6b757898a328a6",
      "extractedTextPath": "data/sources/phmsa-interpretations/07-0180-78b44cb5ad.v2.txt",
      "extractedTextSha256": "3302cff43a4d400def927c218e2a72abd0565e7a4260470da7073f534e447708",
      "pageCount": 4,
      "extractionVersion": 2
    }
  ],
  "caveat": "Interpretations apply regulations to the facts presented and do not create independently enforceable requirements.",
  "jurisdiction": "US"
}
```