# DuPont Sourcing & Logistics — Hazardous Materials Safety Interpretation

**Citation:** 09-0045  
**Type / status:** guidance / guidance  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective:** Not stated  
**Published:** 2009-03-17

09-0045 response to DuPont Sourcing & Logistics concerning 171.22, 171.25.

## Document text

<<<PAGE 1>>>

U.S. Department of Transportation
Pipeline and Hazardous Materials
Safety Administration
1200 New Jersey Ave, S.E.
Wash~ngton, D.C. 20590
Mr. Thomas Reese
DuPont Sourcing & Logistics
Distribution Safety & Security Team
4417 Lancaster Pike, Barley Mill Plaza 2212226
Wilmington, DE 19805
Ref. No. 09-0045
Dear Mr. Reese:
This responds to your February 24,2009 email requesting clarification of international
regulations authorized for use under the Hazardous Materials Regulations (HMR; 49
CFR Parts 17 1 - 180). Specifically, you ask for clarification of whether a portable tank,
containing a Division 2.2 fire extinguishing agent, past the due date for periodic
inspection or testing may be transported in accordance with the International Maritime
Dangerous Goods (IMDG) Code back to the United States to be emptied and retested.
In a follow-up telephone discussion with a member of my staff, you stated that each
portable tank is actually emptied, with_ approximately 3% of the contents remaining in
each tank, and that the tanks are to be shipped back to the United States for periodic
testing. You ask whether your company must comply with both additional conditions
specified in 6.7.3.15.6 of the IMDG Code to be allowed to transport the portable tanks
past the retest date if your company is unable to comply with the general allowance that
permits transportation of portable tanks that are not more than three months past their
retest dates.
The answer is no, you do not need to meet both of the additional conditions specified in
6.7.3.15.6 of the IMDG Code when transporting a portable tank that has passed its retest
date. A portable tank filled prior to its retest date may be transported for a period of not
more than three months beyond the retest date. Along with the general allowance,
6.7.3.15.6 provides for two additional options. A portable tank may be transported past
its retest date after emptying but before cleaning, for purposes of performing the next
required inspection or test (see 6.7.3.15.6.1). Further, a portable tank may be transported
for a period of not more than six months beyond its retest date to allow the return of
hazardous materials for disposal or recycling (see 6.7.3.15.6.2). Thus, your company's
emptied portable tanks may be transported past their retest dates in accordance with

<<<PAGE 2>>>

6.7.3.15.6.1 of the IMDG Code in order to perform the next required inspection or test.
Finally, as authorized by $9 171.22 and 171.25 of the HMR, these portable tanks may be
transported to the United States in accordance with the IMDG Code.
I hope this information is helpful. If you have fwther questions, please do not hesitate to
contact this office.
Sincerely, pd
harles E. ~ k t t s
hief, Standards Development S of Hazardous Materials Standards

<<<PAGE 3>>>

Ber krn devrv, page 1 of2
Drakeford, Carolyn <PHMSA>
_ IXX " XI^IIXXIqw --- a*~w-- --* -- ---*-*- - v I-%
From: Betts, Charles <PHMSA>
Sent: Tuesday, February 24,2009 1 :55 PM 09-00 4
To: Drakeford, Carolyn <PHMSA>
Cc: Kelley, Shane <PHMSA>; Gorsky, Susan <PHMSA>; Pfund, Duane <PHMSA>
Subject: FW: IMDG Code 6.7.3.15.6
Importance: High
Attachments: FE-227 MSDS.pdf; FE-227 Technical Bulletin.pdf; CCRU537029 5-21062005.pdf;
CCRU537218-5-01082005. pdf; ~ ~ ~ ~ 5 3 7 2 5 7 _ 5 _ 1 2 0 7 2 0 0 5 . ~ d f
From: Thomas C Reese [mailto:Thomas.C.Reese-l@USA.dupont.com]
Sent: Tue 2/24/2009 9:38 AM
To: Kelley, Shane <PHMSA>
Subject: IPIDG Code 6.7.3.15.6
To: Shane Kelley - DOT Washington, DC
Good morning Shane. I support DuPont's FluoroChemicals Business which is located in Wilmington, DE. The
business requested me to ask the DOT to send DuPont a letter indicating our three out of test portable tanks
containing residual DuPont FE-227, and currently located in India, are allowed to be shipped back to the United
States to be emptied and retested in accordance with section 6.7.3.15.6 of the IMDG Code. We also request the
letter include a brief paragraph indicating the DOT'S interpretation of the word "and" which appears between
6.7.3.15.6.1 and 6.7.3.15.6.2. Previous communications from the DOT stated the word "and is intended to mean
"or", such that the two conditions are separate and not tied together.
We are asking the DOT to provide this letter because we have not been able to locate a facility in lndia to empty
the tanks, clean them or retest them. Based on experience working with the ocean carriers operating out of India,
we are confident they will refuse a shipment of any out of test tanks containing the residue of a dangerous good
without a letter from the U.S. DOT. Lastly, our personnel located in lndia have tried contacting the Directorate
General of Shipping in lndia to request a variance or a competent authority approval allowing the out of test tanks
to be shipped. They have not had any success.
The following information regarding DuPont FE-227 and the three tanks is provided.
Product lnformation
The product in the portable tanks is CIupontTM FE-2271M Fire Extinguishing Agent.
DG Transport Information
Proper Shipping Name :
Hazard Class :
I.D. No. :
Heptafluoropropane
2 . 2
UN 3 2 9 6
Portable Tank lnformation
Each tank contains 500-600 kilograms (1 102-1322 pounds) FE-227
My address is noted below. If you have any questions, please call me on (302) 992-3483.
Any assistance you can provide to help us resolve this issue quickly is greatly appreciated.

<<<PAGE 4>>>

Page 2 of 2
Have a great day. TomReese
HazMat Regulatory Compliance Consultant
DuPont Sourcing & Logistics
Distribution Safety & Security Team
441 7 Lancaster Pike
Barley Mill Plaza 2212226
Wilmington, DE 19805
Phone: (302) 992-3483 (Ducom 9923483)
FAX: 1-302-355-2891 (This not a Ducorn number)
Internet: Thomas.C.Reese-1 @usa.dupont.com
Hours: 8:00 AM - 5:00 PM
This communication is for use by the intended recipient and contains
information that may be Privileged, confidential or copyrighted under
applicable law. If you are not the intended recipient, you are hereby
formally notified that any use, copying or distribution of this e-mail,
in whole or in part, is strictly prohibited. Please notify the sender by
return e-mail and delete this e-mail from your system. Unless explicitly
and conspicuously designated as "E-Contract Intended", this e-mail does
not constitute a contract offer, a contract amendment, or an acceptance
of a contract offer. This e-mail does not constitute a consent to the
use of sender's contact information for direct marketing purposes or for
transfers of data to third parties.
Francais Deutsch Italiano Espanol Portugues Japanese Chinese Korean

<<<PAGE 5>>>

The MSDS format adheres to the standards and regulatory requirements
of the United States and may not meet regulatory requirements
in other countries.
DuPon t
Material Safety Data Sheet
Page 1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FE-227
6160FR Revised 5-JUN-2006
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CHEMICAL PRODUCT/COMPANY IDENTIFICATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Material Identification
FE-227 is a registered trademark of DuPont.
CAS Number : 431-89-0
Formula : CF3 CHF CF3
Molecular Weight : 170.03
CAS Name : Propane, 1,1,1,2,3,3,3-Heptafluoro-
Tradenames and Synonyms
2-Hydroperfluoropropane
Propane, 1,1,1,2,3,3,3-Heptafluoro-
HFC-227ea
2-Hydroheptafluoropropane
Heptafluoropropane
2-H-heptafluoropropane
1,1,1,2,3,3,3-Heptafluoropropane
Company Identification
MANUFACTURER/DISTRIBUTOR
DuPont Fluoroproducts
1007 Market Street
Wilmington, DE 19898
PHONE NUMBERS
Product Information : 1-800-441-7515 (outside the U.S.
302-774-1000)
Transport Emergency : CHEMTREC 1-800-424-9300(outside U.S.
703-527-3887)
Medical Emergency : 1-800-441-3637 (outside the U.S.
302-774-1000)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
COMPOSITION/INFORMATION ON INGREDIENTS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Component a
Material
1,1,1,2,3,3,3-Heptafluoropropane
Print Date: 8 - 13 - 2006

<<<PAGE 6>>>

DuPont
Material Safety Data Sheet
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HAZARDS IDENTIFICATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
# Potential Health Effects
Based on animal data, exposure to HFC-227ea by inhalation
may cause suffocation, if air is displaced by vapors, and
irregular heart beat with a strange sensation in the chest,
"heart thumping," apprehension, lightheadedness, feeling of
fainting, dizziness, weakness, sometimes progressing to loss
of consciousness and death.
HFC-227ea may cause frostbite if liquid or escaping vapor
contacts the skin.
HFC-227ea may cause "frostbite-likew effects if the liquid
or escaping vapors contact the eyes.
In one study, human volunteers were selected to inhale
HFC-227ea at a concentration of 6000 ppm but the study was
terminated due to a rise in pulse rate that was believed to
be unrelated to the chemical. In a subsequent study with
human volunteers inhaling concentrations up to B O O 0 ppm no
clinically significant effects were observed for any of the
measured laboratory parameters.
Individuals with preexisting diseases of the cardiovascular
system or nervous system may have increased susceptibility
from excessive exposures.
Page 2
Carcinogenicity Information
None of the components present in this material at concentrations
equal to or greater than 0.1% are listed by IARC, NTP, OSHA or ACGIH
as a carcinogen.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FIRST AID MEASURES
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
First Aid
INHALATION
If inhaled, immediately remove to fresh air. If not breathing,
give artificial respiration. If breathing is difficult, give
oxygen. Call a physician.
SKIN CONTACT
Treat for frostbite if necessary by gently warming affected area.
EYE CONTACT
In case of contact, immediately flush eyes with plenty of water
for at least 15 minutes. Call a physician.
Print Date: 8 - 13 - 2006

<<<PAGE 7>>>

DuPont
Material Safety Data Sheet
(FIRST AID MEASURES - Continued)
Page 3
INGESTION
Ingestion is not considered a potential route of exposure.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FIRE FIGHTING MEASURES
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Flammable Properties
1,1,1,2,3,3,3-Heptafluoropropane is not flammable, however
in the presence of a flame or ignition source it may
decompose to form toxic hydrogen fluoride or carbonyl
fluoride.
Extinguishing Media
Use media appropriate for surrounding material.
Fire Fighting Instructions
Self-contained breathing apparatus (SCBA) may be required if
cylinders rupture or release under fire conditions.
Keep cylinders cool with water spray applied from a safe
distance.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ACCIDENTAL RELEASE MEASURES
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safeguards (Personnel)
NOTE: Review FIRE FIGHTING MEASURES and HANDLING (PERSONNEL)
sections before proceeding with clean-up. Use appropriate
PERSONAL PROTECTIVE EQUIPMENT during clean-up.
Evacuate personnel, thoroughly ventilate area, use self-contained
breathing apparatus. Keep upwind of leak - evacuate until gas has
dispersed.
Initial Containment
Use forced ventilation to disperse vapors.
Print Date: 8 - 13 - 2006

<<<PAGE 8>>>

DuPon t
Material Safety Data Sheet
Page 4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HANDLING AND STORAGE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Handling (Personnel)
Do not breathe gas. Avoid contact with eyes, skin, or clothing.
Wash thoroughly after handling. Wash clothing after use.
Storage
Store in a well ventilated place. Store in a cool, dry place.
Keep container tightly closed.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
EXPOSURE CONTROLS/PERSONAL PROTECTION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Engineering Controls
Use only with adequate ventilation. Keep container tightly closed.
Personal Protective Equipment
Wear safety glasses or coverall chemical splash goggles.
RESPIRATORS
Wear NIOSH approved respiratory protection, as appropriate.
PROTECTIVE CLOTHING
Where there is potential for skin contact have available and wear
as appropriate impervious gloves, apron, pants, and jacket.
Exposure Guidelines
Exposure Limits
FE-227
AEL * (DuPont) : 1000 ppm, 8 & 12 Hr. TWA
* AEL is DuPont's Acceptable Exposure Limit. Where governmentally
imposed occupational exposure limits which are lower than the AEL
are in effect, such limits shall take precedence.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PHYSICAL AND CHEMICAL PROPERTIES
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Physical Data
Boiling Point Melting Point Vapor Pressure Liquid Density Critical temperature Critical pressure : -16.4 C (2.5 F)
: -131 C (-204 F)
: 65.7 psia O 25 C (77 F) (453.3 kPa)
: 1.386 g/cm3 O 25 C (77 F) (86.53 lb/ft3)
: 101.6 C (214.9 F)
: 424.7 psia (2930 kPa)
Print Date: 8 - 13 - 2006

<<<PAGE 9>>>

DuPont
Material Safety Data Sheet
(PHYSICAL AND CHEMICAL PROPERTIES - Continued)
Odor
Form
: None.
: Liquified Gas
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
STABILITY AND REACTIVITY
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chemical Stability
Stable at normal temperatures and storage conditions.
Avoid sources of heat or open flame.
Incompatibility with Other Materials
Incompatible with strong reducing agents such as alkali
metals (e.g., sodium, potassium), alkali-earth metals (e.g.,
magnesium, calcium), and powdered aluminum or zinc.
Decomposition
Decomposes by reaction with high temperature (open flames,
glowing metal surfaces, etc.) forming hydrofluoric acid,
carbonyl fluorides, carbon monoxide and carbon dioxide.
Polymerization
Polymerization will not occur.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TOXICOLOGICAL INFORMATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
# Animal Data
Page 5
Inhalation 4 hour LC50: > 788,698 pprn in rats
Repeated exposure of rats by inhalation for 4 weeks at
concentrations up to 50,000 pprn revealed no toxicologically
significant6 effects. The NOEL for this study was 50,000
ppm. A 90-day inhalation study in rats did not find any
exposure related effects at 105,000 ppm. The NOEL for this
study was 105,000 ppm.
Cardiac sensitization, a potentially fatal disturbance of
heart rhythm associated with a heightened sensitivity to the
action of epinephrine, occurred in dogs at 105,000 ppm. The
NOAEL for cardiac sensitization was 90,000 ppm. In a
different study to evaluate cardiac sensitization in dogs,
concentrations of 90,000, 105,000, and 140,000 pprn caused a
dose-related increase in incidence and severity; at 90,000
pprn efffects were minimal or mild in nature.
Inhalation studies of HFC-227ea in rabbits and rats do not
Print Date: 8 - 13 - 2006

<<<PAGE 10>>>

DuPont
Material Safety Data Sheet
(TOXICOLOGICAL INFORMATION - Continued)
suggest developmental toxicity at concentrations up to
105,000 ppm. Tests have shown that HFC-227ea does not cause
genetic damage in bacterial or mammalian cell cultures.
Tests in animals for carcinogenicity or reproductive
toxicity have not been conducted.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DISPOSAL CONSIDERATIONS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Waste Disposal
Treatment, storage, transportation, and disposal must be in
accordance with applicable Federal, State/Provincial, and Local
regulations. Incinerate material in accordance with Federal,
State/Provincial and Local requirements.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TRANSPORTATION INFORMATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Shipping Information
DOT
Proper Shipping Name : Heptafluoropropane
Hazard Class : 2.2
I .D. No. (UN/NA) : UN 3296
DOT Label (s) : Nonflammable Gas
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
REGULATORY INFORMATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
U.S. Federal Regulations
TSCA Inventory Status : Listed.
TITLE I11 HAZARD CLASSIFICATIONS SECTIONS 311, 312
Acute : Yes
Chronic : No
Fire : No
Reactivity : No
Pressure : No
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OTHER INFORMATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NFPA, NPCA-HMIS
NFPA Rating
Health
Flammability
Reactivity
NPCA-HMIS Rating
Health
Page 6
Print Date: 8 - 13 - 2006

<<<PAGE 11>>>

DuPon t
Material Safety Data Sheet
(Continued)
Page 7
Flammability
Reactivity
Personal Protection rating to be supplied by user depending on use
conditions.
The data in this Material Safety Data Sheet relates only to the
specific material designated herein and does not relate to use in
combination with any other material or in any process.
Responsibility for MSDS : MSDS Coordinator
> : DuPont Fluoroproducts
Address : Wilmington, DE 19898
Telephone : (800) 441-7515
# Indicates updated section.
This information is based upon technical information believed to be
reliable. It is subject to revision as additional knowledge and
experience is gained.
End of MSDS
Print Date: 8 - 13 - 2006

<<<PAGE 12>>>

Technical Information
Description
Ever since Halon 1301 was targeted as a serious ozone-
depleting substance, DuPont has been instrumental in
developing and manufactur~ng non-ozone-depleting replace-
ment agents. The most recent addition to DuPont's full line
of Halon replacements is FE-227TM, or heptafluoropropane
(HFC-227ea), which is the world's most widely used in-kind
replacement for Halon 1301 in total flooding applications.
FE-227TM effectively prevents or extinguishes all major
classes of fires and is safe, clean, and electrically nonconduc-
tive. Its boiling point is -16.45'C (2.4"F) making it useful for
total flooding of enclosures at normal ambient temperatures.
FE-227TM as a fire extinguishing composition is disclosed
in U.S. Patent 5,084,190 which is assigned to DuPont. In
addition, DuPont has a license to U.S. patent 5,124,053
which covers a method for extinguishing a fire.
Performance
The extinguishing concentration of FE-227TM on heptane fuel
is 6.7% by volume as determined by the cup burner test.
According to the 2000 edition of National Fire Protection
Association (NFPA) standard 2001, the minimum design con-
centration for Class B fires shall be 1.3 times the cup burner
value. For Class A fuels the minimum design concentration
is 1.2 times the extinguishing concentration for wood and
polymeric materials as tested according to UL 2166, Standard
for Halocarbon Clean Agent Extinguishing System Units.
In comparison to Halon 1301, FE-227TM is a less efficient
extinguishing agent, but this is not unexpected given the
absence of bromine in the molecule. (It is bromine that made
the Halon compounds extremely effective fire extinguishants,
but also made them potent ozone depleters.) To overcome
the lack of bromine, about two times as much FE-227TM must
be used to achieve suppression under equivalent conditions.
This presents no problem in designing and installing new sys-
tems, but makes it unlikely that existing Halon 1301 systems
could simply be refilled with an equal quantity of FE-227TM
and achieve the same level of performance. Nevertheless,
FE-227TM is expected to replace the majority of uses for
Halon 1301.
Applications
FE-227TM has its greatest benefit when used as a total flood-
ing agent to protect high-value critical equipment requiring a
clean (leaves no residue), electrically nonconductive gaseous
agent that is safe for people in the event of exposure. These
applications typically exist in telecommunication facilities,
computer rooms, process control centers and other electro-
mechanical equipment rooms.
A comparison of some properties of FE-227TM to Halon 1301
is in Table 1.
The mlmcles of science-

<<<PAGE 13>>>

Table 1 Toxicity
Properties Comparison Halon 1301 to FE-2271M
FE-2271M has very low acute toxicity by inhalation. As with
many other halocarbons and hydrocarbons, FE-2271M produc-
Halon 1301 FE-2271M es a cardiac sensitization response in experimental screening
stud~es. Thls cardiac sensitization response is observed in
Chemical Formula CF3Br CF3CHFCF3 dogs at approximately 105.000 ppm (10.5% LOAEL), but not
Ozone-Depletion Potential 10 0 at 90,000 ppm (9.0% NOAEL). In 1999, further research
Molecular Weight 148.9 170.03 using an EPA-approved, physiologically-based pharmaco-
kinetic (PBPK) model demonstrated that human exposure
Boiling Point, "C (OF) -57.7 (-72.0) -16.45 (2.3) to FE-227TM for up to 5 minutes at concentrations of up to
Critical Temperature, OC (OF) 67.0 (1 52.6) 101.7 (215) 10.5% v/v would not produce a blood level of FE-2271M as-
Liquid Density at 77"F, Ib/ft3 96.01 86.53 sociated with cardiac sensitization. As with all HFC agents
Vapor Pressure at 77OF, psia 234.8 66.0 used as fire suppressants, human exposure to concentrations
above the NOAEL is limited to 5 minutes in duration.
Heat of Vaporization at
Boiling Point, Btullb 35.5 56.7 No other adverse effects were observed in rats exposed by
Extingu~shing Concentration, inhalation at concentrations of up to 105,000 ppm for up to
Heptane, Cup Burner, vol% 3.5 6.7 90 days.
Acute Toxicity, ALC or 400,000- 2788,000 FE-2271M is not mutagenic.
LC,, Rats; 4 hr-ppm 800,000*
'Estimated values Environmental
FE-2271M or heptafluoropropane (CFJHFCF,) is environmen-
tally acceptable with an ozone-depletion potential (ODP) of
zero, a global warming potential of 2,900, based on a 100-yr
horizon relative to CO,, and an atmospheric lifetime of 36.5
years.
Figure 1. Saturated Vapor Pressure of DuPontTM FE-Z27TM
Temperature, 'C
-23 -12 -1 10 21 32 43 54 66 77 88 99
450 31 03
400 2758
350 241 3
m .- m
* P
a 300 2068
$ $
a 2
* 250 1724
E
P P
0 0
200 - 1379 s -
51 51
$ 150 1034 2
100 689
50 345
0 0
-1 0 10 30 50 7 0 90 110 130 150 170 190 210
Temperature, "F

<<<PAGE 14>>>

In 1994 the EPA rated HFC-227ea as acceptable for use as a
total flooding agent in occupied spaces under their Significant
New Alternatives Policy (SNAP) program.
Availability
FE-227TM is available from DuPont in 150-pound cylinders,
1,200-pound containers and either 37,000-pound tank trailers
or IS0 containers depending upon location. Regional stocks
of FE-227TM are maintained globally in accordance with local
demand.
Materials Compatibility
Selected elastomers were immersed in a liquidlvapor mixture
of FE-227TM for two weeks at room temperature (23'C
[74"F]). Eight of the nine common elastomers exhibited
negligible swelling, weight gain, or hardness change after
exposure. This is shown in Table 2.
Plastics were evaluated in the same manner as the elasto-
mers. Six of the plastics showed negligible effect (weight gain
and surface condition). Results are summarized in Table 3.
Most of the common metals such as steel, cast iron, brass,
copper, tin, lead, and aluminum can be used in contact with
FE-227TM under normal conditions. Vessels storing FE-227TM
should be free of moisture.
Specifications
FE-227TM is of high organic purity and essentially residue-
free, meeting the following quality specifications:
Purity, % by weight, minimum 99.0
Moisture, ppm by weight, maximum 10
Acidity, ppm by weight,
expressed as HCI, maximum
Residue, % by volume, maximum 0.03
Table 2
Elastomer Compatibility
Linear swell, Weight Gain, Hardness Change,
Elastomer % YO units
Butyl
Nordel" EPDM
Neoprene W
NBR
Hypalone CSM
Vitone A
Epichlorohydrin homopolymer
FA polysulfide
HvtreP TPE
Table 3
Plastic Compatibility
Weight Gain, Surface
Plastic % Condition
High-density polyethylene (HDPE) 0.1 1 No Change
Polystyrene (PSI -0.03 No Change
Polypropylene (PP) 0.06 No Change
Acrylonitrile-butadiene-styrene (ABS) -0.03 No Change
Polycarbonate (PC) -0.10 No Change
Polymethyl methacrylate (PMMA) i t
Nylon -0.1 7 No Change
Teflona PTFE 5.23 No Change
"Partly dissolved, deformed, and destroyed

<<<PAGE 15>>>

For further information regarding DuPont Fire Extinguishing Agents, contact:
Americas Asia
DuPont Fluoroproducts
Chestnut Run Plaza 7 0 2 - 1 2 7 4 E
P.O. Box 8 0 7 0 2
Wilmington, DE 1 9 8 8 0
Tel: ( 8 0 0 ) 4 7 3 - 7 7 9 0
DuPont Taiwan, Limited
13F, Hung Kuo Building
167 Tun Hwa North Road
Taipei, Taiwan 1 0 5
ROC
Tel: 8 8 6 - 2 - 2 5 1 44488
Europe
DuPont de Nemours International S.A.
2, Chemin du Pavilion
CH-1218 Le Grand-Saconnex
Geneva, Switzerland
Tel: 4 1 - 2 2 - 7 1 7 - 5 3 7 6
Copyright O2006 DuPont or ~ t s affiliates. All rights reserved.'rhe DuPont Oval Logo, DuPontN, The miracles of science",
Nordel", Hypalonm, V~ton", Hytrelp, Teflon" and FETM, are registered trademarks or trademarks of E. I. du Pont de Nemours and
Company or its affil~ates.
NO PART OFTHIS MATERIAL MAY BE REPRODUCED, STORED I N A RETRIEVAL SYSTEM OR TRANSMITTED IN ANY FORM OR BY
ANY MEANS ELECTRONIC, MECHANICAL, PHOTOCOPYING, RECORDING OR OTHERWISE WITHOUT PERMISSION OF DUPONT.
The information set forth herein is furnished free of charge and is based on technical data that DuPont believesto be reliable.
It is intended for use by persons havingtechnical skill, attheir own discretion and risk. The handling precaution information
contained herein is given with the understanding that those using it will satisfy themselves thattheir particular conditions of
use present no health or safety hazards. Because conditions of product use are outside our control, w e make no warranties,
express or implied, and assume no liability in connection with any use ofthis information. As with any material, evaluation of
any compound under end-use conditions prior to specification is essential. Nothing herein is to be taken as a license to operate
under or a recommendation t o infringe any patents.
(1 1/06) RWJ96 Prlnted In U.S.A
[Replaces. H-88819-21
Reorder No. H-88819-3 The mlmcles of sctence-

<<<PAGE 16>>>

Office - Houston
Tank Container Periodic lnspection Report
Control No 20051283
Date 21 June2005
This certifies that the undernoted tank container has been reinspected in accordance with the regulations indicated.
Note: RIDIADR Certification will be supplied upon request.
Scope: 2% Year lnspection 5 Year lnspection
Place of Inspection: Boasso, Houston
Owner's Serial Number
Owner: Eurotainer
CCRU 537029-6
Manufacturer: CKT Rootselaar
Manufacturer's Serial Number 18339 154129
Applicable Regulations:
X CSC F BC 736 89 I .......................................... " .....................
Ixl M O .... 5 ............................................................................................................................ El AAR 600 ........................................................................... " ........................ " .....................................................
Ixl RIDlADR .... F.%!!?.!! .............................................................................................. TC impact -- -----------" ----" ..----
I BAM ............................. - ..................................................................................................... [xl UlC --..-- 70 --...-..-- -..--.----..---
X TIR NL 5 333 86 I - ................................... " .................................................................. I UN ...................................................................................................... " ....................................................
1 Pressure Relief valves1 lS' f d
Full Flow Rate 480 m3/min 480 m31min
18.5 bar 18.5 bar
Vacuum Seltin
I lns~ections Performed N/A I In Order 1 Comments 1
Internal Inspection i j X
!
External lns~ection I X !
Hydraulic Test 1 1 X I
Pressure: 1 ) 29.7 bar 1
Leak Test i I x i
i
Pressure: i ( 6.9 bar 1
Fittings Inspection 1 x !
Frame lnsoection I i X I
I Decals lns~ection 1 ' X i I I
( Steam Coils Test I I I I
Pressure: I
Comments: I
I Passed inspection
Stamping: I
Main Data Plate: 06 05 LR
I csc plate: 12 07
--
Gold cert 112005

<<<PAGE 17>>>

Lovd's
Office
Houston
Tank Container Periodic Inspection Report
register
Control No
20051563
Date
. 1 Augus: 2005
This certifies that the undernotod tank container has been reinspected in accordance with the regulations indicated.
Note: RIDIADR Certification will be supplied upon request.
Scope:
2¼ Year Inspoction
X 6 Year Inspection
Place of Inspection: STS, Houston
Owner's Serial Number
Owner:
Eurotainer
CCRU 537218-0
Manufacturer:
CKT Rootselaar
Manufacturer's Serial Number
1703 18 19113
Appilcable Regulations:
CSC
F BC 736 89
US-DOT _51
IMO
6
AAR 800
RID/ADR
_F 3757
TC Impact
BAM
UIC
87.
TIR
NL 5 723 93
UN
Tank Information
Toro Weight:
Max. Gross Weighl:
3D 460
Capacity:
8 430
Kg
Inspaction Dates
Dosign Tomp:
16 800
kg...
This Inspection:
Last Hydro Test:
Initlel Hyciro Test:
O6 03
09.93
Witness:
Next Inspeciion Due:
02 08
08 05
Witness:
BV
MAWP
Test Pressure:
55
*C
il.
Witness:
LR
LR
40
Bottom Discharge:
Top Discharge:
18.46
bar
bar
Internal Inspection
inspections Performed
N/A
In Order
Comments
Fusiblo link:
+ no. of closuros in serios:
3
Hydraulic Test
Externat Inspection
Leak Test
Pressure:
Sholl Matorial:
40 bar
Shall Thickness:
Hoads Thickness:
Hoads Materint:
19.11
....mm
Pressure:
Width:
Height:
17.89
_mm
Fitings Inspection
6.0 bar
Frame dimensions: Lenelh:
2D:
8'
Frame Inspection
Docals Inspection
Pressure Relief Valves
por
zie
Stoam Colls Test
Prossure:
Manufacture/Type
Serial Numbor
MT
Full Flow Rate
941
MT.
104
Comments:
Vacuum Selling
Operating Pressure
18.46 bar
Bursting Disc
N
N
18.45 bar
N
N
Early 5 year test as directed by owner: Passed Inspection
Surveyor
Stamping:
M. Stevenson
Data Plate:
08 05 LR
SC Plato:
02 0B
Gold cer 1/2005

<<<PAGE 18>>>

Office Houston
Tank Container Periodic lnspection Report
Control No 20051441
Date 12 July 2005
This certifies that the undernoted tank container has been reinspected in accordance with the regulations indicated.
Note: RlDlADR Certification will be supplied upon request.
Scope: 2% Year lnspection 5 Year lnspection
Place of Inspection: STS, Houston
Owner: Eurotainer
Manufacturer: CKT Tankbouw Rootselaar
-
Owner's Serial Number
CCRU 537257-6
Manufacturer's Serial Number 1703 5719195
Applicable Regulations:
Ixl csc -..E.B!!.?.3s.ss ........................................................................................
El IMO .... 5 .... - ................. - - ................................................................................................. A I R 600 ............................................................................................................................................................
RlDlADR F5017 BV00 - - TC lrnpact
................................................................................................. .......... ........ -----..--- -------------.------
I BAM .......... _ ........... - ......................................... - ................................................................ UIC --.-------.----- 87 -..-. -- ---------..------------------.--
Ixl TIR _..NL5.723..?3 ......................................................................................... 0 UN ............................................................................................................................................................
Witness:
07 05 Witness: LR
lns~ections Performed / N/A In Order 1 Comments
Internal Inspection ; / X i
External Inspection i j I
X !
Hydraulic Test 1
i
i x I
Pressure: 1 40 bar I
Leak Test 1
i I x I
Pressure: j , 1 6.9 bar I
Fittings lnspection 1 1 x 1
Frame Inspection 1 I X
Decals lnspection ,
j j X !
Steam Coils Test
X
Pressure:
I Pressure Relief Valves 1 lst Pd
Manufacturerrrype 1 Gimej 1 Gimeg
Serial Number 1 699 1 692
Full Flow Rate I
Operating Pressure 1 18.45 bar 18.45 bar Hydro test early as directed by owner due to welding of barrels; Passed
Vacuum Setting 1 N N inspection
Bursting Disc 1 N , N
I surveyor I
Main Data Plate: 07 05 LR
01 08
Gold cert 112005

## Provenance

- Official: Yes
- Source: <https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2009/090045.pdf>
- Source ID: `phmsa`
- SHA-256: `cf94ab70af4a55f644cf9e8a2f758960050fb79935c8dbcf5534253a1bf1f499`
- Retrieved: 2026-08-20T00:59:31.977Z
- Exported: 2026-08-23T15:45:47.067Z
- Document slug: `phmsa-interpretation-09-0045`

### Source metadata

```json
{
  "materialSubtype": "interpretation",
  "interpretationArea": "hazardous_materials",
  "representation": "full_text_from_official_pdf",
  "companies": [
    "DuPont Sourcing & Logistics"
  ],
  "individuals": [
    "Mr. Thomas Reese"
  ],
  "refIds": [
    "09-0045"
  ],
  "catalogDates": [
    "2009-03-17"
  ],
  "catalogParts": [
    171
  ],
  "catalogRowCount": 2,
  "sourceRecordUrls": [
    "https://www.phmsa.dot.gov/node/44656"
  ],
  "linkedAttachmentUrls": [],
  "unavailableResponseUrls": [],
  "duplicateRepresentationUrls": [],
  "citedSections": [
    "171.22",
    "171.25"
  ],
  "catalogPageUrls": [
    "https://www.phmsa.dot.gov/regulations/title49/section/17122",
    "https://www.phmsa.dot.gov/regulations/title49/section/17125"
  ],
  "pdfUrls": [
    "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2009/090045.pdf"
  ],
  "representations": [
    {
      "viewUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2009/090045.pdf",
      "detailUrl": null,
      "detailHtmlPath": null,
      "pdfUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2009/090045.pdf",
      "pdfArtifactPath": "data/sources/phmsa-interpretations/09-0045-08e03bb27b.pdf",
      "pdfArtifactSha256": "2b5a9d31339da8f1fd64dec54f13c7d3bb910d7da748c6c2c21e9103fb42d805",
      "extractedTextPath": "data/sources/phmsa-interpretations/09-0045-08e03bb27b.v2.txt",
      "extractedTextSha256": "9b1ea20ac66995613a1228c5348adf5372e8bd10feb1c3f883e3d5002684eb16",
      "pageCount": 18,
      "extractionVersion": 2
    }
  ],
  "caveat": "Interpretations apply regulations to the facts presented and do not create independently enforceable requirements.",
  "jurisdiction": "US"
}
```