# Jacobus Energy — Hazardous Materials Safety Interpretation

**Citation:** 10-0115  
**Type / status:** guidance / guidance  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective:** Not stated  
**Published:** 2011-11-07

10-0115 response to Jacobus Energy concerning 178.320, 180.403, 180.413.

## Document text

<<<PAGE 1>>>

U.S. Department
of Transportation
Pipeline and Hazardous
Materials Safety
Administration
NOV? 2011
Mr. John Klein
Jacobus Energy
11815 West Bradley Road
Milwaukee, WI 53224
Ref. No. 10-0115
Dear Mr. Klein:
I
This responds to your request for clarification on § 180.413 of the Hazardous Materials
Regulations (HMR; 49 CFR Parts 171-180). You ask if an "R" stamp is required when
perfonning welding repair on the discharge and inlet piping to a MC306 or MC406 cargo tank.
Further, you state that the repair or replacemen~ could be part of routine maintenance or as part
ofreplacement during a truck mounted tank chlmgeover to a new cab and chassis. Additionally,
you also ask if this piping is considered to be part ofthe laden retention system ofthe cargo tank.
The answer to both of your questions is no. Repair is defined in § 180.403 as any welding on a
cargo tank wall done to return a cargo tank or acargo tank motor vehicle to its original design
and construction specification, or to a condition prescribed for a later equivalent specification in
effect at the time ofthe repair. Cargo tank wall is defined in § 178.320 as, those parts ofthe
cargo tank that make up the primary lading retention structure, including, shell, bulkheads, and
fittings and, when closed, yield the minimum volume ofthe cargo tank assembly.
Section 180.413 requirements include the "R" stamp when repairing specification cargo tanks.
The piping is not nonnally considered part ofthe cargo tank walL Therefore, any welding that
occurs on the piping is generally not considered a repair nor would it require an "R" stamp.
I hope this answers your inquiry. If you need further assistance, please contact this office.
1200 New Jersey Avenue SE
Washington. DC 20590
BenSupko
Acting Chief, Standards Development Branch
Standards and Rulemaking Division

<<<PAGE 2>>>

Drakeford, Carolyn (PHMSA)
From: Supko, Ben (PHMSA)
Sent: Wednesday, May 26,201012:56 PM
To: Drakeford, Carolyn (PHMSA) (0:'" 01/5
Subject: FW: Letter of Interpretation
Importance: High
Cay-~o !2u1~
From: INFOCNTR (PHMSA)
Sent: Tuesday, February 23, 20104:41 PM
To: Drakeford, Carolyn (PHMSA)
Subject: FW: Letter of Interpretation
Importance: High
Carolyn,
Thanks,
Rob
Attached is a request for written interpretation.
From: JohnKlein@jacobusenergy.com [mailto:JohnKlein@jacobusenergy.com]
Sent: Tuesday, February 23, 2010 4:36 PM
To: INFOCNTR (PHMSA)
Subject: Letter of Interpretation
Importance: High
February 23,2010
Pipeline and Hazardous Materials Safety Administration
East Building, 2nd Floor
1200 New Jersey Ave., NE
Washington, DC 20590
Re: Formal Letter of Interpretation
Dear Sir/Madam
We are requesting a formal letter of interpretation as to whether or not we are required to have an "R" stamp
when performing work (welding - repair) on the discharge and inlet piping to a MC306 or MC406 cargotank.
The repair or replacement could be part ofroutine maintenance or as part of replacement during a truck
mounted tank changeover to a new cab and chassis. In connection to this request we would also like
clarification as to whether or not this piping is considered to be part of the laden retention system of the cargo
tank.
Please contact me if you need additional information. Thank you in advance for your response.
J.D. Klein
Jacobus Energy
11815 West Bradley Road
Milwaukee, WI 53224
1

<<<PAGE 3>>>

John Klein
District ManagerlWisconsin
Jacobus Energy
800-522-6287
414-359-0565 Direct
414-840-3395 Cell
414-359-1666
jklein@jacobusenergy.com
2

## Provenance

- Official: Yes
- Source: <https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretations/2010/100115.pdf>
- Source ID: `phmsa`
- SHA-256: `694e2240c35a2243cac70c1adb17c0e0f3aa4450699d1b05a79afe8f36cd68e1`
- Retrieved: 2026-08-20T00:59:31.977Z
- Exported: 2026-08-22T17:45:06.648Z
- Document slug: `phmsa-interpretation-10-0115`

### Source metadata

```json
{
  "materialSubtype": "interpretation",
  "interpretationArea": "hazardous_materials",
  "representation": "full_text_from_official_pdf",
  "companies": [
    "Jacobus Energy"
  ],
  "individuals": [
    "Mr. John Klein"
  ],
  "refIds": [
    "10-0115"
  ],
  "catalogDates": [
    "2011-11-07"
  ],
  "catalogParts": [
    178,
    180
  ],
  "catalogRowCount": 3,
  "sourceRecordUrls": [
    "https://www.phmsa.dot.gov/node/63981"
  ],
  "linkedAttachmentUrls": [],
  "unavailableResponseUrls": [],
  "duplicateRepresentationUrls": [],
  "citedSections": [
    "178.320",
    "180.403",
    "180.413"
  ],
  "catalogPageUrls": [
    "https://www.phmsa.dot.gov/regulations/title49/section/178320",
    "https://www.phmsa.dot.gov/regulations/title49/section/180403",
    "https://www.phmsa.dot.gov/regulations/title49/section/180413"
  ],
  "pdfUrls": [
    "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretations/2010/100115.pdf"
  ],
  "representations": [
    {
      "viewUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretations/2010/100115.pdf",
      "detailUrl": null,
      "detailHtmlPath": null,
      "pdfUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretations/2010/100115.pdf",
      "pdfArtifactPath": "data/sources/phmsa-interpretations/10-0115-2871b7684d.pdf",
      "pdfArtifactSha256": "390c962f335d0be767c7b91653ca99b52daa6716d1934b8267ada38b224efcc7",
      "extractedTextPath": "data/sources/phmsa-interpretations/10-0115-2871b7684d.v2.txt",
      "extractedTextSha256": "88ff72c57cf3d1df01a795250d9e9e39e0fac837317b19c8608da99fd81f0239",
      "pageCount": 3,
      "extractionVersion": 2
    }
  ],
  "caveat": "Interpretations apply regulations to the facts presented and do not create independently enforceable requirements.",
  "jurisdiction": "US"
}
```