# International Titanium Powder — Hazardous Materials Safety Interpretation

**Citation:** 11-0073  
**Type / status:** guidance / guidance  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective:** Not stated  
**Published:** 2011-08-22

11-0073 response to International Titanium Powder concerning 173.28.

## Document text

<<<PAGE 1>>>

U.S. Deportment 1200 New Jersey Avenue SE
of Transportation Washington. DC 20590
Pipeline and Hazardous
Materials Safety
Administration
AUG 22 2011
Bill Murphy
Supply Chain Specialist
International Titanium Powder
940 South Frontage Road
Suite 2000
Woodridge,IL 60517
Ref. No. 11-0073
Dear Mr. Murphy:
This responds to your March 17,2011 email and subsequent telephone conversation with a
member ofmy staff requesting clarification ofthe packaging reuse provisions of the Hazardous
Materials Regulations (HMR; 49 CFR Parts 171-180). As indicated in your letter, you
manufacture a titanium metal pOWder, which you class and described for transportation as "UN
3089, Metal powders, flammable, n.o.s., 4.1, PG II." The powder is transported in UNIA2
reconditioned steel drums designed to contain solids. The powder is placed in a low-density
polyethylene (LDPE) liner with an inert gas, sealed, and placed inside the steel drum for
transportation. The combination package is transported to an outside entity for processing. The
outside entity unpacks the material, processes the powder, then repackages the material in the
same drum and in the same manner as when it was originally packaged, except the outside entity
uses a new LDPE liner. Specifically, you ask ifthe steel drum is required to be leakproofness
tested prior to reuse in accordance with § 173.28.
The answer is no. Leakproofness testing in § 173.28 applies to a package originally required to
be leakproofness tested. Generally, this is a package intended to contain liquids. Your drum is
not subject to leakproof ness testing under § 173.28 because it is used for solids and the design
was not originally required to be leakproofness tested.
I hope this answers your inquiry. If you need additional assistance, please contact this office
at 202-366-8553.
Sincerely,
~S~
Ben Supko
Chief, Standards Development
Standards and Regulations Division

<<<PAGE 2>>>

£,'ch a1 laLLh
~ "3· 29
Drakeford, Carolyn (PHMSA) Reu,se...
From: INFOCNTR (PHMSA) 11-0073
Sent: Friday, March 18,2011 12:25 PM
To: Drakeford, Carolyn (PHMSA)
Subject: FW: Formal Letter of Interpretation
Hi Carolyn,
Thanks,
Victoria
We received the following request for a letter of interpretation. The caller previously spoke with Scott Merkel.
Victoria Lehman
Hazmat Information Center (HMIC)
Pipeline &Hazardous Materials Safety Administration 1200 New Jersey Avenue, SE,
E21-119 Washington, D.C. 20590
http://phmsa.dot.gov/hazmat/info-center
(202) 366-1035
From: William.Murphy@itponline.com [mailto:William.Murphy@itponline.com]
sent: Thursday, March 17, 20111:16 PM
To: PHMSA HM InfoCenter
Subject: Formal Letter of Interpretation
Dear Sir or Madame;
My company, International Titanium Powder, manufactures a titanium metal powder, UN#3089, flammable metal, hazard
class 4.1, packing group II. We package the powder in UN1A21 Y400 I S reconditioned steel drums, with a LDPE plastic
liner filled with Argon gas, The plastic liner is tied, containing the inert gas and material. The drum is a bolt type, open
head, with newly fabricated lid. The minimum thickness of the drum is .9mm (20 Gauge).
We will transport the combination package to an outside entity, who will discard the liner and manipulate the powder. No
new materials will be introduced. The material will then be repackaged and returned to International Titanium Powder for
warehousing and subsequent sale.
We request clarification of 49 CFR 173.28 with respect to our ability to re-use the identical drum as the outer package on
the return trip without perlorming a leakprofness test. Referencing 49 CFR 173.28 B-7, we read that the non bulk package
can be reused, providing the criterion listed in the section.
Can the original UN1A21 Y400 I S carbon steel drums be considered as acceptable under 49 CFR 173.28 7(C) "Another
material or thickness when approved under the conditions established by the Associate Administrator"?
Bill Murphy
Supply Chain Specialist
International Titanium Powder
(630) 410-0078 (Office)
1

## Provenance

- Official: Yes
- Source: <https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretations/2011/110073.pdf>
- Source ID: `phmsa`
- SHA-256: `680b470e1c2d7abac985116fa1c5549f204ec351a8011980cd9bff24d626cbab`
- Retrieved: 2026-08-20T00:59:31.977Z
- Exported: 2026-08-23T07:47:41.592Z
- Document slug: `phmsa-interpretation-11-0073`

### Source metadata

```json
{
  "materialSubtype": "interpretation",
  "interpretationArea": "hazardous_materials",
  "representation": "full_text_from_official_pdf",
  "companies": [
    "International Titanium Powder"
  ],
  "individuals": [
    "Mr. Bill Murphy er"
  ],
  "refIds": [
    "11-0073"
  ],
  "catalogDates": [
    "2011-08-22"
  ],
  "catalogParts": [
    173
  ],
  "catalogRowCount": 1,
  "sourceRecordUrls": [
    "https://www.phmsa.dot.gov/node/45341"
  ],
  "linkedAttachmentUrls": [],
  "unavailableResponseUrls": [],
  "duplicateRepresentationUrls": [],
  "citedSections": [
    "173.28"
  ],
  "catalogPageUrls": [
    "https://www.phmsa.dot.gov/regulations/title49/section/17328"
  ],
  "pdfUrls": [
    "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretations/2011/110073.pdf"
  ],
  "representations": [
    {
      "viewUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretations/2011/110073.pdf",
      "detailUrl": null,
      "detailHtmlPath": null,
      "pdfUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretations/2011/110073.pdf",
      "pdfArtifactPath": "data/sources/phmsa-interpretations/11-0073-d011fac270.pdf",
      "pdfArtifactSha256": "3b9ed5429262cbee39ebda2fd13606ec0a730ec9f104a44b05c485c667b8b947",
      "extractedTextPath": "data/sources/phmsa-interpretations/11-0073-d011fac270.v2.txt",
      "extractedTextSha256": "b5619f4665c47cc287d92f2c940eb505af8bdaf0708eaff5708cb782e132d2ac",
      "pageCount": 2,
      "extractionVersion": 2
    }
  ],
  "caveat": "Interpretations apply regulations to the facts presented and do not create independently enforceable requirements.",
  "jurisdiction": "US"
}
```