# Bway Corporation — Hazardous Materials Safety Interpretation

**Citation:** 13-0009  
**Type / status:** guidance / guidance  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective:** Not stated  
**Published:** 2013-02-28

13-0009 response to Bway Corporation concerning 178.601.

## Document text

<<<PAGE 1>>>

U.S. Department
of Transportation
Pipeline and Hazardous
Materials Safety
Administration
1200 New Jersey Avenue, SE
Washington, D.C. 20590
FEB ~ 8 10ll
Mr. Harold DePriest
Bway Corporation
3737 Miller Park Drive
Garland, TX 75042
Reference No.: 13-0009
Dear Mr. DePriest:
This is in response to your November 1, 2012 email to the Hazardous Materials Information
Center requesting clarification of the Hazardous Materials Regulations (HMR; 49 CFR Parts
171-180) applicable to the UN specification packaging marking on drums.
You package a 5-gallon open head drum with the UN1A2/Y1.5/50 specification marking. A
customer has asked you to test this container with a sheet of plastic film applied over the pail
curl before applying the lid with a crimper. You have tested this configuration in
accordance with Part 178, Subpart M ofthe HMR and the package has passed the tests. You
ask whether the specification packaging marking would change due to the addition of the
plastic film.
Under the selective testing provisions of§ 178.601(g)(5), Variation 5 allows for a single
packaging that differs from a tested design type only to the extent that the closure device or
gasketing differs from that used in the originally tested design type , may be used without
further testing, provided an equivalent level of performance is maintained subject to the
specific qualifying test conditions.
If the package, with the additional plastic film applied meets the requirements of Variation
5, then the packaging may be used without further testing. The original specification
marking remains applicable and does not need to be changed.
In addition, you are correct that, in accordance with HMR § 178.2(c) you are required to
revise the packaging closure instructions to include the application ofthe plastic film in the
procedure.
I trust this satisfies your inquiry. Please contact us ifwe can be of further assistance.
IT2 ·
Delmer Billitzt.
Senior Regulatory Advisor
Standards and Rulemaking Division

<<<PAGE 2>>>

~b·,~i1
~17 8 ./o66
_o_ra_k_e_fo_r_d_,_c_ar_o.ly_n_(_P_H_M_s_A_) ______________________________________________ __
From:
Sent:
To:
Subject:
INFOCNTR (PHMSA)
Wednesday, January 02, 2013 2:30 PM
Drakeford, Carolyn (PHMSA)
FW: letter of interpretation
Tesh\~
l3 -oooC[
From: INFOCNTR (PHMSA)
Sent: Thursday, November 01, 2012 4:04 PM
To: Drakeford, Carolyn (PHMSA)
Subject: FW: letter of interpretation
Hi Carolyn,
We received the following request for a formal letter of interpretation.
Thanks,
Victoria
From: Harold DePriest [mailto:Harold.Depriest@BWAYCorp.com]
Sent: Thursday, November 01, 2012 11:27 AM
To: INFOCNTR (PHMSA)
Subject: letter of interpretation
I talked to your information center desk today and am asking for a letter of interpretation based on our
conversation. Here is the question.
We currently package a 5-gallon open head using the UN1A2/Y1.5/50 marking. Recently a customer requested
that we test this container, but they wanted us to put a sheet of material
similar to Saran Wrap on the pail curl before applying the lid with a crimper. We have tested this configuration
per the protocol in 178.600 and it passes the testing. I asked what the marking should be since we added the
plastic film. The response I received is that the marking stays the same. We need to add the plastic film and
application procedure to our closing instructions.
I would like a letter of interpretation explaining this. Thanks for your assistance.
Harold DePriest
Bway Corporation
3737 Miller Park Drive
Garland, TX 75042
Harold.depriest@bwaycorp.com
972-535-1116
1

## Provenance

- Official: Yes
- Source: <https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2013/130009.pdf>
- Source ID: `phmsa`
- SHA-256: `3bad51d4478c6f06007c1cb65207233ca61dce24f785d2b82b46eca29e811f75`
- Retrieved: 2026-08-20T00:59:31.977Z
- Exported: 2026-08-24T19:57:01.644Z
- Document slug: `phmsa-interpretation-13-0009`

### Source metadata

```json
{
  "materialSubtype": "interpretation",
  "interpretationArea": "hazardous_materials",
  "representation": "full_text_from_official_pdf",
  "companies": [
    "Bway Corporation"
  ],
  "individuals": [
    "Mr. Harold DePriest"
  ],
  "refIds": [
    "13-0009"
  ],
  "catalogDates": [
    "2013-02-28"
  ],
  "catalogParts": [
    178
  ],
  "catalogRowCount": 1,
  "sourceRecordUrls": [
    "https://www.phmsa.dot.gov/node/53221"
  ],
  "linkedAttachmentUrls": [],
  "unavailableResponseUrls": [],
  "duplicateRepresentationUrls": [],
  "citedSections": [
    "178.601",
    "178.601(g)(5)",
    "178.2(c)",
    "178.600"
  ],
  "catalogPageUrls": [
    "https://www.phmsa.dot.gov/regulations/title49/section/178601"
  ],
  "pdfUrls": [
    "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2013/130009.pdf"
  ],
  "representations": [
    {
      "viewUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2013/130009.pdf",
      "detailUrl": null,
      "detailHtmlPath": null,
      "pdfUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2013/130009.pdf",
      "pdfArtifactPath": "data/sources/phmsa-interpretations/13-0009-23bff18226.pdf",
      "pdfArtifactSha256": "8a0b381652e046935491a515958e875578ce8275d26cfe52865517ccf077c8c9",
      "extractedTextPath": "data/sources/phmsa-interpretations/13-0009-23bff18226.v2.txt",
      "extractedTextSha256": "6486b60e20e78274d5cf4a7154e9df19187daad2e2cd103012b3987fa73e8484",
      "pageCount": 2,
      "extractionVersion": 2
    }
  ],
  "caveat": "Interpretations apply regulations to the facts presented and do not create independently enforceable requirements.",
  "jurisdiction": "US"
}
```