<<<PAGE 1>>>

of Transportation
U.S. Department
1200 New Jersey Avenue SE
Washington. DC 20590
Pipeline and Hazardous
Administration
Materials Safety
JUL 2 9 2015
Ms. Andrea Kornbluth
Regional Counsel, North America
Mihama Corporation
D0 Bellevue Pkwy Ste 18(
Wilmington, DE 19809
Reference No. 15-0022
Dear Ms. Kornbluth:
This is response to your December 30, 2014 e-mail requesting clarification of the Hazardous
Materials Regulations (HMR; 49 CFR Parts 171-180) applicable to Department of
Transportation (DOT) specification 39 (DOT-39) cylinders. In your letter, you reference a
Worthington Cylinder Corporation petition (P-1622) that requested changes to the HMR
related to the size limit for DOT-39 cylinders containing liquefied flammable gases. You
state that you are unable to purchase standard size DOT-39 cylinders for use with refrigerant
gases such as R-32. However, you are aware of cylinders currently being imported into the
Japanese market from China on the basis of approval from the Authorized Testing Inc.'s
Chinese offices. You state these cylinders are being certified without reference to the type of
gas they will contain. You ask if it is an acceptable practice under the HMR to use these
DOT-39 specification cylinders with a 793 cubic inch capacity certified in this way to ship
UN 3252, refrigerant gas R32, classified as a 2.1 flammable gas.
Generally, R-32 refrigerant gases are classified as Liquefied Division 2.1 gases. The
Pipeline and Hazardous Materials Safety Administration (PHMSA) does not believe it is a
safe practice to ship 2.1 liquefied flammable gases in a DOT-39 cylinder exceeding 75 cubic
inches.
Prior to 2002, § 173.304(a)(3), Note 9 appeared in the HMR and limited liquefied flammable
gases in DOT-39 cylinders to a size of 75 cubic inches. In an October 20, 1998 (HM-220D)
[63 FR 58460] Notice of Proposed Rulemaking (NPRM), PHMSA proposed to limit all
liquetied flammable gases in DOT-39 cylinders to 75 cubic inches. This NPRM proposed to
remove Note 9 trom §173.304(a)(3) and apply the 75 cubic inch size limit on DOT-39
cylinders to all liquefied compressed gases (not just flammable) in 173.304(a)(3). PHMSA
received several comments in opposition to extending the 75 cubic inch limit on DOT-39
cylinders to all liquefied compressed gases. PHMSA then published a Final Rule on August
8, 2002 (HM-220D) [67 FR 51625] and, based on comments received from the regulated
community, decided not to expand the 75 cubic inch limit on DOT-39 cylinders containing

<<<PAGE 2>>>

liquefied compressed gases. However, in the process of publishing the Final Rule, PHMSA
inadvertently deleted Note 9 in § 173.304a that limited liquefied flammable gases in DOT-39
cylinders to 75 cubic inches. It was never the intention of PHMSA to remove the 75 cubic
inch limit for liquefied flammable gases in DOT-39 specification cylinders. PHMSA did
receive and accept a petition (P-1622) from Worthington Cylinders to address this error in a
future rulemaking.
I hope this satisfies your request.
Sincerely,
lenn roster
T. Glenn Foster
Chief, Regulatory Review and Reinvention Branch
Standards and Rulemaking Division
2

<<<PAGE 3>>>

•
Andraws
178.45
)
Goodall, Shante CTR (PHMSA)
specification 39
From:
Nickels, Matthew (PHMSA)
non neusable cylinders
Sent:
Wednesday, January 28, 2015 6:02 PM
15-0022
To:
Hazmat Interps
Subject:
FW: DOT-39 Cylinder Question
Attachments:
140929Material Control.pdf; ComplianceCert.pdf; Cylinder filling certificateR32.pdf
Hey Shante/Alice,
Please submit this for a formal letter of interpretation. It involves DOT Petition P-1622 (Mr. Andrews might know), and potentially a
previous international harmonization rulemaking (PHH-13 person).
Thanks,
Matt
-----Original Message--
From: Andrea Kornbluth [mailto:akornbluth@mihama.com]
Sent: Friday, January 16, 2015 11:11 AM
To: Foster, Glenn (PHMSA)
Subject: DOT-39 Cylinder Question
Dear Mr. Foster,
My company is a supplier of U.S.-made DOT-39 NRCs in Japan. We understand from documents such as
DOT Petition P-1622, etc. that the DOT is reviewing its rules on the use of NRCs for newer refrigerants
with lower flammability limits, and that there are safety concerns with the rules as they are currently
written. As a result, we are unable to purchase standard-size NRCs for use with gases such as R-32 at
the moment.
However, these products are currently being imported into the Japanese market from China, on the
basis of approval from Authorized Testing Inc. 's Chinese offices. (Please see the attached
documents.) Authorized Testing is certifying cylinders without reference to the type of gas that they will
contain. We were told that they don't look at what might be silkscreened onto the cylinder, either.
We would like to know if this is an acceptable practice, and if cylinders certified in this way can be
considered safe for use with R-32.
Your input would be very much appreciated.
Thank you,
Andrea Kornbluth
Regional Counsel, North America
Mihama Corporation
646-524-7686
akornbluth@mihama.com
1

<<<PAGE 4>>>

Report NO.: XLD1302
AUTHORIZED TESTING, INC.
RIVERSIDE, CA
CERTIFICATE OF COMPLIANCE
SPECIFICATION DOT-39 CYLINDERS
Date: January 25, 2013
Manufactured for:
Wuyi Xilinde Import And Export Department
Located at:
Baihuashan Industrial Zone, Wuyi, 321200, Zhejiang, China.
Manufactured by:
Located at:
Wuyi Xilinde Machinery Manufacture Co.,Ltd
Baihuashan Industrial Zone,Wuyi, 321200, Zhejiang, China.
DOT Specification:
DOT-39 (49CFR§178.65)
DOT Registration 'M' Number is M 0708.
Size: 9.57 inches outside diameter by 16.54 inches long. Minimum wall thickness: 0.0472 inches.
Calculated Wall Stress: 43,085 psi
Quantity: 24000
Design Test Pressure: 500 psi Marked Service Pressure: 400 psi
Internal Volume: 793 cubic inches (nominal).
Model Number:
RC13-3.45
Production Code: XLD1302
These containers were made by process of joining two press drawn domes by a circumferential furnace brazing
with all permissible attachments were furnace brazed to the vessel body.
The metal used was identified by heat or analysis number as shown on the "Record of Chemical Analysis of
Material for Cylinders" attached hereto.
laminations, and other defects, which might prove injurious to the strength of the cylinder. The processes of
All materials and each cylinder were inspected. All accepted material was found free from seams, cracks,
manuracture and heat treatment (if any) were observed and found acceptable.
Where applicable, all tests prescribed in the following specifications) were made in the presence of the inspector.
I hereby certify that I have determined that cylinders described on this report comply with the requirements of U.S.
Department of Transportation Specification DOT-39.
My record of tests and inspection for each lot covered by this report is attached hereto.
Inspectors Name (print)
LI DE QING
Date: January 25, 2013
Inspectors Signature
Li to ling
Authorized Testing, Inc.
DOT-39 Report

<<<PAGE 5>>>

Report NO.: XLD1302
AUTHORIZED TESTING, INC.
RIVERSIDE, CA
RECORD OF CHEMICAL ANALYSIS OF MATERIAL FOR DOT-39 CYLINDERS
Date: January 25, 2013
Manufactured for:
Wuyi Xilinde Import And Export Department
Manufactured by:
Wuyi Xilinde Machinery Manufacture Co.,Ltd
Material: DC04 (ST14), (DQSK)
Mill Heat
Type
XLD Cast
Number
Analysis
Code
Manufacturing (Shift) Lots
P
S
Mn
ZC130120-1,3,5,7,9,11
LADLE
ZCC13005
ZC130121-1,3,5,7,9,11
ZC130123-1,3,5,7,9,11,13
ZC130122-1,3,5,7,9,11
0.02
0.012
0.006
0.18
537412
ZC130120-1,3,5,7,9, 11
CHECK
ZCC13005
ZC130122-1,3,5,7,9,11
ZC130121-1,3,5,7,9,11
0.023
0.014
0.012
0.256
ZC130123-1,3,5,7,9,11,13
Material Manufacturer and mill analysis by: Baoshan Iron & Steel Co.,Ltd
No.885 Fujin Road,Baoshan District 201900 Shanghai.P.R.China
Check Chemical Analysis by: Zhejiang Sifang Group Co. Ltd.
The originals of the certified mill analysis are in the files of the manufacturers.
The above analyses have been verified to comply with material authorized by the specification.
Inspectors Name (print):
LI DE QING
Date:
January 25, 2013
AUTHORIZED
RESTING INC
Inspectors Signature:
L Do Qing
Authorized Testing, Inc.
DOT-39 Report

<<<PAGE 6>>>

Report NO.:XLD1302
AUTHORIZED TESTING, INC.
RECORD OF PHYSICAL TESTS FOR COMPLETED DOT-39 CYLINDERS
RIVERSIDE, CA
Date: January 25, 2013
Manufactured for:
Wuyi Xilinde Import And Export Department
Manufactured by:
Wuyi Xilinde Machinery Manufacture Co., Ltd
Material: DC04(ST14), (DQSK)
Number
Lot
Quantity
Lot
Burst
Lot Test
Flattening Test
Pressure
All Cylinders
Visual
Pressure (psi)
@ 6t
Test
ZC130120-1
998
1008
Inspection
PASSED
PASSED
ZC130120-3
999
1018
PASSED
PASSED
ZC130120-5
998
1015
PASSED
PASSED
PASSED
ZC130120-7
999
1034
PASSED
PASSED
ZC130120-9
999
1019
PASSED
PASSED
ZC130120-11
999
1013
PASSED
PASSED
ZC130121-1
997
1018
PASSED
PASSED
ZC130121-3
999
1015
PASSED
PASSED
ZC130121-5
998
1016
PASSED
PASSED
PASSED
ZC130121-7
998
1010
PASSED
PASSED
ZC130121-9
999
1039
PASSED
PASSED
ZC130121-11
999
1026
PASSED
PASSED
ZC130122-1
998
1016
PASSED
PASSED
ZC130122-3
999
1032
PASSED
PASSED
ZC130122-5
999
1022
PASSED
PASSED
PASSED
ZC130122-7
999
1013
PASSED
PASSED
ZC130122-9
998
1022
PASSED
PASSED
ZC130122-11
998
1031
PASSED
PASSED
ZC130123-1
998
1039
PASSED
PASSED
ZC130123-3
999
1010
PASSED
PASSED
ZC 130123-5
999
1035
PASSED
PASSED
ZC130123-7
998
1013
PASSED
PASSED
PASSED
ZC130123-9
999
1064
PASSED
PASSED
ZC130123-11
998
1016
PASSED
PASSED
ZC130123-13
36
1018
PASSED
PASSED
Inspectors Name (print)
LI DE QING
Date:
January 25, 2013
Inspectors Signature
I be ling
Authorized Testing, Inc.
DOT-39 Report

<<<PAGE 7>>>

ati/XILINDE-13.01
BG STEEL
BG STEEL
BG STEEL
BG STEEL
BG STEEL
BG STEEL
BG STEEL
BG STEEL
BG STEEL
BG STEEL
Mill
Steel
AUTHORIZED TESTING, ING.
537412
537412
537412
537412
537412
537412
537412
537412
537412
537412
Heat No.
461035702
461035701
461035602
461035601
461035502
461035501
461035402
461035401
461035302
461035301
No.
Coil
BGSAL1209250085700
BGSAL1209250085700
BGSAL1209250085700
BGSAL1209250085700
BGSAL1209250085700
BGSAL1209250085700
BGSAL1209250085700
BGSAL1209250085700
BGSAL1209250085700
BGSAL1209250085700
Cert. No.
Steel Mill
2013-1-15
2013-1-15
2013-1-15
2013-1-15
2013-1-15
2013-1-15
2013-1-15
2013-1-15
2013-1-15
2013-1-15
Received
Date
DOT-39
MATERIAL CONTROL LOG
2013-1-22
2013-1-21
2013-1-21
2013-1-21
2013-1-21
2013-1-20
2013-1-20
2013-1-20
2013-1-20
2013-1-20
Released
Date
2013-1-22
2013-1-22
2013-1-21
2013-1-21
2013-1-21
2013-1-21
2013-1-20
2013-1-20
2013-1-20
2013-1-20
Manufactured
Date/Shift
2.215T/465
12.730T/2673
12.700T/2667
12.250T/2572
12.280T/2578
12.510T/2627
12.730T/2673
12.400T/2604
12.250T/2572
12.410T/2606
Manufactured
Quantity
ZCC13005
ZCC13005
ZCC13005
ZCC13005
ZCC13005
ZCC13005
ZCC13005
ZCC13005
ZCC13005
ZCC13005
Steel Lot No.
XILINDE
Comments
XLD1302

<<<PAGE 8>>>

ZHEJIANG YONGHE REFRIGERANT CO., LTD.
ADDRESS: NO. E-025 DONG GANG INDUSTRIAL DISTRICT QUZHOU, ZHEJIANG, CHINA
CYLINDER FILLING CERTIFICATE
DATE:
INVOCIE No.:
B/L No.:
VESSEL/VOY.:
COMPANY NAME: ZHEJIANG YONGHE REFRIGERANT CO.,LTD.
PRPDUCTION: REFRIGERANT GAS R-32
QUANTITY: 280CYLINDERS (N.W.:) 1960KGS
PRESSURE: 1.7MPA AT25°C
TEMPERATURE:25°C
CYLINDER:DOT CYLINDERS:7.0KG
QUANTITY: 280CYLINDERS
CYLINDER DOT NO: 280CYL ZC130122-1
ZHEJIANG 10X
ZHEJIANG YONGHE REFRIGERANT CO., LTD.

## Provenance

- Official: Yes
- Source: <https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2015/150022.pdf>
- Source ID: `phmsa`
- SHA-256: `a752a81737744cfedc0e8d69a177cbd580c6b1fbe9842ffd6e0e549c7d680b43`
- Retrieved: 2026-08-20T00:59:31.977Z
- Exported: 2026-08-23T14:46:02.207Z
- Document slug: `phmsa-interpretation-15-0022`

### Source metadata

```json
{
  "materialSubtype": "interpretation",
  "interpretationArea": "hazardous_materials",
  "representation": "full_text_from_official_pdf",
  "companies": [
    "Mihama Corporation"
  ],
  "individuals": [
    "MS. Andrea Kornbluth"
  ],
  "refIds": [
    "15-0022"
  ],
  "catalogDates": [
    "2015-07-29"
  ],
  "catalogParts": [
    173
  ],
  "catalogRowCount": 1,
  "sourceRecordUrls": [
    "https://www.phmsa.dot.gov/node/55921"
  ],
  "linkedAttachmentUrls": [],
  "unavailableResponseUrls": [],
  "duplicateRepresentationUrls": [],
  "citedSections": [
    "173.304",
    "173.304(a)(3)",
    "173.304a",
    "178.45",
    "178.65"
  ],
  "catalogPageUrls": [
    "https://www.phmsa.dot.gov/regulations/title49/section/173304"
  ],
  "pdfUrls": [
    "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2015/150022.pdf"
  ],
  "representations": [
    {
      "viewUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2015/150022.pdf",
      "detailUrl": null,
      "detailHtmlPath": null,
      "pdfUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2015/150022.pdf",
      "pdfArtifactPath": "data/sources/phmsa-interpretations/15-0022-dd203666d0.pdf",
      "pdfArtifactSha256": "2a7d81b3ef58cbde97adf1c48e36b6dd2672224093b1ce9f4121b9ba33b950bd",
      "extractedTextPath": "data/sources/phmsa-interpretations/15-0022-dd203666d0.v2.txt",
      "extractedTextSha256": "e0d12d2056b748c8b14cc2985d24371738a53159b36837e637c9cc9c7878e344",
      "pageCount": 8,
      "extractionVersion": 2
    }
  ],
  "caveat": "Interpretations apply regulations to the facts presented and do not create independently enforceable requirements.",
  "jurisdiction": "US"
}
```