# HazMat Resources, Inc. — Hazardous Materials Safety Interpretation

**Citation:** 15-0096  
**Type / status:** guidance / guidance  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective:** Not stated  
**Published:** 2015-12-08

15-0096 response to HazMat Resources, Inc. concerning 178.345.

## Document text

<<<PAGE 1>>>

U.S. Department ·
of Transportation
Pipeline and Hazardous
Materials Safety
Administration
1200 New Jersey Avenue, SE
Washington, D.C. 20590
DEC 0 8 2015
Danny Shelton
President, HazM9-t Resources, Inc.
124 Rainbow Drive, Suite 2471
Livingston, TX 773 99-1024
Ref. No. 15-0096
Dear Mr. Shelton:
This responds to your letter of May 8, 2015 requesting clarification of the marking
requirements for pressure relief devices (PRDs) installed on cargo tank motor vehicles
(CTMVs) under the Hazardous Materials Regulations (HMR; 49 CFR Parts 171-180). Your
questions are paraphrased and answered as follows:
Ql. Regarding§ 178.345-lO(h), may a PRD be marked with a model number comprised
generically of the cargo tank specification number and the maximum allowable
working pressure (MA WP) (e.g., "DOT 407 PRESSURE VENT FOR MA WP 35"),
with knowledge that this model number is used to describe pressure relief devices
having certain variations?
Al. Yes. The HMR do not define the term "model number." Conventional dictionaries
can be used to indicate that a "model number" is an identifier for each type of product
that a manufacturer makes. Therefore, the marking comprised generically of the cargo
tank specification number and MA WP could serve as a model number.
Q2. Do the HMR use the terms "model number" and "part number" interchangeably?
A2. No. The HMR do not use the terms "model number" and "part number"
interchangeably. See Al in regard to the meaning of "model number." Conventional
dictionaries can be used to indicate that a "part number" is an identifier of a particular
part design used to reference that part. A "part number" might be used to identify a
particular part across a variety of manufacturers or other entities.
Q3. Do the HMR require the PRD to be marked with a single flow rating that is specific to
the PRD installed on a given CTMV or do the HMR allow the PRD to be marked with
multiple flow ratings?
A3. The HMR do not state that the PRD must be marked with a single flow rating that is
specific to the PRD. Thus, the HMR allow for the PRD to be marked with multiple
flow ratings based on the conditions of successful flow capacity certification testing

<<<PAGE 2>>>

Q4. A4. Q5. AS. and the certification by a responsible official of the device manufacturer as required by
l 78.345-10(g)(3).
Do the markings on the PRD identified in the roadside inspection report generated
from the State of Ohio meet the requirements of§ 178.345-1 O(h)?
Yes. Based on the documents sent in support of your request, it is the opinion of this
Office that these markings appear to meet the requirements of§ 178.345-lO(h).
Do the markings on the PRD identified as being manufactured by Betts Industries
meet the requirements of§ 178.345-1 O(h)?
Yes. Based on the documents sent in support of your request, it is the opinion of this
Office that these markings appear to meet the requirements of§ 178.345-lO(h).
I hope this answers your inquiry. If you need additional assistance, please contact this Office
again.
Sincerely,
Acting Chief, Standards Development Branch
Standards and Rulemaking Division

<<<PAGE 3>>>

Dodd, Alice (PHMSA)
From:
Sent:
To:
Subject:
Attachments:
Betts, Charles (PHMSA)
Friday, May 08, 2015 11:26 AM
Hazmat Interps
FW: Request for Interpretation
Letter + Supporting Documents.pdf
fyi
From: Danny Shelton [mailto:shelton10104@gmail.com]
Sent: Friday, May 08, 2015 10:47 AM
To: Betts, Charles (PHMSA)
Cc: 'Forbes, William'; shorty@grammerindustries.com; 'Glen Harm'; Fleener, Arthur (FMCSA); 'Brigham A. Mccown'
Subject: Request for Interpretation
Mr. Betts, sorry for the confusion, attached are the supporting documents that were used for this
interpretation request.
Regards
1

<<<PAGE 4>>>

MAY 8,2015
Mr. Charles Betts
Director, Office of Hazardous Materials Standards
U.S. Department of Transportation
Pipeline and Hazardous Materials Safety Administration
East Building, 2nd Floor
Mail Stop: E21-317
1200 New Jersey Ave., SE
Washington, DC 20590
Mr. Betts:
Please accept this letter as an official request for an interpretation of the purpose and intent of
the marking requirements identified in 49 CFR § 178.345-1 O(h). This requirement states the
following: "(h) Marking of pressure relief devices. Each pressure relief device must be
permanently marked with the following:
(h)(l) Manufacturer's name;
(h)(2) Model number;
(h)(3) Set pressure, in psig; and
(h)(4) Rated flow capacity, in SCFH at the rating pressure, in psig."
A wide range of opinions exist among pressure relief device manufacturers as to what
constitutes an acceptable marking requirement that will comply with the requirements stated
above.
Recently a motor carrier was cited during a roadside inspection in Ohio conducted by the Ohio
Public Utilities Commission(OPUC)because the pressure relief device (PRD) failed to indicate
the model number on the vent as required by (h)(2) of 178.345-10. A copy of that inspection
report and photographs taken by the officer to document the violation are attached for your
review. This PRD was manufactured by Girard Equipment, Inc. Also attached for your review
is a document published by Girard Equipment, Inc. which indicates that all the information
required by 49 CFR § 178.345-1 O(h) is present and legible on the pressure relief device. A
copy of these documents are attached for your review.
A cursory review of the website for Girard Equipment, Inc. indicates there are many variations
of PRD's offered for sale by the company. The brochures for three different types of vents are
attached for your review. It appears the vent identified in the Ohio roadside inspection that is
the subject of this report is a DOT 3X407 -AFLT. This number was obtained from the product
information supplied by Girard Equipment, Inc. in an attempt to identify the specific model
number of the PRD that was installed on the cargo tank.
124 RAINBOW DRIVE, SUITE 2471 + LIVINGSTON, TX + 77399-1024 + 5HELTON10104@GMAIL.COM + 423-863-2252

<<<PAGE 5>>>

H1azMat Resources, Inc.
It would appear from the information provided in the product literature for Girard Equipment,
Inc. that in order to get the correct PRD for this particular application one would have to
identify the pressure relief device as a DOT 3X407 - AFLT, not DOT 407 Pressure Vent for
MA WP 25. Girard Equipment, Inc. claims that this is a model number for the vent. One cannot
dispute that "DOT 407 for a 25 MA WP tank" can be a model number but what must be decided,
in my opinion, is the following: If the competent authority intends for the marking on the PRD
to identify the PRD installed on the CTMV such as size (3 inch or 4 inch), connection (thread or
flange) then a specific model number must be used for each PRD, so in effect the model number
is really the part number. This is illustrated very clearly in the Girard Equipment, Inc. product
information where it provides specific part numbers for PRD's with varying configurations.
Please provide answers to the following questions:
1. Is it the intent of the regulations to mark the pressure relief device (PRD) with the model
number of the PRD that is actually ordered like a DOT 3X407 - AFL Tor is it the intent
to simply mark the PRD with a generic number that is the cargo tank specification
number and the MA WP with knowledge that the model number covers both three inch
and 4 inch PRD's with additional variations identified in the part number?
2. Is it the intent of the regulations to use model number/part number interchangeably to
indicate the model number of the actual PRD that is installed on the cargo tank?
3. Is it the intent of the regulations to mark multiple flow ratings on a PRD based on the
size of PRD and the pressure at which the flow rating is calculated and leave it up to the
user to determine the size and test pressure in order to determine if the PRD has
adequate venting capacity or is it the intent of the regulations to mark the flow rating and
venting capacity for the specific PRD that is installed on the cargo tank so there is no
possibility of confusion on the part of the user to determine the flow rating of the PRD
installed on the cargo tank?
4. Are the markings on the PRD identified in the roadside inspection report generated from
the State of Ohio correct and do they meet the requirements of 178.345-1 O(h)?
5. Are the markings on the PRD identified in the attachment identified as Betts Industries
correct and meet the requirements of 178.345-1 O(h)?
124 RAINBOW DRIVE, SUITE 2471 + LIVINGSTON, TX + 77399-1024 + 5HELTON10104@GMAIL.COM + 423-863-2252

<<<PAGE 6>>>

HazM1at Resources, ln.c. \
\. /
'o,'\.o..""-"°< • .._,.,_n..,,_,,.~""''I'"'"
As you can clearly see from the information readily available from manufactures web sites and
other information, manufactures mark PRD's differently. Just because it is different does not
mean it is a violation of the marking requirements. If the violation documented by OPUC is
determined by the competent authority to be a valid violation, it is the opinion of the writer this
is not a motor carrier violation and should have no adverse effect on the motor carrier's CSA
scores. We trust you will find this information helpful and in order, but if you need additional
information or would care to discuss this request in more detail please do not hesitate to contact
HazMat Resources, Inc. at 423-863-2252. We thank you in advance for your consideration to
our request for interpretation.
Regards
Daniel G. Shelton
President, HazMat Resources, Inc.
Cc: Glen Harm, Girard Equipment, Inc.
Mr. Tom Forbes, OPUC
Mr. Charles Whittington, President, Grammer Industies
Mr. Arthur Fleener, HMPM, Midwest Service Center
Mr. Brigham A. McCown, McCown, P.C.
Attachments: Report from Ohio Public Utilities Commission (OPUC) plus supporting
documents
124 RAINBOW DRIVE, SUITE 2471 + LIVINGSTON, TX + 77399-1024 + 5HELTON10104@GMAIL.COM + 423-863-2252

<<<PAGE 7>>>

Report Number:
OH3207302165
Inspection Date:
Ohio DRIVER/VEHICLE EXAMINATION REPORT
4/30/2015
Time Started:
16:08
Inspection Level: II - Walk-Around
HM Inspection Type: Bulk Inspection
Certification Date:
Time Ended: 16:38
VICKERY TRANSPORTATION INC
Driver: SCHEUFLER, CHRISTOPHER A
3956 STATE ROUTE 412
License#: RJ526622
State: OH
VICKERY, OH 43464
Date of Birth:
5/30/1963
USDOT #: 00978059
Phone#: (812)378-3364
MC/MX #: 416055
Fax#:
State#:
Location: ROADSIDE
MilePost:
4
Highway:
County:
us 33
Origin:
HOCKING Destination:
BRISTOL, VA
VICKERY, OH Bill of Lading: 006460446FLE
Cargo: HAZ MAT & GENERAL FREIGHT
Shipper: AZZ GALVANIZING BRISTOL
VEHICLE IDENTIFICATION:
Unit Type Make Year State License# Equipment ID Unit VIN GVWR CVSA# CVSA Issued # OOS Stkr.#
1 TT PBT 2015 IN 1161628 214 1XPBD49X5FD256140 52,000
2 ST CMPT 2014 IN Z83600 613V 2C9LTA2B4EB075664 55,000
BRAKE ADJUSTMENTS: No brake measurements recorded.
VIOLATIONS :
State Citation
Vio Code Section Unit oos Number Verify* Crash Violation Description
--
178.345-10 178.345-10 2 N N N DOT406/407/412 Pressure Relief- Girrard PRD not marked with
model number as required. by 178.345-10(h)
* N - Non-OOS or Driver OOS Violation
HazMat: 8 Corrosive Material,
Placard:
Special Checks:
§ Alcohol/Controlled Substance Check
Conducted by Local Jurisdiction
Size and Weight Enforcement
D EScreening
§ Traffic Enforcement
PASA Conducted Inspection
Drug Interdiction Search
Yes Cargo Tank:
D Post Crash Inspection
D PBBT Inspection
412
Arrests:
Locally Defined Fields:
Placards Displayed (Y/N): Y;Loaded by Carrier (Y/N): Y;Ship Doc Prep by Shipper(Y/N): Y; Haz Class A: 8;1D #A: UN1789;Packing Group A: ll;Gross
Weight A: 1 TT;RQ (A): Y;HW (A): Y;For-Hire Carrier: Y;Driver Address: 2668 CR 290;Driver City: VICKERY; Driver State: OH;Driver Zip:
43464;Photos Taken (YIN): Y;Reason Code: USSP;FMCSA Credentials Verified-YIN: N;CDL Verified (Y/N): Y;FMCSA OOS Order lssued(Y/N): U;HM
Safety Permit Verified(Y/N): N
All violations of the FHMR and FMC SR or Title 49 of the Ohio Revised Code will be reviewed by the PUCO's Transportation Department to determine
whether civil forfeitures should be assessed against any responsible parties in accordance with the penalty provisions of Title 49 of the Ohio Revised Code.
If civil forfeitures are assessed, you will receive a separate notice by mail. These penalties may be assessed to motor carriers, shippers, and/or drivers.
ATTENTION DRIVER: This report must be sent to the motor carrier whose name appears at the top of this inspection report within 24 hours. If the
inspection report cannot be delivered within 24 hours the driver must mail or fax the inspection report to the motor carrier.
ATTENTION MOTOR CARRIER: The motor carrier must examine this report and repair all the vehicle defects/violations noted above -AND- The motor
carrier must sign the Certification of Repairs below and return the signed form to: Public Utilities Commission of Ohio, TASD - 4th floor, 180 E Broad St,
Columbus, OH 43215-3793-0R- Fax (614) 752-9274 within 15 days of the inspection. If." No Violations Were Discovered" then you do not need to return
this report. Failure to return this report with the required certification can result in penalties up to $1,000 per day for each day the violation continues, up to
a total of $10,000. If you have any questions, please contact (614) 466-0429.
MOTOR CARRIER CERTIFICATION OF COMPLETED REPAIRS: The undersigned certifies that all violations noted on this report have been corrected
and action taken to assure compliance with the Federal Motor Carrier Safety & Hazardous Materials Regulations insofar as they are applicable to motor
carriers and drivers. A false certification of repairs is required to be prosecuted with penalties up to $10,000.
Signature of Carrier Official: x Title: Date:
Failure to return this report with the required certification can result in penalties up to $1,000 per day for each day the violation continues, up to a total of
$10,000. .
Report Prepared By:
Badge#:
WT Forbes
3207
Copy Received By: SCHEUFLER, CHRISTOPHER A
Page 1 of2
OH3207302165

<<<PAGE 8>>>

Ohio
DRIVER/VEHICLE EXAMINATION REPORT
Report Number:
Inspection Date:
Time Started:
Inspection Level:
HM Inspection Type:
Driver:
License#:
Date of Birth:
OH3207302165
4/30/2015 Certification Date:
16:08 Time Ended: 16:38
II - Walk-Around
Bulk Inspection
SCHEUFLER, CHRISTOPHER A
RJ526622
5/30/1963
VICKERY TRANSPORTATION INC
3956 STATE ROUTE 412
VICKERY, OH 43464
USDOT #: 00978059
MC/MX #: 416055
State#:
State: OH
Phone#: (812)378-3364
Fax#:
Signature of Repairer:
x
Facility:
Date:
Report Prepared By:
WT Forbes
Badge#:
3207
Copy Received By: SCHEUFLER, CHRISTOPHER A
Page 2 of 2
OH3207302165

<<<PAGE 9>>>

Road Side Inspection Photos -April 30, 2015@ 16:08 PM
General View of Vent

<<<PAGE 10>>>

Road Side Inspection Photos - April 30, 2015 @ 16:08 PM
Vent on the tank-Set Pressure and rated flow 178.345-10(h)(3) & (4)

<<<PAGE 11>>>

a Girard Equipment, Inc. Engineering Technical Bulletin
Information Regarding Pressure Relief Devices
Manufactured to 49CFR178.345-10
49CFR178.345-10 (h} Marking of pressure relief devices. Each pressure relief device must be permanently marked with
the following: (1) Manufacturer's name; (2) Model number; (3) Set pressure, in psig; and (4) Rated flow capacity, in SCFH
at the rating pressure, in psig.
h1.
Manufacturer's
Name
h2. The
Model
Number-
DOT407
Pressure Vent
forMAWP25
h4. This h3. This
number marking on
indicates the the Rating
rated/low Disc is the
capacity. Vent's Set
Pressure.
Girard Equipment, Inc. - 4360 Old Dixie Hwy, Vero Beach, FL 32967 - (908) 862-6300 - www.girardequip.com

<<<PAGE 12>>>

FUNCTION AND PURPOSE
Girard Equipment Pressure Relief Vents are now available
with a 4-inch or 3-inch Swivel Connection. This valve was
designed to allow easy positioning of air inlet assemblies
and/or pressure gauges. Pressure Only and Pressure/
Vacuum styles are available. All common repair parts are
interchangeable with all other styles of Girard DOT 407 Vents.
MATERIALS OF CONSTRUCTION
All metallic parts Stainless Steel
"O" Ring Teflon® encapsulated silicone
Gasket Teflon®
PERFORMANCE SPECIFICATIONS (3" Design)
MAWP TEST FLOW EXPOSED
PRESSURE (SCFH) SURFACE
25 40 372,844 732
25 45 408,485 860
30 45 408,485 860
35 52.5 460,443 1061
e..--····-··········--··· (/)7 1.':." --··-················ -·-!
PERFORMANCE SPECIFICATIONS (4" Design)
MAWP TEST FLOW
PRESSURE (SCFH)
25 40 374,512
25 45 431,308
30 45 431,308
35 52.5 484,718
EXPOSED
SURFACE
737
946
946
1156
Vacuum Performance
3,726 SCFH AT 6" HG (EQUIVALENTTO 584 GPM)
INSTANT OPENING AT 4" HG
~~~~~~~~~~15~~~~~~~~~~
AVAILABLE CONNECTION STYLES
3-lnch DDT 407 Combo Vent with Swivel Connection
For Combination Pressure/Vacuum Vents, please add '-WV' to the part number, e.g. DOT3X407TWV-SVL.
3" CONNECTIONS
D OT3X407T-SVL 3" NPT Swivel Connection 25# MAWP
D OT3X407T1 -SVL 3" NPT Swivel Connection 30# MAWP
D OT3X407T2-SVL 3" NPT Swivel Connection 35# MAWP
D OT3X407T3-SVL 3" NPT Swivel Connection, Special Pressure Setting (Please Specify)
4" CONNECTIONS
DDT407LT-SVL 4" NPT Swivel Connection 25# MAWP
DDT407LT1-SVL 4" NPT Swivel Connection 30# MAWP
DDT407LT2-SVL 4" NPT Swivel Connection 35# MAWP
DOT407LT3-SVL 4" NPT Swivel Connection, Special Pressure Setting (Please Specify)
Above vents include a%" Air Accessory Package which contains part numbers: 202016, 202017, 202018, 202019, 202021, 202022
12 www.girardequip.com •Linden, NJ• Houston, TX •Chicago, IL• (800) 526-4330 • gsales@girardequip.com

<<<PAGE 13>>>

Parts And Ordering Information 402019
-
Parts for Pressure Only ( 402003L l
Parts for Pressure I
Vacuum Combination Vents
[
402004L
[
~
T
D 11
GB25010 402005
AGB25000
ITII GR05010 I GR05000
GR06000
{. , 402006V
= GE201005TS
.l.GB09000
c.. ")
402006LN
,--J ~
GB50000
3" Swivel 4" Swivel
www.girardequip.com •Linden, NJ• Houston, TX •Chicago, IL• (800) 526-4330 • gsales@girardequip.com 13

<<<PAGE 14>>>

FUNCTION
Our Low Profile DOT 407 Vent combines a low profile, light
weight design with increased flow rates to meet the most
demanding needs of virtually any DOT 407, DOT 412, MC 307
and MC 312 tank. See the table below for specific flow rates.
The stainless steel valve seat seals on a Teflon®
encapsulated silicone "O" Ring. This "O" Ring provides
complete chemical resistance and a bubble-tight seal to meet
the latest DOT requirements. The unit also meets the surge
requirements of 178.345-10 (b) (3).
DOT 407 LT:
Weight 11.95 lbs.
Installed Height: ~
5 1/2" over the top
of the pipe nipple.
__ L::::::.::::!:::::::::::!::::~-- 6"
~_J
---712"0.D. ___ ,
402011L
d
I I
'
~ I
=
i Gasket4TR
DOT407LT
Vent with a 4" N.P.S. female
pipe thread. Attaches to
a 4" pipe nipple and seals
against a solid Teflon® ring
gasket.
402012L
I
I
DOT 407LS
Stub end vent. Lower housing
terminates in a straight stub
end. Designed to be welded
to the tank shell.
402014L
I 10 CD
l 01
i Gasket 4CFE
DOT407LF
Vent to mount on a 4" TIMA
flange. Supplied with a 3/8" -
16 removable thread inserts
and a Teflon® envelope
flange gasket.
402015L
Gasket 402016
DOT407LAF
Vent to mount on a 4" ANSI
flange. Supplied with a
Teflon® envelope flange
gasket and a 1/4" NPT
"Tell-Tale" indicator tap.
PERFORMANCE SPECIFICATIONS
MAWP TEST FLOW EXPOSED
PRESSURE (SCFH) SURFACE
25 40 374,512 737
25 45 431,308 946
30 45 431,308 946
35 52.5 484,718 1156
i----9"0.D. ----...i
MATERIALS OF CONSTRUCTION
All metallic parts Stainless Steel
"O" Ring Teflon® encapsulated silicone
Gasket Teflon®
www.girardequip.com •Linden, NJ, 800.526.4330 •Houston, TX, 281.842.7500 •Chicago, IL 847.599.8566 5

<<<PAGE 15>>>

ITEMS PART NUMBER DESCRIPTION 'tIIJ'
402019 Plug
2 402003L Rain Cover
2 ( J
3 402004L Low Profile Upper Housing
Specify MAWP
4 402005 Spring (for MAWP < 45 only)
402005HP Spring (for MAWP > 45 only)
5 402006LN Low Profile Poppet with [ ]
Spring Retainer (sold with
GB25010) 3
5A GB25010 Spring Retainer for Pressure
Only Vents (sold separately)
6 402007 Teflon® Silicone "O" Ring
5A
402011L
7 4" LT Model Lower Housing il 8 4TR Solid Teflon® Gasket 4
9 402012L LS Model Lower Housing 5
10 402014L 4" LF Model Lower Housing 6 1
11 4CFE Teflon® Encapsulated
Flange Gasket (TIMA)
+ ~ 9
12 402015L 4" LAF Model Lower Housing
I
13 402016 Teflon® Envelope I
Flange Gasket (ANSI) 8
11
c:=======i13
Repair And Disassembly: The disassembly feature was designed to allow users to easily disassemble the vent in one minute.
1) Remove the Plug.
2) Insert the T-Wrench
into the nut of the
Poppet.
3) Tighten the Lifting Nut.
4) Remove the Upper
Housing.
5) Remove and replace
the "O" Ring.
6
www.girardequip.com •Linden, NJ, 800.526.4330 •Houston, TX, 281 .842.7500 •Chicago, IL 847.599.8566

<<<PAGE 16>>>

FUNCTION
Girard Equipment, lnc.'s Teflon® lined Pressure Relief Valve
is designed to protect against aggressive ladings that normally
would chemically attack stainless steel.
All wetted surfaces are lined with a Ys" thick Teflon® liner.
The valve seat seals on a Teflon® encapsulated silicone "O"
Ring. This "O" Ring provides complete chemical resistance
and a bubble-tight seal. The vent is designed to be easily
removed from the tank for inspection and or cleaning.
Style:
GE-DOT 3X407-AFTL
Description:
Vent to mount on a 3" ANSI,
4-Bolt Flange. Supplied with a
Teflon® liner and a valve seat.
( When ordering, please specify
pressure setting.)
MATERIALS OF CONSTRUCTION
All metallic parts Stainless Steel
"O" Ring Teflon® encapsulated silicone
Valve Seat White Teflon®
Liner White Teflon®
3" ANSI Flange, 4-Bolt
1 mr
2 r ]
,8
.I SA
B 5£ \
6
7
8' : I I I
I
ITEMS PART NUMBER DESCRIPTION
1 40219 Plug
2 402003L Rain Cover (Low Profile)
3 402004L Upper Housing (Low Profile)
4 402005 Spring
5 402006LN Low Profile Poppet with
Spring Retainer (sold with
8825010)
5A GB25010 Spring Retainer for Pressure
Only Vents (sold separately)
6 402008 Teflon® Seat
7 402007 Teflon® Silicone "O" Ring
8 402021 TL Teflon® lined Lower Housing
www.girardequip.com •Linden, NJ• Houston, TX •Chicago, IL• (800) 526-4330 • gsales@girardequip.com 15

<<<PAGE 17>>>

Style:
GE-DOT407-LAFTL
Description:
Vent to mount on a 4" ANSI,
8-Bolt Flange. Supplied with a
Teflon® liner and a valve seat.
(When ordering, please specify
pressure setting.)
MATERIALS OF CONSTRUCTION
All metallic parts Stainless Steel
"O" Ring Teflon® Encapsulated Silicone
Valve Seat White Teflon®
Liner White Teflon®
4" ANSI Flange, 8-Bolt
J l
2 ~ [ ~~
,I 5A
M " ::..
4 ( '
5 I '
6
..J I
7 I E 2 I
ITEMS PART NUMBER DESCRIPTION
1 402019 Plug
2 402003L Rain Cover (Low Profile)
3 402004L Upper Housing (Low Profile)
4 402005 Spring
5 402006LN Low Profile Poppet with
Spring Retainer (sold with
GB25010)
5A GB25010 Spring Retainer for Pressure
Only Vents (sold separately)
6 402008 Teflon® Seat
7 402007 Teflon® Silicone "O" Ring
8 402015 LPTL Teflon® Lined Lower Housing
16
www.girardequip.com •Linden, NJ• Houston, TX •Chicago, IL• (800) 526-4330 • gsales@girardequip.com

<<<PAGE 18>>>

Style:
G E- PV300-2AFTL
Description:
Vent to mount on a 2" ANSI,
4-Bolt Flange. Supplied with a
Teflon® liner and a valve seat.
(When ordering, please specify
pressure setting.)
MATERIALS OF CONSTRUCTION
All metallic parts Stainless Steel
"O" Ring Teflon® encapsulated silicone
Valve Seat White Teflon®
Liner White Teflon®
1~
2" ANSI Flange, 4-Bolt
(Shown without Rain Cover)
sl~~1
I
Teflon® liner doubles as the inlet gasket.
ITEMS PARTS NUMBER DESCRIPTION
1 202001 Bolt
2 202002PV Identification & Rating Disc
3 202003-1 Rain Cover
4 20204-1 Upper Housing
5 202005 Pressure Spring
6 202006C Upper Spring Retainer
7 202020C Solid Teflon®Valve Seat
8 202008C Teflon® Silicone "O" Ring
9 202014TL Teflon® Lined Lower Housing
www.girardequip.com •Linden, NJ• Houston, TX •Chicago, IL• (800) 526-4330 • gsales@girardequip.com 17

<<<PAGE 19>>>

GUARDIAN" 407 Vent
ENDUST
Guard your product. Guard your drivers.
Guard your business.
Bett
800.831.7160
Do what's best.

<<<PAGE 20>>>

THE BETTS GUARDIAN™ 407 VENT
A trusted guardian is proactive, always looking ahead and ready to ward off potential hazards and protect
at all times. That's the idea behind the GUARDIAN™ 407 Vent by Betts.
Model Options
Vacuum, pressure or combination
3" and 4" sizes
Flanged, threaded or swivel
25, 30, 35 psi
YOU ASKED FOR IT. WE DELIVERED.
We set out to do far more than live up to a decades-old standard 407 vent. Rather, we put our best minds
to work-to do what's best. After exhaustive research, design, engineering and manufacturing validation,
we're proud to offer the Betts GUARDIAN 407 vent-firmly placing 407 vent performance in the
21st century-meeting existing 407 requirements and even potential future ASME standards.
• Simple to maintain and service
• Meets 407 and future potential ASME standards
• Optimized efficiency for reduced chatter, wear and potential for sticking
• Modern, 21st-century design, exclusively by Betts
• Completes the DEFENDER™ Package 407 and 412-the total Betts solution
• Designed, engineered and manufactured in the USA
Call a Betts expert today! 800.831.7160
e Designed, engineered and manufactured in the USA.
Betts Industries Inc.• Warren, PA 16365 • 800.831.7160 • Bettslnd.com Do what's best.

<<<PAGE 21>>>

Betts Industries - Markings on DOT 407 Vent
Betts Industries, Inc. 407 Vent
Betts Marking for part number/model number, Set Pressure, 3 inch

<<<PAGE 22>>>

Betts Industries - Markings on DOT 407 Vent
Betts Vent- Flow Capacity 409,558@ rating pressure of 45 psig
Betts Vent-Additional manufacturing information

## Provenance

- Official: Yes
- Source: <https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2015/150096.pdf>
- Source ID: `phmsa`
- SHA-256: `86c8b39932e58f2ffb5ebb1d37fd0758dcfdadc45b0928f9a80b2849d1fae389`
- Retrieved: 2026-08-20T00:59:31.977Z
- Exported: 2026-08-21T23:37:48.464Z
- Document slug: `phmsa-interpretation-15-0096`

### Source metadata

```json
{
  "materialSubtype": "interpretation",
  "interpretationArea": "hazardous_materials",
  "representation": "full_text_from_official_pdf",
  "companies": [
    "HazMat Resources, Inc."
  ],
  "individuals": [
    "Mr. Danny Shelton"
  ],
  "refIds": [
    "15-0096"
  ],
  "catalogDates": [
    "2015-12-08"
  ],
  "catalogParts": [
    178
  ],
  "catalogRowCount": 1,
  "sourceRecordUrls": [
    "https://www.phmsa.dot.gov/node/53246"
  ],
  "linkedAttachmentUrls": [],
  "unavailableResponseUrls": [],
  "duplicateRepresentationUrls": [],
  "citedSections": [
    "178.345"
  ],
  "catalogPageUrls": [
    "https://www.phmsa.dot.gov/regulations/title49/section/178345-10"
  ],
  "pdfUrls": [
    "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2015/150096.pdf"
  ],
  "representations": [
    {
      "viewUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2015/150096.pdf",
      "detailUrl": null,
      "detailHtmlPath": null,
      "pdfUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2015/150096.pdf",
      "pdfArtifactPath": "data/sources/phmsa-interpretations/15-0096-a2a50449ae.pdf",
      "pdfArtifactSha256": "2145e7643291082bb09c07e410994f157f3bd77658566264821634d25719e258",
      "extractedTextPath": "data/sources/phmsa-interpretations/15-0096-a2a50449ae.v2.txt",
      "extractedTextSha256": "bd685100a3b3942dac397f3feabffae0035eea77f59f1ceec65751b747ee981b",
      "pageCount": 22,
      "extractionVersion": 2
    }
  ],
  "caveat": "Interpretations apply regulations to the facts presented and do not create independently enforceable requirements.",
  "jurisdiction": "US"
}
```
