# Trinity Industrials. LLC — Hazardous Materials Safety Interpretation

**Citation:** 17-0042  
**Type / status:** guidance / guidance  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective:** Not stated  
**Published:** 2017-08-14

17-0042 response to Trinity Industrials. LLC concerning 178.337.

## Document text

<<<PAGE 1>>>

Consultant
Trinity Industries, LLC
2525 Stemmons Freeway
Dallas, TX 75207
Reference No. 17-0042
Dear Mr. McRae:
This letter is in response to your April 26, 2017, letter requesting clarification of the Hazardous
Materials Regulations (HMR; 49 CFR Parts 171-180) applicable to MC 331 cargo tanks.
Specifically, you seek clarification of the requirements to provide heat treatment information on
the Department of Transportation certificate of compliance when heat treatment is not required
to be performed on an MC 331 cargo tank constructed of other than quenched and tempered
(NQT) carbon steel.
In general, the certificate of compliance does not need to contain a statement whether or not a
cargo tank was postweld heat treated. However, it is the opinion of this Office that postweld
heat treatment can be permissively indicated on the certificate of compliance if the manufacturer
chooses to disclose this information. According to § 178.337-1(f), postweld heat treatment must
be as prescribed in the American Society of Mechanical Engineers (ASME) Code except that
each cargo tank constructed in accordance with Part UHT of Section VIII of the ASME Code
must be postweld heat treated. If an MC 331 cargo tank has been postweld heat treated, this
information must be indicated on the name plate in accordance with the applicable requirements
of the ASME Code.
Please note, there are different requirements for the certificate of compliance for cargo tanks
used for anhydrous ammonia service (see § 178.337-18(a)(6)).
I hope this information is helpful. Please contact us if we can be of further assistance.
Sincerely,
the tte
Chief, Standards Development Branch
Standards and Rulemaking Division

<<<PAGE 2>>>

e-mail: infocntr@dot.gov
Standards and Rulemaking Division
Pipeline and Hazardous Material safety Administration
East Building, 2 Floor
Washington D.C. 20590-0001
Attn: PPH-10
Request for Interpretation
Reference: CFR 178.337-18 D.O.T. Certification of Compliance
Please provide clarification as to information that is to appear on a manufactures Certificate of
Compliance for MC-331 cargo tanks.
Background: MC-331 cargo tank manufactured of carbon steel, NQT material, and are not required to
be heat treated by D.O.T. regulation or ASME code.
When heat treatment is required by ASME and DOT regulations the manufactures nameplate is
stamped with the required marking and so noted on the manufactures U1-A data report.
Question: Is the manufacture required to also list functions that are not required to be performed such
as heat treatment for the cargo tank described above that is not required to be heat treated?
Please contact me if you have any questions. I may be reached via phone at 214.589.8559 or email:
greg.mcrae@trin.net
Consultant
Trinity Industries, LLC.
2525 Stemmons Freeway, Dallas, TX 75207--
-P.O. Box 75356 Dallas, TX 75356-8887

## Provenance

- Official: Yes
- Source: <https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2017/170042.pdf>
- Source ID: `phmsa`
- SHA-256: `257efd6a7192f58fa007a48cd31a0fb50f557647d3f846fced26507cf08bb482`
- Retrieved: 2026-08-20T00:59:31.977Z
- Exported: 2026-08-22T04:04:33.727Z
- Document slug: `phmsa-interpretation-17-0042`

### Source metadata

```json
{
  "materialSubtype": "interpretation",
  "interpretationArea": "hazardous_materials",
  "representation": "full_text_from_official_pdf",
  "companies": [
    "Trinity Industrials. LLC"
  ],
  "individuals": [
    "Mr. Greg McRae"
  ],
  "refIds": [
    "17-0042"
  ],
  "catalogDates": [
    "2017-08-14"
  ],
  "catalogParts": [
    178
  ],
  "catalogRowCount": 2,
  "sourceRecordUrls": [
    "https://www.phmsa.dot.gov/node/56301"
  ],
  "linkedAttachmentUrls": [],
  "unavailableResponseUrls": [],
  "duplicateRepresentationUrls": [],
  "citedSections": [
    "178.337"
  ],
  "catalogPageUrls": [
    "https://www.phmsa.dot.gov/regulations/title49/section/178337-1",
    "https://www.phmsa.dot.gov/regulations/title49/section/178337-18"
  ],
  "pdfUrls": [
    "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2017/170042.pdf"
  ],
  "representations": [
    {
      "viewUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2017/170042.pdf",
      "detailUrl": null,
      "detailHtmlPath": null,
      "pdfUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/2017/170042.pdf",
      "pdfArtifactPath": "data/sources/phmsa-interpretations/17-0042-ca7c73658b.pdf",
      "pdfArtifactSha256": "e57520569c725c78ec0f4877d79443d2c144c771da5fc84d4da839c2422e185c",
      "extractedTextPath": "data/sources/phmsa-interpretations/17-0042-ca7c73658b.v2.txt",
      "extractedTextSha256": "acd2e23a76fab5d0e75b5499a6b631fecc5338cb97b59946394e0b8151a4039e",
      "pageCount": 2,
      "extractionVersion": 2
    }
  ],
  "caveat": "Interpretations apply regulations to the facts presented and do not create independently enforceable requirements.",
  "jurisdiction": "US"
}
```