# Mark B. Hawk — Hazardous Materials Safety Interpretation

**Citation:** 20-0018  
**Type / status:** guidance / guidance  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective:** Not stated  
**Published:** 2020-05-12

20-0018 concerning 173.412, 173.415, 173.465.

## Document text

<<<PAGE 1>>>

U.S. Department
of Transportation
Pipeline and Hazardous
Materials Safety
Administration
1200 New Jersey Avenue, SE
Washington, DC 20590
May 12, 2020
Mark B. Hawk
Packaging Management Council Coordinator
8116 Villa Grande Lane
Knoxville, TN 37938
Reference No. 20-0018
Dear Mr. Hawk:
This letter is in response to your February 25, 2020, letter requesting clarification of the
Hazardous Materials Regulations (HMR; 49 CFR Parts 171-180) applicable to Type A
packaging free drop test requirements.
We have paraphrased and answered your questions as follows:
Q1. You ask whether the reference to “safety features” in § 173.465(c) is referring to the parts
of the Type A packaging that meet the performance requirements in § 173.412(j).
A1. The answer is yes. Section 173.465 details the requirements for Type A packaging tests,
and to be considered successful, the packaging must meet the requirements of
§ 173.412(j).
Q2. You ask whether the requirement in § 173.412(j)(2) that the packaging prevent “a
significant increase in radiation levels recorded or calculated at the external surfaces for
the condition before the test” means that a significant decrease in radiation levels at the
surface of the package does not need to be considered.
A2. The answer is yes. Section 173.412(j)(2) requires that the packaging will prevent “a
significant increase in radiation levels recorded or calculated at the external surfaces for
the condition before the test.” If after the free drop test in § 173.465(c) there is not a
significant increase in radiation levels at the external surface of the package, the package
is considered to have met the requirements in § 173.412(j)(2).

<<<PAGE 2>>>

Q3. You ask whether the requirement in § 173.412(j)(2) that the packaging prevent “a
significant increase in radiation levels recorded or calculated at the external surfaces for
the condition before the test” means that a significant increase or decrease in radiation
levels at 1 meter from the surface of the package does not need to be considered as a
performance standard.
A3. The answer is yes. See A2.
Q4. You ask whether the safety features of the Type A packaging need to be clearly identified
prior to performing the free drop test in § 173.465(c) and any damage to the packaging be
described on the test report after conducting the free drop test.
A4. The answer is yes, if testing a DOT Specification 7A packaging subject to § 173.465.
Section 173.415(a)(1)(i) requires documentation of testing for packagings subjected to
the physical tests of § 173.465, and if applicable, § 173.466. This documentation
includes a detailed description of each test performed and the damage to each item of the
containment system resulting from the test. For other Type A packaging, see
§§ 173.415(b)-(d) for their requirements.
Q5. You ask how it is expected to determine the worst-case drop orientation for the Type A
packaging to suffer maximum damage in § 173.465(c). You also ask if multiple drop
orientations might be needed.
A5. As noted, § 173.465(c) requires that the Type A packaging be dropped onto the target so
as to suffer maximum damage to the safety features. The Type A packaging and testing
requirements are performance oriented and this Office is not able to determine the most
appropriate orientation method for any one specific packaging configuration. There is no
restriction to conducting multiple drop orientations to determine the worst-case drop
orientation in order to meet § 173.465(c).
Q6. You ask when testing a Type A packaging containing fissile material, whether after
performing the § 173.465(c)(2) free drop test, the packaging needs to be evaluated for
any damage and then determine the orientation for maximum damage prior to performing
the free drop test in § 173.465(c)(1).

<<<PAGE 3>>>

A6. As required in § 173.465(c)(2), for packages containing fissile material, the free drop test
in § 173.465(c)(1) must be preceded by a free drop from a height of 0.3 m (1 ft.) on each
corner, or in the case of cylindrical packages, onto each of the quarters of each rim. After
this test is conducted, the free drop test in § 173.165(c)(1) must be performed and the
package must be dropped onto the target so as to suffer maximum damage to the safety
features.
I hope this information is helpful. Please contact us if we can be of further assistance.
Sincerely,
Dirk Der Kinderen
Chief, Standards Development Branch
Standards and Rulemaking Division

<<<PAGE 4>>>

Geller
January, Ikeya CTR (PHMSA)
20-0018
From:
INFOCNTR (PHMSA)
Sent:
To:
Wednesday, February 26, 2020 11:02 AM
Hazmat Interps
Subject:
FW: Request for Clarification
Attachments:
Request for Clarification - Type A Testing 2-25-2020.pdf; Mark Hawk Letter.docx
Hello Alice and Ikeya,
Attached is a request for Letter of Interpretation.
Thanks,
Jonathon, HMIC
From: Mark Hawk [mailto:hawkn14@gmail.com]
Sent: Tuesday, February 25, 2020 9:40 AM
To: INFOCNTR (PHMSA) <INFOCNTR.INFOCNTR@dot.gov>
Subject: Request for Clarification
To Whom It May Concern:
Attached is a request for clarification concerning Free Drop Testing of Type A packages.
If you have any questions, please contact me.
Best Regards,
Mark B. Hawk
Packaging Management Council Coordinator
8116 Villa Grande Lane
Knoxville, TN 37938
Phone: 865-250-3300
E-mail: hawkn14@gmail.com
1

<<<PAGE 5>>>

February 25, 2020
Standards and Rulemaking Division
Pipeline and Hazardous Materials Safety Administration (PHMSA)
U.S. Department of Transportation (DOT)
1200 New Jersey Avenue, SE
Washington, CE 20590-0001
Subject: Request for Clarification Concerning 49 CFR 173.465(c), Type A Packaging Free Drop Testing
Dear Sir/Madam:
Clarifications to the questions below are requested as to the method(s) allowed by the DOT/PHMSA for
performing free drop testing of Type A packages in accordance with 49 CFR 173.465(c) and a question as
to the result of the tests as stipulated in 173.412(j)(2).
Question 1:
Is the correct understanding of the term "safety features "in 49 CFR 173.465(c), those components of a
packaging that provide reasonable assurance they will perform their intended safety function and
prevent loss or disposal of the radioactive content and prevent an increase in radiation levels at the
external surface, as stipulated in 173.412(i)?
Question 2:
49 CFR 173.412(i) states "When evaluated against the performance requirements...the packaging will
prevent - (2) A significant increase in the radiation levels recorded or calculated at the external surface
for the condition before the test."
Is the explicit reference to a significant "increase" in radiation levels "at the external surface" intended
to imply that:
...a significant decrease at the surface need not be considered as a performance standard?
...a significant increase or decrease at 1 meter need not be considered as a performance
standard?
Either of these conditions may imply a change in the internal shielding configuration or could mean that
a post-test (or en route or post-shipment) condition would require a different Transport Index or label.
Question 3:
Prior to performing testing described in 173.465(c)(1and (c)(2), must the safety features (173.465(c)) be
clearly identified and the resulting test report describe the damage, if any, to the safety features?
Question 4:
Prior to performing testing described in 173.465(c)(1) and (c)(2), how does DOT/PHMSA expect the
tester to determine the worst-case drop orientation to suffer maximum damage to the safety features
being tested? In 49 CFR 173.465(c)(1) and (c)(2), it appears to only require one test specimen; however,
it seems as though it could take multiple test specimens and multiple drop orientations to actually
challenge the safety features in question?

<<<PAGE 6>>>

Question 5:
After performing the 1 foot free drop tests in 49 CFR 173.465(c)(2) and prior to performing the free drop
test in 49 CFR 173.465(c)(1), does the tester have to evaluate the damage from the 1 foot drop tests,
and then determine the worst case drop orientation (angle of drop, point of impact, etc.) that will cause
the maximum damage to the safety features prior to performing the 49 CFR 173.465(c)(1) free drop
Your clarification of these issues will be appreciated.
Respectfully,
Mark B. Hawk
Packaging Management Council Coordinator
8116 Villa Grande Lane,
Knoxville, TN 37938
Phone: 865-250-3300

## Provenance

- Official: Yes
- Source: <https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/docs/standards-rulemaking/hazmat/interpretations/73901/200018.pdf>
- Source ID: `phmsa`
- SHA-256: `b636254a70a23db27dd1eb2a982320198d748ec592e46b09dee31e78770ffc7a`
- Retrieved: 2026-08-20T00:59:31.977Z
- Exported: 2026-08-22T23:04:40.397Z
- Document slug: `phmsa-interpretation-20-0018`

### Source metadata

```json
{
  "materialSubtype": "interpretation",
  "interpretationArea": "hazardous_materials",
  "representation": "full_text_from_official_pdf",
  "companies": [],
  "individuals": [
    "Mark B. Hawk"
  ],
  "refIds": [
    "20-0018"
  ],
  "catalogDates": [
    "2020-05-12"
  ],
  "catalogParts": [
    173
  ],
  "catalogRowCount": 3,
  "sourceRecordUrls": [
    "https://www.phmsa.dot.gov/node/72166"
  ],
  "linkedAttachmentUrls": [],
  "unavailableResponseUrls": [],
  "duplicateRepresentationUrls": [],
  "citedSections": [
    "173.412",
    "173.412(j)",
    "173.415",
    "173.415(a)(1)(i)",
    "173.465",
    "173.465(c)",
    "173.466",
    "173.165(c)(1)"
  ],
  "catalogPageUrls": [
    "https://www.phmsa.dot.gov/regulations/title49/section/173412",
    "https://www.phmsa.dot.gov/regulations/title49/section/173415",
    "https://www.phmsa.dot.gov/regulations/title49/section/173465"
  ],
  "pdfUrls": [
    "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/docs/standards-rulemaking/hazmat/interpretations/73901/200018.pdf"
  ],
  "representations": [
    {
      "viewUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/docs/standards-rulemaking/hazmat/interpretations/73901/200018.pdf",
      "detailUrl": null,
      "detailHtmlPath": null,
      "pdfUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/docs/standards-rulemaking/hazmat/interpretations/73901/200018.pdf",
      "pdfArtifactPath": "data/sources/phmsa-interpretations/20-0018-524a7b83d0.pdf",
      "pdfArtifactSha256": "0255b73eb8b00f19388c46548945d91c4009e3766e6179ac3528381c15efa0fe",
      "extractedTextPath": "data/sources/phmsa-interpretations/20-0018-524a7b83d0.v2.txt",
      "extractedTextSha256": "53a4d1da623d87e24993afdef7163db982638ecfb891b90fe725cc65e107f549",
      "pageCount": 6,
      "extractionVersion": 2
    }
  ],
  "caveat": "Interpretations apply regulations to the facts presented and do not create independently enforceable requirements.",
  "jurisdiction": "US"
}
```