<<<PAGE 1>>>

U.S. Department
of Transportation
Pipeline and Hazardous
Materials Safety
Administration
December 10, 2020
Aris Antoniou
Gold Tank Inspection Service Inc.
P.O. Box 5638
Kingwood, TX 77325
Reference No. 20-0059
Dear Mr. Antoniou:
This is in response to your July 29, 2020, letter requesting clarification of the Hazardous
Materials Regulations (HMR; 49 CFR Parts 171-180) applicable to United Nations (UN)
portable tanks. Specifically, you describe a scenario in which an internal stop-valve on a UN
portable tank has no spring and the valve must be closed by manually turning a lever.
We have paraphrased and answered your questions as follows:
Q1. You ask whether the internal stop-valve on the bottom discharge outlet of a UN portable
tank must be self-closing or if it may be manually operated by turning a lever.
A1. Except as provided in 49 CFR § 178.275(d)(2), every bottom discharge outlet on a UN
portable tank must be equipped with three serially fitted and mutually independent shut-
off devices. The design of the equipment must include a self-closing internal stop-valve,
among other requirements. While a spring-loaded, valve is the most common type of
self-closing internal stop-valve, this design type is not specified in 49 CFR
§ 178.275(d)(3). However, any valve which closes independently without human
operation, such as turning a lever, is considered “self-closing.”
Q2. You ask whether the presence of a lining changes the applicability of the requirements in
49 CFR § 178.275(d)(3).
A2. No. The requirements for bottom discharge outlets are the same for lined and unlined
UN portable tanks.
I hope this information is helpful. Please contact us if we can be of further assistance.
Sincerely,
1200 New Jersey Avenue, SE
Washington, DC 20590
T. Glenn Foster
Chief, Regulatory Review and Reinvention Branch
Standards and Rulemaking Division

<<<PAGE 2>>>

Pollack
20-0059
29-July-2020
Associate Administrator for Hazardous Materials Safety
Pipeline and Hazardous Materials Safety Administration,
US Department of Transportation, East Building,
1200 New Jersey Avenue SE,
Washington DC 20590 - 0001
Attn: Standards and Rulemaking [PHH-10)
Subject: Request for interpretation
Dear Sir or Madam:
We request clarification (via a letter of interpretation) of a subject relating to the bottom discharge internal valve
on a UN portable tank.
49CFR178.275(d)(3) stipulates that the internal valve must be self-closing. This safety feature is normally
accomplished by having a spring-loaded valve so that, when the handle is unlatched, the spring closes the valve
rapidly. Two photographs of such a valve are below.
We have seen tanks where the internal valve has no spring and the valve must be closed by manually turning a
lever. Photographs of this arrangement are below. This arrangement has been seen on tanks with an internal
lining. We do not see where the presence of a lining changes the requirements of 49CFR178.275(d)(3).
We would like to know if this manual arrangement complies with the referenced regulation.
Sincerely,
�
/4;-
iit�niou
------------------------··
_
Gold Tank Inspection Service Inc.
PO Box 5638, Kingwood, TX 77325
e-mail: aris@goldinspection.com

<<<PAGE 3>>>

Pipelines and Hazardous Materials Safety Administratior
US Department of Transportatior
standards and Rulemaking [PHH-10
29-July-202l
Page 2 of 4
PHOTOGRAPHS of TYPICAL SPRING-LOADED INTERNAL FOOTVALVE
:

<<<PAGE 4>>>

Pipelines and Hazardous Materials Safety Administration
US Department of Transportation
Standards and Rulemaking [PHH-10]
29-July-2020
Page 3 of 4
PHOTOGRAPHS of MANUALLY OPERATED INTERNAL VALVE

<<<PAGE 5>>>

Pipelines and Hazardous Materials Safety Administration
US Department of Transportation
Standards and Rulemaking [PHH-10]
29-July-2020
Page 4 of 4
EXCERPT FROM 49CFR178.275(d)(3)
(3) Except as provided in paragraph (d)(2) of this section, every bottom discharge outlet must be equipped
with three serially fitted and mutually independent shut-off devices. The design of the equipment must
its companion flange, such that:
(i) A self-closing internal stop-valve, which is a stop-valve within the shell or within a welded flange or
(A) The control devices for the operation of the valve are designed to prevent any unintended opening
through impact or other inadvertent act;
(B) The valve is operable from above or below;
ground;
(C) If possible, the setting of the valve (open or closed) must be capable of being verified from the
(D) Except for portable tanks having a capacity less than 1,000 liters (264.2 gallons), it must be possible
to close the valve from an accessible position on the portable tank that is remote from the valve itself
within 30 seconds of actuation; and
(E) The valve must continue to be effective in the event of damage to the external device for controlling
the operation of the valve;
(ii) An external stop-valve fitted as close to the shell as reasonably practicable;
(iii) A liquid tight closure at the end of the discharge pipe, which may be a bolted blank flange or a screw
cap; and
(iv) For UN portable tanks, with bottom outlets, used for the transportation of liquid hazardous materials
hat are Class 3, PG I or II, or PG III with a flash point of less than 100 °F (38 °C); Division 5.1, PG I ol
I; or Division 6.1, PG I or II, the remote means of closure must be capable of thermal activation. The
thermal means of activation must activate at a temperature of not more than 250 °F (121 °C).

## Provenance

- Official: Yes
- Source: <https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/docs/standards-rulemaking/hazmat/interpretations/74586/200059.pdf>
- Source ID: `phmsa`
- SHA-256: `cd14f118f28cb50884bee40834f5ac6fb959cedad56fb9869494ed09d6ceb77b`
- Retrieved: 2026-08-20T00:59:31.977Z
- Exported: 2026-08-23T04:23:18.581Z
- Document slug: `phmsa-interpretation-20-0059`

### Source metadata

```json
{
  "materialSubtype": "interpretation",
  "interpretationArea": "hazardous_materials",
  "representation": "full_text_from_official_pdf",
  "companies": [
    "Gold Tank Inspection Service Inc."
  ],
  "individuals": [
    "Aris Antoniou"
  ],
  "refIds": [
    "20-0059"
  ],
  "catalogDates": [
    "2020-12-10"
  ],
  "catalogParts": [
    178
  ],
  "catalogRowCount": 1,
  "sourceRecordUrls": [
    "https://www.phmsa.dot.gov/node/72471"
  ],
  "linkedAttachmentUrls": [],
  "unavailableResponseUrls": [],
  "duplicateRepresentationUrls": [],
  "citedSections": [
    "178.275",
    "178.275(d)(2)"
  ],
  "catalogPageUrls": [
    "https://www.phmsa.dot.gov/regulations/title49/section/178275"
  ],
  "pdfUrls": [
    "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/docs/standards-rulemaking/hazmat/interpretations/74586/200059.pdf"
  ],
  "representations": [
    {
      "viewUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/docs/standards-rulemaking/hazmat/interpretations/74586/200059.pdf",
      "detailUrl": null,
      "detailHtmlPath": null,
      "pdfUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/docs/standards-rulemaking/hazmat/interpretations/74586/200059.pdf",
      "pdfArtifactPath": "data/sources/phmsa-interpretations/20-0059-c9610fc4b1.pdf",
      "pdfArtifactSha256": "e0f3e5c2b315023fc20e42057cc216c649e928c21b60b7d3cac5e21e48ff91da",
      "extractedTextPath": "data/sources/phmsa-interpretations/20-0059-c9610fc4b1.v2.txt",
      "extractedTextSha256": "a7c920427b6302a78126d8c61c2b3949dc3a3649050ffd78e33c952af81636ef",
      "pageCount": 5,
      "extractionVersion": 2
    }
  ],
  "caveat": "Interpretations apply regulations to the facts presented and do not create independently enforceable requirements.",
  "jurisdiction": "US"
}
```