# Entegris, Inc. — Hazardous Materials Safety Interpretation

**Citation:** 22-0027  
**Type / status:** guidance / guidance  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective:** Not stated  
**Published:** 2022-09-14

22-0027 response to Entegris, Inc. concerning 178.35.

## Document text

<<<PAGE 1>>>

1200 New Jersey Avenue, SE
Washington, DC 20590
U.S. Department
of Transportation
Pipeline and Hazardous
Materials Safety
Administration
September 14, 2022
Mr. James V. McManus
Senior Principal Engineer
Entegris, Inc.
7 Commerce Drive
Danbury, CT 06810
Reference No. 22-0027
Dear Mr. McManus:
This letter is in response to your March 17, 2022, letter requesting clarification of the Hazardous
Materials Regulations (HMR; 49 CFR Parts 171-180) applicable to the responsibilities of an
inspector of Department of Transportation (DOT) specification cylinders. Specifically, you seek
clarification regarding inspections of DOT-3AA cylinders performed in accordance with
§ 178.35(c) of the HMR by an Independent Inspection Agency (IIA), and whether an inspector
must verify the markings required by § 178.35(f) on 100% of the cylinders listed in the
Inspector’s report. You state that § 178.35(c) specifies that the inspector shall determine that
each cylinder made is in conformance with the applicable specification. You further state that it
is your understanding that the marking requirements in § 178.35(f) are part of the specification
for DOT-3AA cylinders. Lastly, you state that in your experience as an inspector, you visually
verify all marking requirements for 100% of all finished cylinders.
We have paraphrased and answered your questions as follows:
Q1. You ask whether an IIA’s inspector is required to verify that markings comply with
§ 178.35(f) for each finished DOT-3AA cylinder listed by serial number on the
Inspector's report.
A1. The answer is yes. In accordance with § 178.35(c), it is the duty of the inspector to
determine that each cylinder made is in conformance with the applicable specification.
Inspections shall conform to Compressed Gas Association (CGA) Pamphlet C-11,
Practices for Inspection of Compressed Gas Cylinders at Time of Manufacture.
Paragraph 5.2.12 in CGA C-11 states that “the inspector shall verify that the required
markings have been applied to finished cylinders and are in accordance with applicable
regulations.
”

<<<PAGE 2>>>

Q2. You ask whether the word “verify” means that the inspector must visually inspect each
cylinder listed on the inspector's report to ensure the markings comply with § 178.35(f) of
the HMR.
A2. The answer is no. CGA C-11 states in Section 1 that “witnessing” implies a physical
presence, whereas “verifying” usually involves gaining information without physical
presence by examining records or statements of other persons in whom trust has been
placed. Further, in paragraph 3.2.10 of CGA C-11, the word “verify” is defined as
follows: “to confirm either by examination, evidence, testimony, research, demonstration,
or comparison.”
Q3. You ask whether it is the intent of the HMR to ensure that the markings on 100% of the
cylinders are verified by the IIA’s inspector.
A3. The answer is yes.
I hope this information is helpful. Please contact us if we can be of further assistance.
Sincerely,
T. Glenn Foster
Chief, Regulatory Review and Reinvention Branch
Standards and Rulemaking Division

<<<PAGE 3>>>

Larson
From: INFOCNTR (PHMSA)
To: Hazmat Interps
Subject: FW: Request for Interpretation
Date: Wednesday, April 13, 2022 4:06:34 PM
Attachments: image001.png
image002.png
Entegris Request for Interpretation 49 CFR §178.35 (c).pdf
22-0027
Hello Hazmat Interps,
Attached is a request for interpretation.
Thanks,
Jonathon, HMIC
From: Jim McManus <Jim.McManus@entegris.com>
Sent: Friday, March 18, 2022 10:08 AM
To: INFOCNTR (PHMSA) <INFOCNTR.INFOCNTR@dot.gov>
Subject: RE: Request for Interpretation
CAUTION: This email originated from outside of the Department of Transportation (DOT). Do not click on links or open
attachments unless you recognize the sender and know the content is safe.
Hello,
I just noted the file I sent to PHMSA yesterday had an incorrect file name.
The content of the file remains the same:
The letter seeks an interpretation of 49 CFR 178.35 (c) not 180.205 (c).
Regards,
Jim
From: Jim McManus
Sent: Thursday, March 17, 2022 4:08 PM
To: infocntr@dot.gov
Subject: Request for Interpretation
Good day,
Pursuant to 49 CFR § 105.20, this letter is being submitted by e-mail to PHMSA to request an
interpretation of the Hazard Materials Regulations pertaining to the duties of an inspector who
inspects DOT specification cylinders.
Regards,
Jim

<<<PAGE 4>>>

Jim McManus
Sr. Principal Engineer
Dangerous Goods Safety Advisor (DGSA)
M 203-482-1606
T 203-207-9307
E jim.mcmanus@entegris.com
7 Commerce Drive
Danbury, CT 06810 USA
CONFIDENTIALITY NOTICE: The contents of this email message and any attachments are intended solely for the addressee(s) and
may contain confidential and/or privileged information and may be legally protected from disclosure. If you are not the intended
recipient of this message or their agent, or if this message has been addressed to you in error, please immediately alert the sender
by reply email and then delete this message and any attachments. If you are not the intended recipient, you are hereby notified that
any use, dissemination, copying, or storage of this message or its attachments is strictly prohibited.
ENTEGRIS PROPRIETARY AND CONFIDENTIAL – INTERNAL

<<<PAGE 5>>>

Specialty Gas and Engineered Materials
7 Commerce Drive
Danbury, CT 06810
800.766.2681 Toll-Free
203.794.1100 Direct
203.792.8040 Facsimile
www.entegris.com
March 17, 2022
Standards and Rulemaking Division
Pipeline and Hazardous Materials Safety Administration, Attn: PHH-10
U.S. Department of Transportation
East Building
1200 New Jersey Avenue, SE
Washington, DC 20590-0001
infocntr@dot.gov
Re: Request for Interpretation
Dear Sir or Madame:
Pursuant to 49 CFR § 105.20, this letter is being submitted by e-mail to PHMSA to request an
interpretation of the Hazard Materials Regulations pertaining to the duties of an inspector who
inspects DOT specification cylinders.
Background
This request for interpretation involves the requirements for inspections and verifications
performed by an Independent Inspection Agency who conducts these duties for DOT-3AA
cylinders in accordance with 49 CFR § 178.35 (c).
Specifically, this request for interpretation seeks to clarify if the inspector must verify the
markings required by § 178.35 (f) on 100% of the cylinders listed in the Inspector’s report.
49 CFR § 178.35 (c) states that the inspector shall determine that each cylinder made is in
conformance with the applicable specification.
The specification for DOT-3AA cylinders is codified in 49 CFR § 178.37. Interpretation of 49 CFR
§ 178.37 infers that a DOT-3AA cylinder must conform to both § 178.37 and § 178.35 − General
requirements for specification cylinders.
§ 178.35 (f) includes the marking requirements for DOT specification cylinders. The necessary
markings include the DOT specification, service pressure, serial number, symbol of
manufacturer, inspectors mark and date of test.
It follows then that the marking requirements of § 178.35 (f) are interpreted to be part of the
specification for DOT-3AA cylinders.
Additionally, § 178.35 (c)(1) states that for seamless cylinders, inspections shall conform to
section 5 of CGA C-11 (IBR, see § 171.7 of this subchapter) except as otherwise specified in the
applicable specification.
CGA C-11 section 5 states the following regarding verification of markings for seamless
cylinders:

<<<PAGE 6>>>

CGA C-11 − 5.1 Duties of certifying inspector
The certifying inspector shall ensure that the following duties are performed in accordance with
the individual DOT/TC/UN specification under which the cylinders are being manufactured:
Under bullet 11
- verify required markings, …….
My experience with inspecting and verifying markings on cylinders is as follows:
1. I visually verify that all required DOT markings are present and in the location specified
by § 178.35 (f). I do this by comparing the as marked cylinder vs. the approved
stamping layout drawing for the cylinder.
2. I visually verify the markings are stamped on the shoulder, top head, or neck.
3. I verify the markings are stamped plainly, permanently and are legible.
4. Using a suitable measurement device or gage, I verify the markings are the proper size
(0.25” or as size permits).
5. I verify any other markings are made in low stress areas other than the side wall and are
not of a size and depth that will create harmful stress concentrations. These marks may
not conflict with any DOT required markings.
6. I would do this for each finished cylinder; that is 100% inspection.
Questions:
Based on the above background information, Entegris has the following questions:
1. Does the Independent Inspection Agency’s inspector have to verify that for each
finished DOT-3AA cylinder listed by serial number on the Inspector's report, the
markings are in compliance with § 178.35 (f)?
2. Does “verify” mean that the inspector has to visually inspect each cylinder listed on the
Inspector's report to ensure the markings are in compliance? (This question assumes the
only method to verify markings would be for a human being to visually inspect the
markings).
3. Is the intent of the regulations to ensure that the markings on 100% of the cylinders are
verified by the Independent Inspection Agency’s inspector?
Entegris greatly appreciates PHMSA’s attention to this matter and looks forward to a response
that further clarifies our understanding of the hazardous materials regulations.
Should PHMSA require additional details to process this interpretation, please contact me using
the information listed below.
Sincerely,
James (Jim) V. McManus
Entegris, Inc.
Sr. Principal Engineer
M 203-482-1606
jim.mcmanus@entegris.com

## Provenance

- Official: Yes
- Source: <https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/docs/standards-rulemaking/hazmat/interpretations/76806/220027.pdf>
- Source ID: `phmsa`
- SHA-256: `7e4a41cef94e832d63e85c6fb637b450740b856e1585985b93018d22e8621a00`
- Retrieved: 2026-08-20T00:59:31.977Z
- Exported: 2026-08-22T05:52:23.791Z
- Document slug: `phmsa-interpretation-22-0027`

### Source metadata

```json
{
  "materialSubtype": "interpretation",
  "interpretationArea": "hazardous_materials",
  "representation": "full_text_from_official_pdf",
  "companies": [
    "Entegris, Inc."
  ],
  "individuals": [
    "James V. McManus"
  ],
  "refIds": [
    "22-0027"
  ],
  "catalogDates": [
    "2022-09-14"
  ],
  "catalogParts": [
    178
  ],
  "catalogRowCount": 1,
  "sourceRecordUrls": [
    "https://www.phmsa.dot.gov/node/73331"
  ],
  "linkedAttachmentUrls": [],
  "unavailableResponseUrls": [],
  "duplicateRepresentationUrls": [],
  "citedSections": [
    "178.35",
    "178.35(c)",
    "180.205",
    "178.37",
    "171.7"
  ],
  "catalogPageUrls": [
    "https://www.phmsa.dot.gov/regulations/title49/section/17835"
  ],
  "pdfUrls": [
    "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/docs/standards-rulemaking/hazmat/interpretations/76806/220027.pdf"
  ],
  "representations": [
    {
      "viewUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/docs/standards-rulemaking/hazmat/interpretations/76806/220027.pdf",
      "detailUrl": null,
      "detailHtmlPath": null,
      "pdfUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/docs/standards-rulemaking/hazmat/interpretations/76806/220027.pdf",
      "pdfArtifactPath": "data/sources/phmsa-interpretations/22-0027-eef4c19ed2.pdf",
      "pdfArtifactSha256": "bb73e6ab09ab3475cbdce068d6883ca053f6c360b9fb914a15f61020d46a78c9",
      "extractedTextPath": "data/sources/phmsa-interpretations/22-0027-eef4c19ed2.v2.txt",
      "extractedTextSha256": "9576b5e98b7485e1b9b6bc54d9e9be556bd845733a1642754252fd421037e043",
      "pageCount": 6,
      "extractionVersion": 2
    }
  ],
  "caveat": "Interpretations apply regulations to the facts presented and do not create independently enforceable requirements.",
  "jurisdiction": "US"
}
```
