# AET Environmental, Inc. — Hazardous Materials Safety Interpretation

**Citation:** 23-0019  
**Type / status:** guidance / guidance  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective:** Not stated  
**Published:** 2023-05-16

23-0019 response to AET Environmental, Inc. concerning 173.50, 173.56, 173.58.

## Document text

<<<PAGE 1>>>

U.S. Department
of Transportation
Pipeline and Hazardous
Materials Safety
Administration
May 16, 2023
1200 New Jersey Avenue, SE
Washington, DC 20590
Frank Virginia
AET Environmental, Inc.
14 Lakeside Lane
Denver, CO 80212
Reference No. 23-0019
Dear Mr. Virginia:
This letter is in response to your March 6, 2023, email requesting clarification of the Hazardous
Materials Regulations (HMR; 49 CFR Parts 171-180) applicable to waste streams containing
trace amounts of explosive hazardous material. You state that your firm manages hazardous and
non-hazardous waste for waste generators, and you are currently working with a DoD installation
in Colorado named Pueblo Chemical Depot (“the depot”). You state that the depot has
contamination of various constituents of concern1 throughout the facility where a specific area
was identified as being in contact with explosive nitro-aromatic compounds (e.g., TNT,
Dinitrotoluene, RDX, etc.). You state that these compounds have contaminated the groundwater
and you state that analysis of the post treatment groundwater samples display traces of certain
explosive compounds at approximately 0.053 µg/l. You ask questions regarding the applicability
of the Pipeline and Hazardous Materials Safety Administration (PHMSA) explosive approval
process for waste generated with trace amounts of these constituents of concern. We have
paraphrased and answered your questions as follows:
Q1. You ask whether any debris (e.g., personal protective equipment (PPE)) that may have
been exposed to waste streams containing trace amounts of explosive compounds must
have an explosives examination report submitted to PHMSA for review under the
explosive approval process.
A1. The answer is yes. Waste material that is exposed to and contaminated with explosive
compounds is considered a “new explosive.” A new explosive is an explosive produced
by a person who has not previously produced that explosive or has previously produced
that explosive but has made a change in the formulation, design, or process to alter any of
the properties of the explosive (see § 173.56). The term “formulation”
—as used in the
definition of a new explosive—applies to the entire mixture and not just the explosive
components. Any changes must be examined to determine whether the properties have
been altered and this may not be self-determined but must be determined in accordance
1 Any substance defined as a hazardous substance, hazardous waste, hazardous material, toxic substance, solid
waste, pollutant, or contaminant by an Environmental Law (https://www.lawinsider.com/dictionary/constituent-of-
concern).

<<<PAGE 2>>>

with § 173.56(b). If the explosive compounds are mixed with filters, rags, dirt, or other
material (e.g., diluted with contaminated water or other solvents), it is considered a “new
explosive” and must be approved in accordance with § 173.56(b).
However, it is the shipper’s responsibility to determine whether a specific piece of waste
material generated from the site is contaminated with explosive residue. Please note, if
further process to decontaminate or neutralize contaminated PPE before declaring it as
waste or if further sampling indicates there is no longer detectable explosive content, it
would be possible to determine the PPE is no longer an explosive hazardous material.
Q2. You believe that the contaminated water would be considered non-hazardous waste based
on the trace amount of explosive compound identified in the groundwater and you ask
whether the HMR has allowances for a de minimis quantity exception for explosive
material. You also seek confirmation that assigning a non-regulated hazardous material
description for the material is appropriate and would not warrant submission and review
in accordance with the requirements found in § 173.56(b).
A2. The answer is no. All compositions containing any amount of explosive material—
including compositions of diluted (desensitized) explosives or explosives combined or
contaminated with other materials—meet the definition of a new explosive and must be
classified and approved by PHMSA. However, this process may result in a determination
that the material is not an explosive and thus not regulated.
Please note that in accordance with § 173.56(i), if experience or other data indicate that
the hazard of a material or a device containing an explosive composition is greater or less
than indicated according to the definitions and criteria specified in §§ 173.50, 173.56, and
173.58, the Associate Administrator may specify a classification or except the material or
device from the requirements of the HMR.
I hope this information is helpful. Please contact us if we can be of further assistance.
Sincerely,
Dirk Der Kinderen
Chief, Standards Development Branch
Standards and Rulemaking Division

<<<PAGE 3>>>

Baker
23-0019
From: Raynor, T"Mia (PHMSA)
To: Hazmat Interps
Subject: FW: Interpretation of New Explosives (173.56)
Date: Tuesday, March 7, 2023 10:18:04 AM
Attachments: image001.png
SWMU 17 PPE _ Debris (002).pdf
image003.png
Hello,
Please see below.
Thanks,
T’Mia Raynor
Webmaster, Office of the PHMSA CIO
US Department of Transportation
Pipeline and Hazardous Materials Safety Administration
1200 New Jersey Ave. SE, Washington, D.C., 20590
Office: 202.366.9818 ◊ Mobile: 202.580.9447
PHMSA Home | LinkedIn | Twitter | HAZMAT | OPS
From: Virginia, Frank <frankvirginia@aetenvironmental.com>
Sent: Monday, March 6, 2023 5:36 PM
To: PHMSA Website Manager <PHMSAWebsiteManager@dot.gov>
Cc: Rosinski, Pamela A CIV USARMY USAMC (USA) <pamela.a.rosinski.civ@army.mil>; Monical, Lee B
<monical.lee@cleanharbors.com>
Subject: Interpretation of New Explosives (173.56)
CAUTION: This email originated from outside of the Department of Transportation (DOT). Do
not click on links or open attachments unless you recognize the sender and know the content
is safe.
To whom it may concern:
My firm manages hazardous and non-hazardous waste for a variety of Generators across a wide
variety of industry sectors and government agencies.
In this particular instance, I am working with a DOD instillation, Pueblo Chemical Depot, in Pueblo,
CO. The site is slated for closure in the coming years but was very instrumental in our success during
the cold war and had broad mission. Fast forward to today (70 years later) and there is wide spread
contamination of various constituents of concern (COC) throughout the facility. The Army worked
with the State of Colorado (CDPHE) to identify and establish corrective action measures for various
areas of concern throughout the site, which brings us to my question.

<<<PAGE 4>>>

Solid Waste Management Unit (SWMU 17) is an area that came in contact with explosive materials
years ago that eventually contaminated the ground water. Nitro-aromatic compounds (TNT, Dinitro-
toluene, etc), RDX, etc.) have been identified in the ground water. A Corrective Action measure,
approved by the State, calls for the ground water to be extracted, treated and reinjected back to
ground, and to take quarterly samples from monitoring wells.
Most recent analysis of the water shows traces of certain explosive compounds at 0.053 ug/l.
Excerpts from the analysis and a more detailed discussion of the history of the site and the
corrective action measures are outlined in the attached file.
The generator is trying to profile non-hazardous PPE and debris from this process. The debris may or
may not have come in direct contact with ground water containing trace levels (0.53ug/l) of
explosive compounds.
The disposal firm (Clean Harbors) is asking for an EX number demonstrating that the generator has
made a submission of this “material” (non-hazardous waste), as a “newly manufactured” explosive
for review and concurrence by PHMSA. The generator maintains that this is not necessary, as this
not a new explosive and nothing is being manufactured. This is simple a non-hazardous waste, that
has been generated during implementation of corrective action measures, that may or may not have
come in contact with water, that may have de minimus traces of explosive compounds. The
generator believes that assigning a non-regulated DOT description is appropriate and does not
believe that it requires submission and review under 173.56(b).
Could you please give us your interpretation in this matter
I would appreciate a prompt response.
Kind Regards,
Frank Virginia
AET Environmental, Inc
14 Lakeside Ln
Denver, CO 80212
(O) 303.333.8521
The information contained in this e-mail communication and any attached documentation is
intended only for the exclusive use of the designated recipient(s). If the reader or recipient of this e-
mail and any attached documentation is not the intended recipient or an employee or agent of the
intended recipient who is responsible for delivering it to the intended recipient, you are hereby
notified that any dissemination, distribution or copying of this e-mail and any attached
documentation is strictly prohibited. If you have received this e-mail in error, please immediately

<<<PAGE 5>>>

notify the sender by return e-mail and promptly delete the e-mail and any attached documentation.
This e-mail and any attached documentation may contain information that is privileged, confidential,
proprietary or otherwise protected by law. This notice serves as a confidentiality marking for the
purpose of any confidentiality or nondisclosure agreement. Receipt of this e-mail and the attached
documentation by anyone other than the intended recipient shall not be deemed a waiver of any
rights of confidentiality.

<<<PAGE 6>>>

xxxxxxxxxxxxxxxxxxxxxxx
C08213820725
PUEBLO, CO 81006
6. TECHNICAL CONTACT:
7. TITLE:
8. PHONE:
Ann Mead
719-549-4484
1. NAME OF WASTE:
B. WASTE INFORMATION
FILTERS, PPE & DEBRIS SWMU 17
2A: USEAPA WASTE CODE:
2B. DEMIL CODE:
B
E
F
G
P
2C. STATE/LOCAL/HOST-NATION WASTE CODES:
3. PROCESS GENERATING WASTE: Corrective action at a solid waste management unit under RCRA
4. PROJECTED ANNUAL VOL: 100000
5. MODE OF COLLECTION DRUM
6. IS THIS WASTE A DIOXIN LISTED WASTE AS DEFINED IN 40 CFR 261.317
] YES XINO
7. IS THIS WASTE RESTRICTED FROM LAND DISPOSAL?
(40 CFR 268)
YES
NO
HAS AN EXEMPTION BEEN GRANTED?
YES
NO
DOES THE WASTE MEET APPLICABLE TREATMENT STANDARDS ALREADY?
YES
(If yes, Enter Reference Standards in Part II, Block 6)
NO
PART II
1. MATERIAL CHARACTERIZATION
(Optional - Unless otherwise indicated)
COLOR: Varied
DENSITY:
BTU/LB:
TOTAL SOLIDS: 99 %
ASH CONTENT: 0%
LAYERING
X MULTILAYERED BILAYERED
SINGLE PHASE
(Mandatory)
PHYSICAL STATE
SOLID
LIQUID
SEMI-SOLID
GAS
OTHER
2. RCRA CHARACTERISTICS (Check all that apply)
• IGNITABLE (D001)
• CORROSIVE (D002)
REACTIVE(D003)
WATER REACTIVE
CYANIDE REACTIVE
SULFIDE REACTIVE
PH:
HIGH TOC (≥ 10%)
LOW TOC (<10%)
TREATMENT GROUP:
WASTEWATER
NON-WASTEWATER
TOXICITY CHARACTERISTIC (D004-D043)
CORRODES STEEL
DLA FORM 2511, NOV
(Formerty DRMS Form 1930)
Page 1 of 3
PDF (DLA)

<<<PAGE 7>>>

RANGE TOTAL MUST EQUAL AT LEAST 100%
3. MATERIAL COMPOSITION/UNDERLYING HAZARDOUS CONSTITUENTS
COMPONENT
CAS#
Be as descriptive as possible. Chemical names or generic descriptions, e.g. 'sludge"
CONCENTRATION
paint solids, water", etc, ara acceptable
RANGE
RANGE TOTAL MUST EQUAL AT LEAST 100%
DLA FORM 2511, NOV
(Formerly DRMS Form 1930)
Page 2 of 3
PDF (OLA)

<<<PAGE 8>>>

METHOD OF SHIPMENT
• BULK
DRUM
OTHER
DOT REPORTABLE QTY (RO)
(REF: 49 CFR 72.101, Appendix A)
EMERGENCY RESPONSE GUIDE EDITION:
EMERGENCY RESPONSE NO:
5. SPECIAL HANDLING INFORMATION
6. GENERATOR CERTIFICATION:
CHEMICAL ANALYSIS
SER KNOWLEDGE (Attach Supporting Documents
(Attach Test Results)
Explain how and why these documents comply wi
RCRA requirements)
CERTIFICATION:
1, PAMELA ROSINSKI
HEREBY CERTIFY THAT ALL INFORMATION SUBMITTED IN THIS AND ALL
ATTACHED DOCUMENTS IS TO THE BEST OF MY KNOWLEDGE AN ACCURATE REPRESENTATION OF THE
WASTE TURNED IN TO THE DLA. ALL KNOWN OR SUSPECTED HAZARDS HAVE BEEN DISCLOSED.
Pamela Rounck
03/03/2022
Signature of Generator's Representative
Date
DLA FORM 2511, NOV
(Formerly DRMS Form 1930)
Page 3 of 3
PDF (DLA)

<<<PAGE 9>>>



<<<PAGE 10>>>

Subject: Disposition of Investigation-Derived Waste
Pueblo Chemical Depot, Pueblo Colorado
Contract #: W9128F-18-D-0029
Generating Process
During the period of 14 July to 30 November 2021, TLI Solutions - Bay West Joint Venture (TLI-Bay
West JV) performed ground water sample collection activities at Solid Waste Management Unit
(SWMU) 17. Environmental sampling equipment (inoperable submersible pump, bailer filters, and
filter cartridges) and related waste (decontamination paper towels, personal protective equipment
[PPE], and sampling debris) was generated during groundwater sampling and operation and
maintenance (O&M) event. The waste was generated from Corrective Action activities conducted in
accordance with the Pueblo Chemical Depot (PCD) Resource Conservation and Recovery Act
(RCRA) Hazardous Waste Permit No. CO-13-12-23-01 (the Permit). As detailed herein, the wastes
have been characterized pursuant to 6 Code of Colorado Regulations (CCR) 1007-3, §262.11.
Site Description and RCRA Status
The Trinitrotoluene (TNT) Washout Facility and Discharge System is located in the southwestern
portion of PCD within the Western Wildlife Management Reuse Area. From the late 1940s to 1974,
TNT from various munitions was reclaimed at the TNT Washout Facility. A pump and treat system for
contaminated groundwater at SWU 17, called the Southwest Terrace (SWT) Groundwater
Extraction, Treatment, and Injection (GETI) System, was installed and operational since June 2001 to
stop offsite migration of contaminated groundwater from the SWU 17 Southwest Terrace (SWT)
area. The SWT area covers approximately five square miles extending from northwest of the TNT
Washout Facility to the western and southern boundaries of PCD. This area includes a portion of
Chico Creek. The GETI system has three distinct and separate areas of groundwater extraction,
treatment, and reinjection: Ciruli Spring, South Point, and Southwest.
Expected Waste Contaminants
SWU 17 (TNT Washout Facility and Discharge System) is the source of explosives-related
constituents in soil and groundwater in the SWT area. Explosives such as hexahydro-1,3,5-trinitro-
1,3,5-triazine (RDX), 2,4-dinitrotoluene (2,4-DNT), 2,6-dinitrotoluene (2,6-DNT), and
1,3-dinitrobenzene (1,3-DNB) are detected above the Colorado Groundwater Quality Standards
(CGWQSs) in the groundwater within the facility boundary.
The Permit identifies octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX), RDX,
1,3,5-trinitrobenzene, 1,3-DNB, tetryl, nitrobenzene, 2,4,6-TNT, 4-amino-2,6-dinitrotoluene, 2-amino-
4,6-dinitrotoluene, 2,4-DNT, 2,6-DNT, 2-nitrotoluene, 3-nitrotoluene, 4-nitrotoluene, pentaerythritol
tetranitrate (PETN), and nitrate as contaminants of concern (COCs) in groundwater. The selected
Page 1

<<<PAGE 11>>>

Accumulation Area (SAA) drum addressed in this letter.
Purged Groundwater Characterization
Table 1 presents the waste drum ID along with the associated laboratory analytical file IDs of the
groundwater sampled during the period solid waste was accumulated in drum 21PCD0232.
Groundwater samples associated with solid waste contained in this drum were analyzed for
explosives using USEPA Method SW8321B and nitrate by method USEPA SW9056A.
There were no listed waste compounds detected. However, toxicity characteristic (TC) waste
constituent 2,4-DNT, as well as a number of other site-related hazardous and non-hazardous
constituents, were detected in the purged groundwater collected during the period SAA drum
21PC0232 accumulated PPE and O&M solid waste.
None of the detected TC waste constituents exceeded the USEPA Toxicity Characteristic Regulatory
Limits (TCRLs) in the purged groundwater associated with the solid waste in the drum addressed in
this letter. Accordingly, "D" codes are not applicable to any of this waste.
TC waste constituent 2,4-DNT, as well as RDX, were detected above the CGWQS. However these
are not listed waste constituents, and therefore this waste is considered non-hazardous.
Other site-related hazardous constituents detected in the purged groundwater associated with the
solid waste in the drum addressed in this letter were below the associated CGWQSs, and therefore
have no bearing on the waste classification.
Table 1 also shows the proposed waste codes, proposed waste code justification, and the proposed
waste disposition. Table 2 provides a tabulation of the groundwater sample detections, and
compares the concentrations to the TCRLs and CGWQS.
PPE and Sampling Debris Characterization and Disposition
The PPE and sampling debris generated during this groundwater sampling event was contained
within SAA drum 21PCD0232 at the time of the sampling that was stored in the Ciruli Spring
treatment building CS 6A at SWU 17 in the GETI Area. PPE and sampling debris from sampling
events conducted between 14 July to 30 November 2021 has not been in contact with a listed waste
as characterized above, and is therefore will be disposed as non-hazardous solid waste contents will
temporarily be stored in the Building 114 covered dumpster until it is transported off-site for disposal.
This drum had an original accumulation start date (ASD) of 14 July 2021, and was filled and replaced
Page 2

<<<PAGE 12>>>

If you require additional information regarding this waste, please contact me at (571) 992-5225.
Sincerely,
Palchy
Paul Chang
TLI-Bay West JV Waste Coordinator
I concur with the waste determination as described above.
Signature
Date
Pamela Rosinski
Pueblo Chemical Depot
Enclosure
CC:
Jamal Albaiz, PCD, 45825 Highway 96 East, Building 49, Pueblo, CO 81006-9330
PCD Document Tracking/PCD Environmental Library, 45825 Highway 96 East, Building 49,
Pueblo, CO 81006-9330
T. Allen, TLI Solutions, 45825 Highway 96 East, Building 114, Pueblo, CO 81006-9330
Page 3

<<<PAGE 13>>>

She-rela
Site-rela
Site-reia
Want
Due Unrestricted Une
No
come into tontact with
groundwater with
whatle dealter
(see lab reports associated with
groundwater analysb).
Detections are listed below
2. 4-Dinitrotoluene
1,3.5-Trinitrobenzene
2-Amino-4,5-Dinitrotoluene
4-Amiso-2,6-Dinitrototuene
2.4,6-Trinitrotoluene
Nitrate (as N)
[from Documented Sold waste not tested but has
Ico to a Subtitle C or O facility, as appropriate.
Table 1: Investigation Dertred Waste Proposed Dispositie
Annust Sempling- Boundary Compliance Wolls
Puablo Chernical Depot
Characteristic
Other Constituents
Tas Are Flat/Peratit
1144361, 1144648.
1144962
PPE, baller filters.
submersible pump.
Container
She/Type
55 GL DF
2/27/2022
ASD
11/30/2021
southwest, Cirull Spring, and
the South Point Boundary
Complance Well
Colorado Department of Public Heath and Environmen
Interim Corebe Atten Groundate Remedition Sten
Colorado Groundwater Quelty Standard
Accumulation Start Date
Constituent of Concern
Drum - Are endored Plente
Mote theme Depen
sensonal protective equipment
lesource Conservation and Recovery Act
Treatmem, Storage, and Disposal Facity
Soild Waste Management Unit
Mexalondro-23,5-Trintero-1,3, 5-Telazine
Octatedro- 1.3.5,7 Tetranitro- 1,2,5.7-Tetrazocine
SWMU 17 SAA Drum Weste Despostion
dentification
Totkity Characteristk
Trichloroethylene
rolable organk compound
1P(00732
(PHE
coWas
ICAGRS

<<<PAGE 14>>>

ISLA
VIVI
Nitrate as N
0,80 M
0.50
0.090 mg/L
1
9056A
Total/NA
Client Sample ID: SPE01B
Lab Sample ID: 280-144361-3
Analyte
Result Qualifier
LOQ
DL Unit
Dil Fac D
Method
Prep Type
RDX
0.024 JM
0.095
0.020 ug/L
8321B
Total/NA
Nitrate as N
0.75 M
0.50
0.090 mg/L
9056A
Total/NA
Client Sample ID: SPE01BFD
Lab Sample ID: 280-144361-4
Analyte
Result Qualifier
LOQ
DL UnIt
Dil Fac D
Method
Prep Type
RDX
0.023
0.095
0.020 ug/l.
8321B
Total/NA
Nitrate as N
0.75
M
0.50
0.090 mg/L
9056A
Total/NA
Client Sample ID: SPE01C
Lab Sample ID: 280-144361-5
Analyte
Result Qualifier
LOQ
DL Unit
Dil Fac
D
Method
Prep Type
RDX
0.024 J M
0.095
0.020 ug/L
8321B
Total/NA
Nitrate as N
0.56
M
0.50
0.090 mg/L
9056A
Total/NA
-lient Sample ID: SPE02
Lab Sample ID: 280-144361-6
Analyte
Result Qualifier
LOQ
DL Unit
Dil Fac
Method
Prep Type
RDX
0.045 J
0.096
0.020 ug/L
8321B
Total/NA
Nitrate as N
0.64 M
0.50
0.090 mg/L
1
9056A
Total/NA
Client Sample ID: SPE02A
Lab Sample ID: 280-144361-7
Analyte
Result Qualifier
LOQ
DL Unit
Dil Fac
D
Method
Prep Type
2,4-Dinitrotoluene
0.058
J
0.076
0.018 ug/L
8321B
Total/NA
2-Amino-4,6-dinitrotoluene
0.049 J M
0.095
0.020 ug/L
8321B
Total/NA
4-Amino-2,6-dinitrotoluene
0.056 J M
0.095
0.018 ug/L
8321B
Total/NA
RDX
0.20
0.095
0.020 ug/L
1
8321B
Total/NA
Nitrate as N
0.82 M
0.50
0.090 mg/L
1
9056A
Total/NA
Client Sample ID: SPE02B
Lab Sample ID: 280-144361-8
Analyte
Result Qualifier
LOQ
DL Unit
Dil Fac D Method
Prep Type
2,4-Dinitrotoluene
0.029 J
0.076
0.018 ug/L
8321B
Total/NA
2-Amino-4,6-dinitrotoluene
0.026 JM
0.095
0.020 ug/L
8321B
Total/NA
4-Amino-2,6-dinitrotoluene
0.027 J M
0.095
0.018 ug/L
----
8321B
Total/NA
RDX
0.15
0.095
0.020 ug/L
8321B
Total/NA
Nitrate as N
0.79 M
0.50
0.090 mg/L
9056A
Total/NA
Client Sample ID: SPE03
Lab Sample ID: 280-144361-9
Analyte
Result Qualifier
LOQ
DL Unis
DIl Fac D Method
Prep Type
2,4-Dinitrotoluene
0.024 JM
0.076
0.018 ug/L
8321B
Total/NA
This Detection Summary does not include radiochemical test results.
Eurofins TestAmerica, Denver
Page 6 of 558

<<<PAGE 15>>>

Analyte
Result Qualifier
LOQ
DL Unit
Dil Fac
D
Method
Prep Type
2,4,6-Trinitrotoluene
0.039 J M
0.096
0.021 ug/L
8321B
Total/NA
2-Amino-4,6-dinitrotoluene
0.021 J M
0.096
0.020 ug/L
8321B
Total/NA
4-Amino-2,6-dinitrotoluene
0.022 J M
0.096
0.018 ug/L
8321B
Total/NA
HMX
0.018 J M
0.096
0.018 ug/L
8321B
Total/NA
RDX
0.31
0.096
0.020 ug/L
8321B
Total/NA
Nitrate as N
0.82 M
0.50
0.090 mg/L
9056A
Total/NA
Client Sample ID: SPE05
Lab Sample ID: 280-144361-11
Analyte
Result Qualifier
LOQ
DL Unit
Dil Fac
D
Method
Prep Type
RDX
0.022 JM
0.096
0.020 ug/L
8321B
Total/NA
Nitrate as N
0.84 M
0.50
0.090 mg/L
9056A
Total/NA
Client Sample ID: SPE06
Lab Sample ID: 280-144361-12
Analyte
Result Qualifier
LOQ
DL Unit
DIl Fac
D
Method
Prep Type
RDX
0.12
0.096
0.020 ug/L
8321B
Total/NA
Nitrate as N
0.75 M
0.50
0.090 mg/L
9056A
Total/NA
Client Sample ID: SPE06FD
Lab Sample ID: 280-144361-13
Analyte
Result Qualifier
LOQ
DL Unit
Dil Fac D
Method
Prep Type
RDX
0.069 J
0.095
0.020 ug/L
8321B
Total/NA
Nitrate as N
0.75 M
0.50
0.090 mg/L
9056A
Total/NA
Client Sample ID: SPE07
Lab Sample ID: 280-144361-14
Analyte
Result Qualifier
LOQ
DL Unit
Dil Fac D Method
Prep Type
2.4-Dinitrotoluene
0.049 J M
0.076
0.018 ug/L.
8321B
Tola/NA
2-Amino-4,6-dinitrotoluene
0.041 J M
0.096
0.020 ug/L
8321B
Total/NA
4-Amino-2,6-dinitrotoluene
0.045 M
0.096
0.018 ug/L
8321B
Total/NA
HMX
0.019 J
0.096
0.018 ug/L
8321B
Total/NA
RDX
0.64
0.096
0.020 ug/L
8321B
Total/NA
Nitrate as N
1.2 M
0.50
0.090 mg/L
1
9056A
Total/NA
Client Sample ID: SPE08
Lab Sample ID: 280-144361-15
Analyte
Result Qualifier
LOQ
DL Unit
Dil Fac D Method
Prep Type
Nitrate as N
1.3 M
0.50
0.090 mg/L
9056A
Total/NA
This Detection Summary does not include radiochemical test results.
Eurofins TestAmerica, Denver
Page 7 of 558

<<<PAGE 16>>>

Client Sample ID: CSE11
Lab Sample ID: 280-144648-2
Analyte
Result Qualifier
LOQ
DL Unit
Dil Fac D Method
Prep Type
1,3,5- Trinitrobenzene
0.92
0.096
0.016 ug/L
8321B
Total/NA
2,4-Dinitrotoluene
0.080 M
0.077
0.018
ug/L
8321B
Total/NA
2-Amino-4,6-dinitrotoluene
0.023 J M
0.096
0.020
ug/L
8321B
Total/NA
4-Amino-2,6-dinitrotoluene
0.048 J M
0.096
0.018 ug/L
8321B
Tota/NA
RDX
0.057 J
0.096
0.020 ug/L
8321B
Total/NA
Nitrate as N
0,44 J
0.50
0.090 mg/L
9056A
Total/NA
Client Sample ID: CSE11FD
Lab Sample ID: 280-144648-3
Analyte
Result Qualifier
LOQ
OL Unit
Dil Fac D
Method
Prep Type
2,4-Dinitrotoluene
0.085 M
0.077
0.018 ug/L
8321B
Total/NA
2-Amino-4,6-dinitrotoluene
0.037 JM
0.096
0.020 ug/L
8321B
Total/NA
4-Amino-2,6-dinitrotoluene
0.064 J M
0.096
0.018 ug/L
8321B
Total/NA
RDX
0.059 J
0.096
0.020 ug/L
1
8321B
Total/NA
1,3,5-Trinitrobenzene - DL
1.3 D
0.19
0.033 ug/L
2
8321B
Total/NA
Nitrate as N
0.44 JM
0.50
0.090 mg/L
1
9056A
Total/NA
Client Sample ID: CSE12
Lab Sample ID: 280-144648-4
Analyte
Result Qualifier
LOQ
DL Unit
Dil Fac D
Method
1
Prep Type
1,3,5-Trinitrobenzene
0.066 J
0.096
0.016 ug/L
8321B
Total/NA
RDX
0.034
JM
0.096
0.020 ug/L
1
8321B
Total/NA
Nitrate as N
0.65 M
0.50
0.090 mg/L
1
9056A
Total/NA
Client Sample ID: CSE13
Lab Sample ID: 280-144648-5
Analyte
Result Qualifier
LOQ
DL Unit
Dil Fac
D
Method
8321B
Total/NA
Prep Type
1,3,5-Trinitrobenzene
0.13
0.096
0.016 ug/L
RDX
0.065 J
0.096
0.020 ug/L
8321B
Total/NA
Nitrate as N
0.61 M
0.50
0.090 mg/L
1
9056A
Total/NA
Client Sample ID: CSE14
Lab Sample ID: 280-144648-6
Analyte
Result Qualifier
LoQ
DL Unit
Prep Type
1,3,5-Trinitrobenzene
0.13
0.095
0.016 ug/L
8321B
Total/NA
RDX
0.038 J
0.095
0.020 ug/L
8321B
Total/NA
Nitrate as N
0,48 J M
0.50
0.090 mg/L
9056A
Total/NA
Client Sample ID: CSE15
Lab Sample ID: 280-144648-7
Analyte
Result Qualifier
LOQ
DL Unit
Dil Fac D Method
8321B
Prep Type
1,3,5- Trinitrobenzene
0.58
0.095
0.016 ug/L
Total/NA
2.4-Dinitrotoluene
0.053 J
0.076
0.018 ug/L
--
8321B
Total/NA
4-Amino-2,6-dinitrotoluene
0.023 JM
0.095
0.018 ug/L
8321B
Total/NA
This Detection Summary does not include radiochemical test results.
Eurofins TestAmerica, Denver
Page 7 of 786

<<<PAGE 17>>>

2,4-Dinitrotoluene
0.072 J
0.077
0.018 ug/L
8321B
Total/NA
RDX
0.047 J
0.096
0.020 ug/L
8321B
Tota/NA
Nitrate as N
0.44 J M
0.50
0.090 mg/L
1
9056A
Total/NA
Client Sample ID: CSE17
Lab Sample ID: 280-144648-9
Analyte
Result Qualifier
LOQ
DL Unit
Dil Fac
D
| Method
Prep Type
2.4-Dinitrotoluene
0.11
0.076
0.018 ug/L
8321B
Total/NA
4-Amino-2,6-dinitrotoluene
0.028 JM
0.095
0.018 ug/L
1
8321฿
Total/NA
RDX
0.088 J
0.095
0.020 ug/L
8321B
Total/NA
1,3,5-Trinitrobenzene - DL
2.0
D
0.19
0.032 ug/L
2
8321B
Total/NA
Nitrate as N
0.42 JM
0.50
0.090 mg/L
1
9056A
Total/NA
Client Sample ID: CSE18
Lab Sample ID: 280-144648-10
Analyte
Result Qualifier
LOQ
DL Unit
Dil Fac D Method
Prep Type
2,4-Dinitrotoluene
0.11
0.078
0.019 ug/L
1
8321B
Total/NA
2-Amino-4,6-dinitrotoluene
0.023
J M J1
0.098
0.021 ug/L
8321B
Total/NA
4-Amino-2,6-dinitrotoluene
0.037 JM J1
0.09B
0.019 ug/L
8321B
Total/NA
RDX
0.13
0.098
0.021 ug/L
8321B
Total/NA
1,3,5-Trinitrobenzene - DL
2.6 D
0.39
0.067 ug/L
8321B
Total/NA
Nitrate as N
0.48 J M
0.50
0.090 mg/L
9056A
Total/NA
Client Sample ID: CSE19
Lab Sample ID: 280-144648-11
Analyte
Result Qualifier
LOQ
DL Unit
Dil Fac D Method
Prep Type
2,4-Dinitrotoluene
0.065 J
0.077
0.018 ug/L
8321B
Total/NA
4-Amino-2,6-dinitrotoluene
0.027 J M
0.096
0.018 ug/L
8321B
Total/NA
RDX
0.070 J
0.096
0.020 ug/L
8321B
Total/NA
1,3,5-Trinitrobenzene - DL
2.8 D
0.19
0.033 ug/L
8321B
Total/NA
Nitrate as N
0.50 M
0.50
0.090 mg/L
9056A
Total/NA
Client Sample ID: CSE20
Lab Sample ID: 280-144648-12
Analyte
Result Qualifier
LOa
DL Unit
Dil Fac D Method
Prep Type
1,3,5-Trinitrobenzene
0.34
0.096
0.016 ug/L
- 8321B
Total/NA
2,4-Dinitrotoluene
0.037 J
0.077
0.018 ug/L
8321B
Total/NA
2-Amino-4,6-dinitrotoluene
0.020 JM
0.096
0.020 ug/L
8321B
Tota/NA
4-Amino-2,6-dinitrotoluene
0.028 JM
0.096
0.018 ug/L
8321B
Tota/NA
RDX
0.058 J
0.096
0.020 ug/L
8321B
Total/NA
Nitrate as N
0.70 M
0.50
0.090 mg/L
9056A
Total/NA
Client Sample ID: CSE22
Lab Sample ID: 280-144648-13
Analyte
Result Qualifier
LOQ
DL Unit
Dil Fac D Method
Prep Type
2,4-Dinitrotoluene
0.24
0.077
8321B
Total/NA
2-Amino-4,6-dinitrotoluene
0.062 J M
0.096
0.020 ug/L
1
8321B
Total/NA
This Detection Summary does not include radiochemical test results
Eurofins TestAmerica, Denver
Page 8 of 786

<<<PAGE 18>>>

ulent sample lo. cockerb
Lab sample IN. c00-144040-14
Analyte
Result Qualifier
LOQ
DL Unit
DIl Fac D
Method
Prep Type
2,4-Dinitrotoluene
0.21
0.077
0.018 ug/L
8321B
Total/NA
2-Amino-4,6-dinitrotoluene
0.053 JM
0.096
0.020 ug/L
8321B
Total/NA
4-Amino-2,6-dinitrotoluene
0.071 JM
0.096
0.018 ug/L
8321B
Total/NA
HMX
0.031 J M
0.096
0.018 ug/L
8321B
Total/NA
RDX
0.33
0.096
0.020 ug/L
8321B
Total/NA
1,3,5-Trinitrobenzene - DL
1.6 D
0.19
0.033 ug/L
8321B
Total/NA
Nitrate as N
0.49 J M
0.50
0.090 mg/L
9056A
Total/NA
Client Sample ID: CSE23
Lab Sample ID: 280-144648-15
Analyte
Result Qualifier
LOQ
-DL Unit
Dil Fac D
Method
Prep Type
1,3,5-Trinitrobenzene
0.30
0.096
0.016 ug/L
8321B
Total/NA
2,4-Dinitrotoluene
00054 J
0.077
0.018 ug/L
8321B
Total/NA
2-Amino-4,6-dinitrotoluene
0.022 J M
0.096
0.020 ug/L
8321B
Total/NA
4-Amino-2.6-dinitrotoluene
0.029 J M
0.096
0.018 ug/L
8321B
Total/NA
RDX
0.074 J
0.096
0.020 ug/L
8321B
Total/NA
Nitrate as N
0.31 J M
0.50
0.090 mg/L
9056A
Total/NA
Client Sample ID: CSE24
Lab Sample ID: 280-144648-16
Analyte
Result Qualifier
LOQ
DL Unit
Dil Fac D
Method
Prep Type
1,3,5-Trinitrobenzene
0.40
0.096
0.016 ug/L
8321B
Tota/NA
2,4-Dinitrotoluene
0.091 M
0.076
0.018 ug/L
8321B
Total/NA
2-Amino-4,6-dinitrotoluene
0.039 J M
0.096
0.020 ug/L
1
8321B
Total/NA
4-Amino-2,6-dinitrotoluene
0.049 J M
0.096
0.018 ug/L
8321B
Total/NA
HMX
0.018 J M
0.096
0.018 ug/L
1
8321B
Total/NA
RDX
0.16
0.096
0.020 ug/L
1
8321B
Total/NA
Nitrate as N
0.40 J M
0.50
0.090 mg/L
9056A
Total/NA
Client Sample ID: CSE30
Lab Sample ID: 280-144648-17
Analyte
Result Qualifier
LOQ
DL Unit
DIl Fac D Method
Prep Type
1,3.5-Trinitrobenzene
1.0
0.095
0.016 ug/L
8321B
Total/NA
2,4-Dinitrotoluene
0.076
0.076
0.018 ug/L
1
8321B
Tota/NA
2-Amino-4.6-dinitrotoluene
0.026 JM
0.095
0.020 ug/L
1
8321B
Total/NA
4-Amino-2,6-dinitrotoluene
0.059 J M
0.095
0.018 ug/L
1
8321B
Total/NA
RDX
0.065 J
0.095
0.020 ug/L
1
8321B
Total/NA
Nitrate as N
0.46 JM
0.50
0.090 mg/L
9056A
Total/NA
Client Sample ID: CSE31
Lab Sample ID: 280-144648-18
Analyte
Result Qualifier
LOQ
DL Unit
DIl Fac D Method
Prep Type
1.3,5- Trinitrobenzene
1.2
0.095
0.016 ug/L
8321B
Total/NA
2,4-Dinitrotoluene
0,088
0.076
0,018 ug/L
1
8321B
Total/NA
This Detection Summary does not include radiochemical test results.
Eurofins TestAmerica, Denver
Page 9 of 786

<<<PAGE 19>>>

Analyte
Result Qualifier
LOQ
DL Unit
Dil Fac D Method
Prep Type
1,3,5-Trinitrobenzene
0.054
J
0.095
0.016 ug/L
8321B
Total/NA
Nitrate as N
0.43 J M
0.50
0.090 mg/L
9056A
Total/NA
Client Sample ID: CSE45
Lab Sample ID: 280-144648-20
Analyte
Result Qualifier
LOQ
DL Unit
DIl Fac D Method
Prep Type
1,3,5-Trinitrobenzene
0.57
0.096
0.016 ug/L
8321B
Total/NA
2,4-Dinitrotoluene
0.023 J
0.077
0.018 ug/L
1
8321B
Total/NA
RDX
0.027 J
0.096
0.020 ug/L
8321B
Total/NA
Nitrate as N
0.49 J M
0.50
0.090 mg/L
1
9056A
Tota/NA
Client Sample ID: CSE46
Lab Sample ID: 280-144648-21
Analyte
Result Qualifier
LOQ
DL Unit
Dil Fac D Method
Prep Type
1,3,5-Trinitrobenzene
0.048
J
0.094
0.016 ug/L
8321B
Total/NA
RDX
0.025 J
0.094
0.020 ug/L
8321B
Total/NA
Nitrate as N
0.47 J
0,50
0.090 mg/L
1
9056A
Total/NA
This Detection Summary does not include radiochemical test results.
Eurofins TestAmerica, Denver
Page 10 of 786

<<<PAGE 20>>>

Client Sample ID: SWE02
Lab Sample ID: 280-144962-4
No Detections.
Client Sample ID: SWE03
Lab Sample ID: 280-144962-5
No Detections.
Client Sample ID: SWE04
Lab Sample ID: 280-144962-6
Analyte
Result Qualifier
LOQ
DL UnIt
Dil Fac
D
Method
Prep Type
2,4-Dinitrotoluene
0.030
J
0.076
0.018 ug/L
8321B
Total/NA
2-Amino-4,6-dinitrotoluene
0.020
JM
0.095
0.020 ug/L
8321B
Total/NA
4-Amino-2,6-dinitrotoluene
0.038
JM
0.095
0.018
ug/L
8321B
Total/NA
RDX
0.11
0,095
0.020 ug/L
1
8321B
Total/NA
Client Sample ID: SWE05
Lab Sample ID: 280-144962-7
Analyte
Result Qualifier
LOQ
DL Unit
Dil Fac D Method
Prep Type
2,4-Dinitrotoluene
0.027
J
0.077
0.018 ug/L
8321B
Total/NA
2-Amino-4,6-dinitrotoluene
0.020
0.096
0.020 ug/L
8321B
Total/NA
4-Amino-2,6-dinitrotoluene
0.054
J
0.096
0.018 ug/L
8321B
Total/NA
RDX
0.18
0.096
0,020 ug/L
8321B
Total/NA
Client Sample ID: SWE06
Lab Sample ID: 280-144962-8
Analyte
Result Qualifier
Loa
DL Unit
DIl Fac D Method
Prep Type
2,4-Dinitrotoluene
0.17
0.077
0.018 ug/L
8321B
Total/NA
2-Amino-4,6-dinitrotoluene
0.060 J
0.096
0.020 ug/L
8321B
Total/NA
4-Amino-2,6-dinitrotoluene
0.11
0.096
0.018 ug/L
1
8321B
Total/NA
RDX
0.65
0.096
0.020 ug/L
1
8321B
Total/NA
Client Sample ID: SWE30
Lab Sample ID: 280-144962-9
Analyte
Result Qualifier
LoQ
DL Unit
Dil Fac D Method
Prep Type
2, 4-Dinitrotoluene
0.13
0.077
0.018wg/L
1
8321B
Total/NA
2-Amino-4, 6-dinitrotoluene
0.032 J
0.096
0.020 ug/L
8321B
Total/NA
4-Amino-2, 6-dinitrotoluene
0.11
0.096
0.018 ug/L
8321B
Total/NA
RDX
0.89
0.096
0.020 ug/L
8321B
Total/NA
Nitrate as N
5.8
0.50
0.090 mg/L
1
9056A
Total/NA
Client Sample ID: SWE31
Lab Sample ID: 280-144962-10
Analyte
Result Qualifier
LOQ
DL Unit
Dil Fac D Method
Nitrate as N
4.9
0.50
Prep Type
0.090 mg/L
9056A
Total/NA
This Detection Summary does not include radiochemical test results.
Eurofins TestAmerica, Denver
Page 6 of 537

<<<PAGE 21>>>

4-Amino-2,6-dinitrotoluene
0.070 J
0.096
0.018 ug/L
8321B
Total/NA
RDX
1.2
0.096
0.020 ug/L
1
8321B
Total/NA
Nitrate as N
3.3
0.50
0.090 mg/L
1
9056A
Tota/NA
Client Sample ID: SWE33
Lab Sample ID: 280-144962-13
Analyte
Result Qualifler
LOQ
DL Unit
Dil Fac D Method
Prep Type
2-Amino-4,6-dinitrotoluene
0.46
0.095
0.020 ug/L
8321B
Total/NA
4-Amino-2,6-dinitrotoluene
- 0.73
0.095
0.018 ug/L
8321B
Total/NA
HMX
0.080 J
0.095
0.018 ug/L
8321B
Total/NA
2,4-Dinitrotoluene - DL
1.5 D
0.38
0.091 ug/L
8321B
Total/NA
RDX - DL
2.5 J1D
0.48
0.10 ug/L
8321B
Total/NA
Nitrate as N
5.7
0.50
0.090 mg/L
1
9056A
Total/NA
Client Sample ID: SWE34
Lab Sample ID: 280-144962-14
Analyte
Result Qualifier
LOO
DL Unit
Dil Fac D Method
Prep Type
2,4-Dinitrotoluene
0.66
0.077
0.018 ug/L
1
8321B
Total/NA
2-Amino-4,6-dinitrotoluene
0.20
0.096
0.020 ug/L
1
8321B
Tota/NA
4-Amino-2,6-dinitrotoluene
0.41
0.096
0.018 ug/L
1
8321B
Total/NA
RDX - DL
3.3 D
1.9
0.40 ug/L
20
8321B
Total/NA
Nitrate as N
4.0
0.50
0.090 mg/L
1
9056A
Total/NA
This Detection Summary does not include radiochemical test results.
Eurofins TestAmerica, Denver
Page 7 of 537

<<<PAGE 22>>>

Organization:
Building:
Hazardous Waste Manger and Alternate Manager
SWMU17-(GETI) TNT WO
Ann Mead
DATE
AMOUNT
TYPE OF WASTE
NAME (Print Clearly)
7-14-21
12 Co. FT.
PAPER TUWEIS
TONY AlIEN
7-20-21
• 25 cufT
TONY AllE
1/2621
1.25 cuff
sloves, fiters, filter wrappers
Veil Nelsor
/ Bag PIE
7-29•21
As Bell tals sut sampling
Bill/LEMP
8-23.21
11" land
Dead submersible
Neil Nelson
10-20-21
1.29 cuft
y'aues. Filtrs,
Tony AllEN
11-17•21
" " each
submersible pumps, gloves
Neil Nelson
TURN-IN VERIFICATION
GENERATOR CERTIFICATION
1.
, hereby certify that all the information submitted in this document is to the best of my knowledge an
accurate representation of the waste turned in or burned. All known or suspected hazards have been disclosed. If a waste profile exists
on this waste, I certify that no changes have occurred in the process that generated this waste.
SIGNATURE
Date:
DISPOSAL METHOD: (Circle One: BLEND FOR ENERGY RECOVERY, RECYCLED, SENT TO HWC)
This section to be filled in by Hazardous Waste Center Personnel
Profile Number:
Document Number:
Tum-in date

<<<PAGE 23>>>

## Provenance

- Official: Yes
- Source: <https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/docs/standards-rulemaking/hazmat/interpretations/77591/230019.pdf>
- Source ID: `phmsa`
- SHA-256: `ce3eed9de998d0e1836a7cf62f507f9d17d44a9003682ef62ac5ab6c84ae2575`
- Retrieved: 2026-08-20T00:59:31.977Z
- Exported: 2026-08-24T19:39:44.800Z
- Document slug: `phmsa-interpretation-23-0019`

### Source metadata

```json
{
  "materialSubtype": "interpretation",
  "interpretationArea": "hazardous_materials",
  "representation": "full_text_from_official_pdf",
  "companies": [
    "AET Environmental, Inc."
  ],
  "individuals": [
    "Frank Virginia"
  ],
  "refIds": [
    "23-0019"
  ],
  "catalogDates": [
    "2023-05-16"
  ],
  "catalogParts": [
    173
  ],
  "catalogRowCount": 3,
  "sourceRecordUrls": [
    "https://www.phmsa.dot.gov/node/73701"
  ],
  "linkedAttachmentUrls": [],
  "unavailableResponseUrls": [],
  "duplicateRepresentationUrls": [],
  "citedSections": [
    "173.50",
    "173.56",
    "173.58"
  ],
  "catalogPageUrls": [
    "https://www.phmsa.dot.gov/regulations/title49/section/17350",
    "https://www.phmsa.dot.gov/regulations/title49/section/17356",
    "https://www.phmsa.dot.gov/regulations/title49/section/17358"
  ],
  "pdfUrls": [
    "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/docs/standards-rulemaking/hazmat/interpretations/77591/230019.pdf"
  ],
  "representations": [
    {
      "viewUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/docs/standards-rulemaking/hazmat/interpretations/77591/230019.pdf",
      "detailUrl": null,
      "detailHtmlPath": null,
      "pdfUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/docs/standards-rulemaking/hazmat/interpretations/77591/230019.pdf",
      "pdfArtifactPath": "data/sources/phmsa-interpretations/23-0019-0a9c5fc427.pdf",
      "pdfArtifactSha256": "fec3d35b1f7277faba003078154e11f651beda9c3be0d247cfec76a1abe95cbb",
      "extractedTextPath": "data/sources/phmsa-interpretations/23-0019-0a9c5fc427.v2.txt",
      "extractedTextSha256": "cb99c64d387f1adec664d11326a5ef6de702fa135685efd65b31d755131702a5",
      "pageCount": 23,
      "extractionVersion": 2
    }
  ],
  "caveat": "Interpretations apply regulations to the facts presented and do not create independently enforceable requirements.",
  "jurisdiction": "US"
}
```
