23-0092 response to Encore Container concerning 178.603, 178.810.

## Document text

<<<PAGE 1>>>

1200 New Jersey Avenue, SE
Washington, DC 20590
U.S. Department
of Transportation
Pipeline and Hazardous
Materials Safety
Administration
March 21, 2024
Mr. Chas Key
Encore Container
7021 Augusta Road
Greenville, SC 29605
Reference No. 23-0092
Dear Mr. Key:
This letter is in response to your July 28, 2023, email requesting clarification of the Hazardous
Materials Regulations (HMR; 49 CFR Parts 171-180) applicable to the testing of a UN31HA1
composite intermediate bulk container (IBC) intended to contain liquids. Specifically, you ask
whether the HMR require that a composite IBC be vented so that the internal and external
pressures reach equilibrium after concluding a drop test performed in accordance with § 178.810.
The answer is no. As noted in your email, the HMR—as provided in § 178.603(f)(1)—states that
a non-bulk packaging containing liquids is considered to successfully pass the drop test for each
sample tested if each packaging does not leak when equilibrium has been reached between the
internal and external pressures, except for inner packagings of combination packagings when it is
not necessary that the pressures be equalized. However, for composite IBCs intended to contain
liquids, the IBC must be filled to not less than 98 percent of their maximum capacity, and the
pressure relief devices must be removed and their apertures plugged or rendered inoperative. See
§ 178.810(b)(1). Furthermore, for all IBC design types—including composite IBCs—the criteria
for passing the drop test means: (1) there may be no damage which renders the IBC unsafe to be
transported for salvage or for disposal, and no loss of contents; (2) the IBC shall be capable of
being lifted by an appropriate means until clear of the floor for five minutes; and (3) a slight
discharge from a closure upon impact is not considered to be a failure of the IBC provided that no
further leakage occurs. See § 178.810(e). As such, there is no specific requirement to vent a
composite IBC after concluding a drop test so that the internal and external pressures reach
equilibrium. While it is not a requirement, allowing an IBC to reach pressure equilibrium is
permissible.
I hope this information is helpful. Please contact us if we can be of further assistance.
Sincerely,
Steven Andrews
Acting Chief, Regulatory Review and Reinvention Branch
Standards and Rulemaking Division

<<<PAGE 2>>>

Wolcott
23-0092
From: INFOCNTR (PHMSA)
To: Dodd, Alice (PHMSA)
Cc: Hazmat Interps
Subject: FW: Interpretation Request of 49 CFR 178.810 for Encore of Greenville, LLC dba Encore Container (M6076)
Date: Friday, July 28, 2023 10:59:02 AM
Hi Alice,
Please see the below interpretation request.
Let us know if you need anything else.
Regards,
-Breanna
From: Chas Key <Chas.Key@encorecontainer.com>
Sent: Friday, July 28, 2023 10:02 AM
To: INFOCNTR (PHMSA) <INFOCNTR.INFOCNTR@dot.gov>
Subject: RE: Interpretation Request of 49 CFR 178.810 for Encore of Greenville, LLC dba Encore
Container (M6076)
CAUTION: This email originated from outside of the Department of Transportation (DOT). Do
not click on links or open attachments unless you recognize the sender and know the content
is safe.
My contact information is:
Chas Key
Chief Compliance Officer
Encore of Greenville, LLC dba Encore Container (M6076)
7021 Augusta Rd
Greenville, SC 29605
864-884-3196
From: INFOCNTR (PHMSA) <INFOCNTR.INFOCNTR@dot.gov>
Sent: Friday, July 28, 2023 9:52 AM
To: Chas Key <Chas.Key@encorecontainer.com>
Subject: Automatic reply: Interpretation Request of 49 CFR 178.810 for Encore of Greenville, LLC
dba Encore Container (M6076)
Thank you for contacting the HAZMAT Info Center (HMIC) within the Pipeline and Hazardous
Materials Safety Administration (PHMSA). The HMIC assists with the use of the Hazardous Materials
Regulations (HMR), and provides other services as noted on our website (click here). The
information center is staffed Monday through Friday, 9am-5pm EST. This email acknowledges
receipt of your inquiry.

<<<PAGE 3>>>

To better assist you, we ask that you provide your name, a phone number, and a detailed question
or concern. You may respond to this email or contact the HMIC by phone at +1 (800) 467-4922 or +1
(202) 366-4488.
Regards,
HazMat InfoCenter Team

## Provenance

- Official: Yes
- Source: <https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/2024-03/230092.pdf>
- Source ID: `phmsa`
- SHA-256: `6a7d3b6422be6f3455a8d32f5567021171d3c964d943c0b2af1eeb5506beed86`
- Retrieved: 2026-08-20T00:59:31.977Z
- Exported: 2026-08-22T18:50:09.602Z
- Document slug: `phmsa-interpretation-23-0092`

### Source metadata

```json
{
  "materialSubtype": "interpretation",
  "interpretationArea": "hazardous_materials",
  "representation": "full_text_from_official_pdf",
  "companies": [
    "Encore Container"
  ],
  "individuals": [
    "Chas Key"
  ],
  "refIds": [
    "23-0092"
  ],
  "catalogDates": [
    "2024-03-21"
  ],
  "catalogParts": [
    178
  ],
  "catalogRowCount": 2,
  "sourceRecordUrls": [
    "https://www.phmsa.dot.gov/node/74096"
  ],
  "linkedAttachmentUrls": [],
  "unavailableResponseUrls": [],
  "duplicateRepresentationUrls": [],
  "citedSections": [
    "178.603",
    "178.603(f)(1)",
    "178.810"
  ],
  "catalogPageUrls": [
    "https://www.phmsa.dot.gov/regulations/title49/section/178603",
    "https://www.phmsa.dot.gov/regulations/title49/section/178810"
  ],
  "pdfUrls": [
    "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/2024-03/230092.pdf"
  ],
  "representations": [
    {
      "viewUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/2024-03/230092.pdf",
      "detailUrl": null,
      "detailHtmlPath": null,
      "pdfUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/2024-03/230092.pdf",
      "pdfArtifactPath": "data/sources/phmsa-interpretations/23-0092-ccf0c2363c.pdf",
      "pdfArtifactSha256": "a1b7d50a282742eea7415aa487c962ae27022a42a400e35e5de66c50668a549b",
      "extractedTextPath": "data/sources/phmsa-interpretations/23-0092-ccf0c2363c.v2.txt",
      "extractedTextSha256": "0f0b3808e5626ab383297a2e06bdb9f812b4a5a01a396b1f5e37dfd3c2f90fb8",
      "pageCount": 3,
      "extractionVersion": 2
    }
  ],
  "caveat": "Interpretations apply regulations to the facts presented and do not create independently enforceable requirements.",
  "jurisdiction": "US"
}
```