# Usher Transport Inc. — Hazardous Materials Safety Interpretation

**Citation:** 24-0043  
**Type / status:** guidance / guidance  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective:** Not stated  
**Published:** 2024-08-22

24-0043 response to Usher Transport Inc. concerning 172.328.

## Document text

<<<PAGE 1>>>

U.S. Department
of Transportation
Pipeline and Hazardous
Materials Safety
Administration
1200 New Jersey Avenue, SE
Washington, DC 20590
August 22, 2024
Jed Hudson
Safety Manager
Usher Transport Inc.
3801 Shanks Lane
Louisville, KY 40216
Reference No. 24-0043
Dear Mr. Hudson:
This letter is in response to your May 29, 2024, email requesting clarification of the Hazardous
Materials Regulations (HMR; 49 CFR Parts 171-180) applicable to the “emergency shutoff”
marking on cargo tanks. You provided photographs of a cargo tank motor vehicle (CTMV) that
has two markings in separate locations. The primary marking is located directly beside the
manually-activated remote shutoff device on the rear-end tank protection device, but the marking
is damaged. The secondary marking is located on the right rear side of the cargo tank, pointing
vertically downward in a manner you believe is in an area immediately adjacent to the manually-
activated remote shutoff device. You also note a previous letter of interpretation
(Reference No. 17-0029), which you believe represents your current situation regarding the
placement of the secondary “emergency shutoff” marking on the cargo tank. Acknowledging that
the primary marking is weathered and damaged such that it does not satisfy the marking
requirement, you ask whether the secondary marking satisfies the requirement of § 172.328(d) to
have an “emergency shutoff” marking “located in an area immediately adjacent to the means of
closure.”
The HMR do not define the term “adjacent,” but a common dictionary definition of the term
“adjacent” means to be nearby or immediately preceding or following. Based on the photographs
you provided, it is the opinion of this Office that the secondary “emergency shutoff” marking
located on the right rear side of the cargo tank does not meet the intent of § 172.328(d) because
the marking is not in “an area immediately adjacent (emphasis added) to the means of closure.”
Moreover, the secondary marking has an arrow pointing vertically downward towards a section
of the CTMV on the back side of the framing on which the rear placard is displayed that does

<<<PAGE 2>>>

not accurately point towards the means of closure of the shutoff device, which is located at the
rear of the CTMV below the placard. Please note that the position where the damaged primary
marking is located would meet the intent of § 172.328(d).
I hope this information is helpful. Please contact us if we can be of further assistance.
Sincerely,
Dirk Der Kinderen
Chief, Standards Development Branch
Standards and Rulemaking Division

<<<PAGE 3>>>

Vore
24-0043
Jones, Jessie Jane CTR (PHMSA)
From: INFOCNTR (PHMSA)
Sent: Friday, June 7, 2024 1:41 PM
To: Dodd, Alice (PHMSA)
Cc: Hazmat Interps
Subject: FW: Letter for Interpretation
Attachments: 170029 (2).pdf; PHMSA Letter Emegerency Shut-Off Marking.pdf
Follow Up Flag: Follow up
Flag Status: Flagged
Hi Alice,
Please see the a ached interpreta on request.
Let us know if you need anything.
Regards,
-Breanna
From: Jed Hudson <jhudson@ushertransport.com>
Sent: Wednesday, May 29, 2024 1:24 PM
To: PHMSA HM InfoCenter <PHMSAHMInfoCenter@dot.gov>
Subject: Letter for Interpretation
CAUTION: This email originated from outside of the Department of Transportation (DOT). Do not click on links
or open attachments unless you recognize the sender and know the content is safe.
To Whom It May Concern,
Please see attached letters and photos for interpretation.
Respectfully,
Jed Hudson
Safety Manager | Safety & Risk Management | CDS
T: (502)449-4000
M: (859)661-2034
jhudson@ushertransport.com - www.ushertransport.com
3801 Shanks Lane, Louisville, KY 40216 USA
"In valor there is hope." - Publius Cornelius Tacitus
1

<<<PAGE 4>>>



<<<PAGE 5>>>

Safety Manager
Thatcher Transportation, Inc.
1905 Fortune Road
Salt Lake City, UT 84104
Reference No. 17-0029
Dear Mr. Olsen:
This letter is in response to your March 21, 2017, email requesting clarification of the Hazardous
Materials Regulations (HMR; 49 CFR Parts 171-180) applicable to the emergency shutoff
marking on cargo tanks. You note that § 172.328(d) specifies the emergency shutoff marking
must be immediately adjacent to the emergency closure device. You state that you received a
violation for the emergency shutoff marking not being close enough to the emergency closure
device and include in your email a photo showing the marking approximately 4 inches right of
and 12 inches above the device. Specifically, you ask how close the emergency shutoff marking
must be to the emergency closure device in order to meet the requirements of § 172.328(d).
Section 172.328(d) does not specify the distance the emergency shutoff marking must be in order
to be immediately adjacent to the emergency closure device. However, based on the description
you provided in your email and the attached photo, it is the opinion of this Office that the
emergency shutoff marking, as pictured, would be considered adjacent to the emergency closure
device.
I hope this information is helpful. Please contact us if we can be of further assistance.
Sincerely,
T. Glenn Foster
Chief, Regulatory Review and Reinvention Branch
Standards and Rulemaking Division

<<<PAGE 6>>>

Please submit this as a letter of interpretation. I spoke with Mr. Olsen.
Mailing Address:
Thatcher Transportation, Inc.
1905 Fortune Road
Salt Lake City, Utah 84104
Please let me know if you have any questions.
Thanks,
Jordan
From: Brent Olsen [mailto:Brent.Olsen@tchem.com]
Sent: Tuesday, March 21, 2017 12:28 PM
To: PHMSA HM InfoCenter <PHMSAHMInfoCenter@dot.gov>
Subject: Interpretation of 172.328(d)
One of our drivers received a violation in Colorado today because the inspector thought the Emergency Shutoff decal on
the left front of the cargo tank should be closer to the actual emergency closure device (a break bolt). Looking at the
picture, the decal appears to be about 4 inches to the right of the device and approximately 12 inches above it (see
picture in attachment).
172.328(d) does not list any specific distance the decal has to be within, but only states that it must be immediately
we ben means oke tr. The existing deal was placed there by the cargo tank manufacturer, and they state
they've been putting it there for as many years as they can remember.
I couldn't find any interpretation specifying the distance, but that's my question. How close does the Emergency Shutoff
decal have to be to the "means of closure" to be immediately adjacent to it? Thank you.
Brent L. Olsen, CDS
Safety Manager
Thatcher Transportation, Inc.
Direct: (801) 924-1413 | M: (801) 833-5148
The information contained in this e-mail message, and any attachments to it, contain confidential, proprietary,
privileged, or otherwise secret information. If you are not the intended recipient, or believe that you may have
received this email or attachments in error, any dissemination, use, review, distribution, printing or copying of
the information contained in this e-mail message and any attachments to it are strictly prohibited. If you have

<<<PAGE 7>>>



<<<PAGE 8>>>

EMERGENCY
SHUTOFF

<<<PAGE 9>>>

To Whom It May Concern,
Usher Transport Inc. is seeking guidance on 172.328(d). We recently received a violation for failing to
mark a manual remote shut-off device as required. The remote shut-off device was marked in two
separate locations. One of the markings was located directly beside the shut-off. That marking was
damaged therefore we received a violation. The secondary marking was in perfect condition and was
located immediately adjacent to the means of closure. I have attached photographs for your review. I
have also attached a PHMSA letter of interpretation that is an exact representation of our situation. The
only difference is the location of our placard holder, which we feel solidifies the location of our
emergency shut-off marking. If we elected to put the shut-off marking on the bulkhead it would have
been located more towards the center line of the tank and therefore the distance would have been
greater. Therefore, we placed the marking in the best location which we believe meets the
interpretation. The state is claiming that our secondary marking does not meet regulation due to the
arrow not pointing at the direct means of closure. Does our secondary marking meet regulations?
See Photo's below:

<<<PAGE 10>>>

OUR ONLY PRODUCT IS SERVICE

<<<PAGE 11>>>

UT
OUR ONLY PRODUCT IS SERVICE
120S
3
EMERGENCYS
INTER

<<<PAGE 12>>>

OUR ONLY PRODUCT IS SERVICE
487
1203
3
INTERNATION

<<<PAGE 13>>>

OUR ONLY PRODUCT IS SERVICE
487

<<<PAGE 14>>>

Respectfully,
Jed Hudson
Safety Manager | Safety & Risk Management
T: (502)449-4000
M: (859)661-2034
jhudson@ushertransport.com - www.ushertransport.com

## Provenance

- Official: Yes
- Source: <https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/2024-08/240043.pdf>
- Source ID: `phmsa`
- SHA-256: `eaf5ec1807b23952e6091cbf2055bc67f2a7669951f52716017347746be06b45`
- Retrieved: 2026-08-20T00:59:31.977Z
- Exported: 2026-08-22T12:53:55.320Z
- Document slug: `phmsa-interpretation-24-0043`

### Source metadata

```json
{
  "materialSubtype": "interpretation",
  "interpretationArea": "hazardous_materials",
  "representation": "full_text_from_official_pdf",
  "companies": [
    "Usher Transport Inc."
  ],
  "individuals": [
    "Jed Hudson"
  ],
  "refIds": [
    "24-0043"
  ],
  "catalogDates": [
    "2024-08-22"
  ],
  "catalogParts": [
    172
  ],
  "catalogRowCount": 1,
  "sourceRecordUrls": [
    "https://www.phmsa.dot.gov/node/75466"
  ],
  "linkedAttachmentUrls": [],
  "unavailableResponseUrls": [],
  "duplicateRepresentationUrls": [],
  "citedSections": [
    "172.328",
    "172.328(d)"
  ],
  "catalogPageUrls": [
    "https://www.phmsa.dot.gov/regulations/title49/section/172328"
  ],
  "pdfUrls": [
    "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/2024-08/240043.pdf"
  ],
  "representations": [
    {
      "viewUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/2024-08/240043.pdf",
      "detailUrl": null,
      "detailHtmlPath": null,
      "pdfUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/2024-08/240043.pdf",
      "pdfArtifactPath": "data/sources/phmsa-interpretations/24-0043-7ac9fa2916.pdf",
      "pdfArtifactSha256": "d6513e8db3e8cabd913e85ca6cc483d8bb6da744b49ecd2520ac7bfa47319f20",
      "extractedTextPath": "data/sources/phmsa-interpretations/24-0043-7ac9fa2916.v2.txt",
      "extractedTextSha256": "b3a6d4161c459298573fce82eac114bc53121f62667a1cb7663e211bcd588777",
      "pageCount": 14,
      "extractionVersion": 2
    }
  ],
  "caveat": "Interpretations apply regulations to the facts presented and do not create independently enforceable requirements.",
  "jurisdiction": "US"
}
```