24-0071 response to AWM Associates, LLC concerning 171.1, 180.407, 180.415.

## Document text

<<<PAGE 1>>>

U.S. Department
of Transportation
Pipeline and Hazardous
Materials Safety
Administration
1200 New Jersey Avenue, SE
Washington, DC 20590
October 17, 2024
Mike Millard
President/Chief Safety Officer
AWM Associates, LLC
7911 Morrow Ave NE
Albuquerque, NM 87110
Reference No. 24-0071
Dear Mr. Millard:
This letter is in response to your August 15, 2024, letter requesting clarification of the Hazardous
Materials Regulations (HMR; 49 CFR Parts 171-180) applicable to cargo tank testing
requirements. Specifically, you ask whether it is a violation of the HMR for a non-DOT
specification cargo tank without a specification plate to be marked with a “V,” indicating it has
passed the external visual inspection in accordance with § 180.407. You state that it is your
understanding that a cargo tank without a specification plate cannot be marked as passing the
external visual test, and that this would be a violation of §§ 180.407(d)(2)(vi), 180.415(a), and
171.1(a). You have also attached two previously issued letters of interpretation (Reference Nos.
17-0026 and 10-0186) which discuss markings on non-specification packagings.
Your understanding is incorrect. The sections you reference do not require the presence of a
specification plate as a condition of performing the testing you describe. As stated in PHMSA’s
previously issued letter of interpretation (Reference No. 17-0026), it is not a violation of the
HMR for a cargo tank owner to voluntarily perform requalification tests on a non-DOT
specification cargo tank and to mark the cargo tank as having passed those tests. However, by
voluntarily applying those markings, the owner of the cargo tank is responsible for performing
those tests in accordance with all HMR requirements.
I hope this information is helpful. Please contact us if we can be of further assistance.
Sincerely,
Alexander Wolcott
Acting Chief, Regulatory Review and Reinvention Branch
Standards and Rulemaking Division

<<<PAGE 2>>>

Larson
24-0071
From: INFOCNTR (PHMSA)
To: Dodd, Alice (PHMSA)
Cc: Hazmat Interps
Subject: FW: Mailed 8/15/2024
Date: Tuesday, August 20, 2024 10:49:45 AM
Attachments: PHMSA Ltr 2024-08-15 tank markings.pdf
Hello Alice,
Please see the attached interpretation request. Let us know if you need anything.
Sincerely,
Janaye
From: awmassociates@gmail.com <awmassociates@gmail.com>
Sent: Thursday, August 15, 2024 5:11 PM
To: INFOCNTR (PHMSA) <INFOCNTR.INFOCNTR@dot.gov>
Subject: Mailed 8/15/2024
CAUTION: This email originated from outside of the Department of Transportation (DOT). Do
not click on links or open attachments unless you recognize the sender and know the content
is safe.
For your consideration.
Mike Millard
President/Chief Safety Officer
Cell: 505-595-5158
Email: AWMAssociates@gmail.com

<<<PAGE 3>>>

AWM Associates, LLC
August 15, 2024
7911 Morrow Ave NE
Albuquerque, NM 87110
Cell: (505) 595-5158
Email: awmassociates@gmail.com
Mr. Shane Kelley
U.S. DOT/PHMSA (PHH-10)
Director, Standards and Rulemaking Division
1200 New Jersey Avenue, SE East Building, 2nd Floor
Washington, DC 20590
Reference: PHMSA Interpretations 17-0026 and 10-0186 test markings for non-DOT packages
Dear Mr. Kelly:
I have questions regarding earlier interpretations by PHMSA regarding marking non-DOT cargo
tanks per 49 CFR Part §180.415 considered the complexity of the HMR?
I have cautioned owners of non-DOT cargo tanks about using the "V" for external visual
inspections per 49 CFR Part §180.407(d)(2)(vi) "All markings on the cargo tank required by parts 172,
178 and 180 of this subchapter must be legible;" If the DOT specification plate is absent, how can the
non-DOT cargo tank be marked as passing the external visual test?
I consider the issue to be a violation of 49 CFR Part §180.407(d)(2)(vi), Part §180.415(a) "Each
cargo tank successfully completing the test and inspection requirements contained in §180.407 must
be marked as specified in this section.," and Part §171.1(a) "Packagings. Requirements in the HMR
apply to each person who manufactures, fabricates, marks, maintains, reconditions, repairs, or tests a
packaging or a component of a packaging that is represented, marked, certified, or sold as qualified for
use in the transportation of a hazardous material in commerce, including each person under contract
with any department, agency, or instrumentality of the executive, legislative, or judicial branch of the
Federal government who manufactures, fabricates, marks, maintains, reconditions, repairs, or tests a
packaging or a component of a packaging that is represented, marked, certified, or sold as qualified for
use in the transportation of a hazardous material in commerce."
I have no issues with the "f" for internal inspection, "P" for pressure retest or "K" for leakage
test; however, without a DOT specification plate per Part §178.345-14 a non-DOT cargo tank cannot be
marked with a "V" indicating it passed an external inspection per Part §180.407(d)(2)(vi.) I believe the
"V" marking is a violation of Part §180.415(a) and Part §171.1(a) as the "V" marking implies the non-
DOT package fully meets the requirements of the HMR 49 CFR Parts §100 through $199.
Page 1 of 2

<<<PAGE 4>>>

I have attached the referenced interpretations for your review. I appreciate your time in
responding to my request for a written interpretation regarding the marking of non-DOT cargo tanks with
test markings required per 49 CFR Part §180.415.
Sa
6 - 20 кр
"EVERGENCY!
VIPK markings on a non-DOT tank transporting diesel fuel.
Sincerely;
Tin sun
Michael Millard
President & Chief Safety Officer
Attachments:
Page 2 of 2

<<<PAGE 5>>>

PHMSA Interpretation
Reference No. 17-0026

<<<PAGE 6>>>

of Transportation
U.S. Department
Washington, DC 20590
1200 New Jersey Avenue, SE
Pipeline and Hazardous
Materials Safety
Administration
AUG 1 5 2017
John Hardridge
Instructor
3908 Vista Drive
Norman, OK 73071
Reference No. 17-0026
Dear Mr. Hardridge:
This letter is in response to your March 9, 2017, email requesting clarification of the Hazardous
Materials Regulations (HMR; 49 CFR Parts 171-180) applicable to cargo tank requalification
testing and marking. Specifically, you describe a scenario where a person voluntarily marks the
retest date and the retest identification marking on a cargo tank in accordance with Part 180,
registration number.
Subpart E. You further note the cargo tank does not have a specification plate, special permit, or
We have paraphrased and answered your questions as follows:
Q1. You ask whether the HMR permit a person to perform requalification tests and apply
tank when not required.
associated markings on a non-Department of Transportation (DOT) specification cargo
The answer is yes. Nothing in the HMR prohibits a cargo tank owner from voluntarily
performing requalification tests on a non-DOT specification cargo tank. Typically, a
non-DOT specification cargo tank is not subject to the periodic inspection or retest
requirements of the HMR. However, the HMR include scenarios where a non-DOT
specification cargo tank must undergo certain requalification testing and marking in Part
100, Subpart E. For example, § 173.315(m)(2) specifies conditions where non-DOT
be marked in accordance with § 180.415.
specification cargo tanks containing anhydrous ammonia require certain testing and must
Q2.
You ask whether a person who voluntarily tests and marks a non-DOT specification
cargo tank in accordance with Part 180, Subpart E is subject to performing the applicable
tests and applying the retest markings in accordance with the HMR.
A2.
The answer is yes. Under § 171.2(g), no person may represent, mark, or offer a
marked, and retested in accordance with the applicable requirements. Section 171.2(h)(3)
packaging as meeting the requirements of the HMR unless the packaging is maintained,
specifies that test dates are subject to paragraph (g) when associated with the

<<<PAGE 7>>>

"specification, registration, approval, retest, exemption, or special permit markings" that
indicate HMR compliance. Therefore, if the "test date" and "retest" identification
the test and marking must be followed.
markings are both applied to the cargo tank, then the applicable HMR requirements for
I hope this information is helpful. Please contact us if we can be of further assistance.
Sincerely,
T. Glenn Foster
Chief, Regulatory Review and Reinvention Branch
Standards and Rulemaking Division

<<<PAGE 8>>>

Achman
'71•2
Goodall, Shante CTR (PHMSA)
Genual resuinement
From:
17 - 00210
Sent:
INFOCNTR (PHMSA)
To:
Thursday, March 09, 2017 2:46 PM
Subiect:
Hazmat Interps
FW: Request for interpretation on cargo tank testing of non-spec tanks
Hi Shante/Alice,
Please submit this as a letter of interpretation. Mr. Hardridge spoke with Eamonn.
Please let me know if you have any questions.
Thanks,
Jordan
From: ohp31@yahoo.com [mailto:ohp31@yahoo.com]
Sent: Thursday, March 09, 2017 1:19 PM
To: INFOCNTR (PHMSA) < INFOCNTR. INFOCNTR@dot.gov>
Subject: Request for interpretation on cargo tank testing of non-spec tanks
To whom it may concern.
There has been some controversy over enforcement of test date markings on a non-specification cargo tanks
used to transport combustible liquids.
The first piece of information and question involved is as follows:
Situation: An owner of a non-specification cargo tank wishes to test and retest his cargo tank according to Part
180 Subpart D and mark the tank accordingly, even though not required.
violation of Part CFR 49 Part 171.2(h)?
Question #1: Is the person conducting the tests and marking the test and test dates on the non-spec tank in
Resulting Enforcement Actions: I have seen some enforcement agencies taking enforcement actions on
persons who have voluntarily performed tests and retests of non-spec cargo tanks and have marked said tanks
with the test date makings in Part 180. These tests have been conducted to reassure the owners that the tanks
involved are in good condition. The test and test date markings are shown as a convenient way to tell the owner
when he should conduct the next test or tests. Basically, the owner is complying with the test and marking
requirements in Part 180 even though not required. The enforcement agencies involved claim that this is a
"test dates associated with the specification....
violation of 171.2(g) due to the next paragraph (h) stating that the prohibition of displaying markings includes:
Involved Regulations:

<<<PAGE 9>>>

171.2(g) No person may represent, mark, certify, sell, or offer a packaging or container as meeting the
requirements of this subchapter governing its use in the transportation of a hazardous material in commerce
unless the packaging or container is manufactured, fabricated, marked, maintained, reconditioned, repaired, and
retested in accordance with the applicable requirements of this subchapter.
171.2(h) The representations, markings, and certifications subject to the prohibitions of paragraph (g) of this
section include:
(1) Specification identifications that include the letters "ICC", "DOT", "CT", "MC", or "UN";
or "R"; and
(2) Exemption, special permit, approval, and registration numbers that include the letters "DOT", "EX", "M",
(3) Test dates associated with specification, registration, approval, retest, exemption, or special permit
markings indicating compliance with a test or retest requirement of the HMR, or an exemption, special permit,
approval, or registration issued under the HMR or under subchapter A of this chapter.
Comments: The way I have always understood Part 171.2(h) is that the only way to misrepresent a cargo tank
as a specification tank, when it is not, is if a specification plate with a certification date is display on a non-spec
tank or a tank that does not completely meet the requirements of the specification named on the plate.
The requirement in 171.2(h)(3) dealing with "Test dates associated with specification..." seems to only imply
that it is prohibited to display retest dates on a specification cargo tank when the tests indicated by the marking
have not been conducted or were conducted improperly. I do not see how markings of tests and tests
dates could be interpreted as representing a non-specification tank as a specification tank when the tests were
properly conducted according to Part 180, Subpart D, even though it is not required.
If the action above is not a violation of Part 171.2, then the second piece of information and question would
be:
Situation: The owner of a non-spec tank chooses to test and mark said cargo tank as required for spec tanks in
is safe.
Part 180. Even though not required, the person follows the regulations as a convenient way to assure the tank
violation for not testing and marking correctly?
Question #2: If that person does not follow the retest and marking regulation exactly as written, is the person in
If you should have questions or need clarifications regarding this request, please do not hesitate to contact me.
Respectfully,
3908 Vista Drive
John Hardridge, Independent Instructor for Hazardous Material Transportation Regulations
Norman, OK. 73071
Phone: (405) 413-7451
E-mail: ohp31@yahoo.com
2

<<<PAGE 10>>>

PHMSA Interpretation
Reference No. 10-0186

<<<PAGE 11>>>

U.S. Department of Transportation
Safety Administration
Pipeline and Hazardous Materials
Washington, D.C. 20590
1200 New Jersey Ave, SE
OCT 29 2010
Ms. Erin N. Jarman
URS Corporation
1600 Perimeter Park Drive, Suite 400
Morrisville, NC 27560
Reference No.: 10-0186
Dear Ms. Jarman:
This responds to your September 1, 2010 letter regarding packaging requirements for diesel fuel
under the Hazardous Materials Regulations (HMR; 49 CFR Parts 171-180). Your questions are
paraphrased and answered as follows:
Q1.
Is it possible for a packaging to be tested and dual-marked as both an Intermediate Bulk
Container (IBC) and a portable tank?
Al.
The answer is no. An IBC is defined by the HMR as a rigid or flexible portable packaging,
(see § 171.8).
other than a cylinder or specification portable tank, that is designed for mechanical handling
Q2.
If an IBC has not been tested according to the retest requirements set forth in 49 CFR Part
178, Subpart O, must the UN marking be removed or obliterated to continue to be used?
A2.
The requirements applicable to IBC retesting are set forth in 49 CFR Part 178, Subpart O and
reference specifically Part 180, Subpart D. As provided by § 173.35, when an IBC is
identified as an UN specification container by the specification plate, it must meet the
specification and be retested in accordance with Part 180, Subpart D regardless of whether
the material is hazardous or not. If an IBC has not been retested, one must obliterate, cover,
or make illegible the specification identification on the specification plate in order for the
IBC to continue to be used as a non-specification container without being retested.
Q3.
By removing or obliterating the UN Marking of the IBC, it is our understanding based on
specification bulk packaging. Is that correct?
DOT interpretation Letter Ref. No. 08-0286 that this packaging could be considered a non-
A3.
The answer is yes. The previously issued interpretation (Ref. No. 08-0286) you cite in your
inquiry remains valid. Because the specification markings are destroyed, removed, or

<<<PAGE 12>>>

covered, the packaging no longer meets the standards of an IBC in accordance with the
HMR. The packaging in your scenario is a non-specification bulk packaging.
Q4.
If the answer to Q3 is yes, could this non-specification bulk packaging satisfy the packaging
for the transportation of high flashpoint diesel fuel?
requirements found in § 173.241, which permits the use of non-specification portable tanks
A4.
The answer is yes. If the specification markings are destroyed, removed, or covered, the
packaging no longer meets the standards of a specification packaging in accordance with the
a non-specification portable tank. In accordance with § 172.102 special provision B1, a
HMR. Therefore, the packaging is a non-specification bulk packaging and can be considered
material with a flash point at or above 38° C (100° F) and below 93° C (200° F) can use the
bulk packaging requirements in § 173.241, which allow for the use of non-specification
portable tanks.
I hope this satisfies your inquiry. Please contact us if we can be of further assistance.
Sincerely,
I Mean Fest
T. Glenn Foster
Chief, Regulatory Review and Reinvention
Office of Hazardous Materials Standards

<<<PAGE 13>>>

Benedict
§172.101
§173.241.
URS
Bulk Packaging
10 - 0186
September 1, 2010
Director, Office of Hazardous Materials Standards
Mr. Charles E. Betts
U.S. DOT/PHMSA (PHH-10)
Washington, DC 20590
1200 New Jersey Avenue, SE East Building, 2nd Floor
Dear Mr. Betts:
I am writing to you with regards to the packaging requirements for diesel fuel under 49 CFR §172.102,
Special Provision B1. Specifically, Special Provision B1 states the following:
"If the material has a flash point at or above 38° C (100° F) and below 93° C (200° F), then the bulk
packaging requirements of §173.241 of this subchapter are applicable."
In addition to other types of packaging, 49 CFR §173.241 permits the use of non-DOT specification
portable tanks suitable for the transport of liquids. It also permits the use of various intermediate bulk
container (IBC) types.
excludes portable tanks, however the definition of "portable tank" in that same section seems to describe
Per the definition for "intermediate bulk container" found in 49 CFR §172.101, the term specifically
accessories to facilitate handling of the tank by mechanical means."
typical IBCs that are used in industry, since many of them are "equipped with skids, mountings, or
My questions are as follows:
1) Is it possible for a packaging to be tested and dual marked as both an IBC and a portable tank?
2) If an IBC has not been tested according to the retest requirements set forth in 49 CFR Part 178, Subpart
O, must the UN marking be removed or obliterated to continue being used?
By removing or obliterating the UN marking of the IBC, it is our understanding based on DOI
bulk packaging. Is that correct?
Interpretation Letter Ref. # 08-0286 that this packaging would then be considered a non-specificatior
4) If the answer to Question 3 is YES, could this non-specification bulk packaging satisfy the packaging
transportation of high flash point diesel fuel?
requirements found in $173.241 which permits the use of non-specification portable tanks for the
Thank you in advance for your assistance. I look forward to your response.
Sincerely,
Erin 2. Jarmar
Environmental Scientist
Erin N. Jarman
URS Corporation
Morrisville, NC 27560
1600 Perimeter Park Drive. Suite 400
Tel: 919-461-1478
Erin_Jarman@urscorp.com

## Provenance

- Official: Yes
- Source: <https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/2025-03/240071.pdf>
- Source ID: `phmsa`
- SHA-256: `49ca33f41bf89e364d1bd2ddeaeca64c789b46dad7035a9a4812d78d6acd29aa`
- Retrieved: 2026-08-20T00:59:31.977Z
- Exported: 2026-08-23T05:49:40.347Z
- Document slug: `phmsa-interpretation-24-0071`

### Source metadata

```json
{
  "materialSubtype": "interpretation",
  "interpretationArea": "hazardous_materials",
  "representation": "full_text_from_official_pdf",
  "companies": [
    "AWM Associates, LLC"
  ],
  "individuals": [
    "Mike Millard"
  ],
  "refIds": [
    "24-0071"
  ],
  "catalogDates": [
    "2024-10-17"
  ],
  "catalogParts": [
    171,
    180
  ],
  "catalogRowCount": 3,
  "sourceRecordUrls": [
    "https://www.phmsa.dot.gov/node/76706"
  ],
  "linkedAttachmentUrls": [],
  "unavailableResponseUrls": [],
  "duplicateRepresentationUrls": [],
  "citedSections": [
    "171.1",
    "171.1(a)",
    "180.407",
    "180.415",
    "180.415(a)",
    "178.345",
    "173.315(m)(2)",
    "171.2(g)",
    "171.8",
    "173.35",
    "173.241",
    "172.102",
    "172.101"
  ],
  "catalogPageUrls": [
    "https://www.phmsa.dot.gov/regulations/title49/section/1711",
    "https://www.phmsa.dot.gov/regulations/title49/section/180407",
    "https://www.phmsa.dot.gov/regulations/title49/section/180415"
  ],
  "pdfUrls": [
    "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/2025-03/240071.pdf"
  ],
  "representations": [
    {
      "viewUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/2025-03/240071.pdf",
      "detailUrl": null,
      "detailHtmlPath": null,
      "pdfUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/2025-03/240071.pdf",
      "pdfArtifactPath": "data/sources/phmsa-interpretations/24-0071-a8043bb254.pdf",
      "pdfArtifactSha256": "39c1d727858e7f596010e25bee52e290c0dc7325839559d879e4885055a3a61f",
      "extractedTextPath": "data/sources/phmsa-interpretations/24-0071-a8043bb254.v2.txt",
      "extractedTextSha256": "516a1f8edc33f0bf748234da274c2b3e4a5c94a13ac70de46f84bc4ec34bfe4e",
      "pageCount": 13,
      "extractionVersion": 2
    }
  ],
  "caveat": "Interpretations apply regulations to the facts presented and do not create independently enforceable requirements.",
  "jurisdiction": "US"
}
```