<<<PAGE 1>>>

U.S. Department
of Transportation
400 Seventh Street, S.W.
Washington, D.C. 20590
Research and
Administration
Special Programs
•
SEP 2 | 1993
Mr. Edward Yarmak, Jr., P.E.
Chief Engineer
Arctic Foundations, Inc.
•
98-0273
5621 Arctic Boulevard
Anchorage, Alaska 99518-1667
Dear Mr. Yarmak:
This is in response to your letter dated September 8, 1998 requesting clarification of the
requirements in § 173.306 (e), under the Hazardous Materials Regulations (HMR; 49 CFR parts
171-180). Specifically, you ask whether your devices, which you refer to as Thermopiles and
hermoprobes, meet the defining criteria for refrigeration machines.
The HMR govern the transportation of hazardous materials in commerce. Under § 173.22, it is
the shipper's responsibility to properly classify a hazardous material or determine that it does not
meet a hazard class definition in Part 173. If your devices conforms to the defining criteria
identified in § 173.306 (e), it is the opinion of this office that they would be considered to be
Refrigerating machines.
If we can be of further assistance, please feel free to contact us.
Sincerely,
Hattie L. Mitchell, Chief
Regulatory Review and Reinvention
Office of Hazardous Materials Standards

<<<PAGE 2>>>

:
ARCTIC FOUNDATIONS, INC.
Betts
8173.306
September 8, 1998
Ryan Posten
Transportation Regulation Specialist
Regulatory Review and Reinvention
U.S. Department of Transportation
Research and Special Programs Administration
Office of Hazardous Materials Standards - DHM10
Washington, DC 20590
Re:
Interpretation of 173.306 (e) with regard to Thermopiles and Thermoprobes
Dear Mr. Posten:
On August 31, 1998, Mr. Ron Abis and Mr. David Robertson of the USDOT met with us
concerning the shipping of the products that we manufacture. We believe that they fall
under a standard exception, and that is 173.306(e) for refrigeration machines. We will
belief is correct.
detail our products to you so that you can make an interpretation as to whether our
Arctic Foundations, Inc. manufactures passive refrigeration devices that are used to
freeze soil. These devices are generally known as thermosyphons and use natural
temperature differentials between the cold winter air and the soil to operate. There are
description follows:
no external energy inputs required for the devices to properly operate. A detailed
Thermosyphons are typically constructed using pipe tubing with closed ends. The
sealed vessel is charged with a fixed quantity of working fluid so that there are
predetermined volumes of vapor and liquid fractions contained in the vessel. The
portion of the thermosyphon exposed to the air is the condenser and the buried portion
is the evaporator. In normal applications, the evaporator is not completely full of
liquid. Whenever the condenser end of the thermosyphon is cooler than the evaporator
ondensate evaporates from the side of the vessel before reaching the bottom. Th
na, the vapor condenses and returns by gravity to the evaporator. Most of th
latent heat absorbed on evaporation of the liquid and subsequently released upon
condensation of the vapor is responsible for the high heat transfer conductances typical
of thermosyphons.
562 | Arctic Boulevard • Anchorage, Alaska 99518-1667
Phone: (907) 562-2741 • Fax: (907) 562-0153 • Internet: arcfnd@alaska.net

<<<PAGE 3>>>

Arctic Foundations, Inc.
September 4, 1998
Page 2
More specifically, Arctic Foundations, Inc. builds thermosyphons in accordance with
Section VIII, Division 1 of the ASME Boiler and Pressure Vessel Code. Fill ratios are
generally less than 10% and usually approach 3% for most units. Welded construction
is used with standard pipe and semi-elliptic ends. Carbon Dioxide, R-744, is our
refrigerant of choice; however, various other refrigerants have been used including R-
11, K-12, K-22, K-290, and R-600. Thermosyphons charged with carbon dioxide are
typically designed for a maximum allowable working pressure of 750psi. Materials of
construction are generally mild steel. Fabrication is by welding. These units are
shipped from our plant to the project site where they are installed. Shipping may be by
truck, rail, barge or air. Once installed, the units are anchored to the earth, providing
subgrade refrigeration for the facility to prevent permafrost degradation.
Should you require additional information, please contact us at your convenience.
Very truly yours,
Chlay of
Edward Yarmak, Jr., P. E.
Chief Engineer
EX/rlp

<<<PAGE 4>>>

1.
(:))
SEP 9 98
.·0.32
ARCTIC FOUNDATIONS, INC.
5621 Arctic Boulevard • Anchorage, Alaska 99518-1667
Ryan Posten
Transportation Regulation Specialist
Regulatory Review and Reinvention
U. S. Department of Transportation
Research and Special Programs Administration
Office of Hazardous Materials Standards - DHM10
400 Seventh Street, S. W.
Washington, DC 20590
-. -
....-
....

## Provenance

- Official: Yes
- Source: <https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/1998/980273.pdf>
- Source ID: `phmsa`
- SHA-256: `1d0487fb2cd5698bb5eae474b6fdd4e8abf8860f9b76e4a04fbc7da5faf6405e`
- Retrieved: 2026-08-20T00:59:31.977Z
- Exported: 2026-08-22T21:22:50.343Z
- Document slug: `phmsa-interpretation-98-0273`

### Source metadata

```json
{
  "materialSubtype": "interpretation",
  "interpretationArea": "hazardous_materials",
  "representation": "full_text_from_official_pdf",
  "companies": [
    "Arctic Foundations, Inc."
  ],
  "individuals": [
    "Mr. Edward Yarmak, Jr., P.E."
  ],
  "refIds": [
    "98-0273"
  ],
  "catalogDates": [
    "1998-09-21"
  ],
  "catalogParts": [
    173
  ],
  "catalogRowCount": 1,
  "sourceRecordUrls": [
    "https://www.phmsa.dot.gov/node/44846"
  ],
  "linkedAttachmentUrls": [],
  "unavailableResponseUrls": [],
  "duplicateRepresentationUrls": [],
  "citedSections": [
    "173.306",
    "173.22"
  ],
  "catalogPageUrls": [
    "https://www.phmsa.dot.gov/regulations/title49/section/173306"
  ],
  "pdfUrls": [
    "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/1998/980273.pdf"
  ],
  "representations": [
    {
      "viewUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/1998/980273.pdf",
      "detailUrl": null,
      "detailHtmlPath": null,
      "pdfUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/1998/980273.pdf",
      "pdfArtifactPath": "data/sources/phmsa-interpretations/98-0273-832cdc0137.pdf",
      "pdfArtifactSha256": "7b06218ae26917ade0fec7ba2002bcbce26bf1667b7b6ccf206cc9810a6e2514",
      "extractedTextPath": "data/sources/phmsa-interpretations/98-0273-832cdc0137.v2.txt",
      "extractedTextSha256": "423d1d34da1efba67ac4fbcfcc084eeee35fcf6050f56caec18c60df2465cd99",
      "pageCount": 4,
      "extractionVersion": 2
    }
  ],
  "caveat": "Interpretations apply regulations to the facts presented and do not create independently enforceable requirements.",
  "jurisdiction": "US"
}
```