<<<PAGE 1>>>

minus.
U.S.Department
of Transportation
400 Seventh Street, S.W
t
1
Special Program:
Research and
APR 1 7 1998
Washington, D.C. 20590
Administration
Mr. Gary P. Velikanje
President
Wood Kote Products, Inc
8000 N.E. 14th Place
Portland, OR 97211
1
Dear Mr. Velikanje:
This is in response to your letter of October 16, 1997, regarding the packaging of a two component
wood bleach kit consisting of an aqueous solution of hydrogen peroxide (28%) and an aqueous
solution of sodium hydroxide with a buffer of silicic acid. You request clarification under the
provisions of the Hazardous Materials Regulations (HMR; 49 CFR Parts 171-180).
i
Specifically, you asked if a two part kit consisting of one inner container of a material described as
Hydrogen peroxide, aqueous solution, 5.1, UN 2014 with a Class 8 subsidiary hazard, and one inner
:
container of a material describe as Sodium hydroxide solution, 8, UN 1824, PG II may be placed
in the same outside packaging for transport by vessel. You expressed concern that ocean carriers will
not accept these shipments although they have been prepared in accordance with the HMR and the
International Maritime Dangerous Goods (IMGD) Code.
Yes, these materials may be packaged together in the same outside package provided they are in
accordance with 49 CFR 173.21 (e). As indicated in paragraph 3.6 in Annex I of the General
Introduction to the IMDG Code, Amendment 28 (see IMDG Code page 0509), a corresponding
provision specifies that materials may not be packaged together in the same outer packaging with
other material it they react dangerously to each other and cause combustion and/or evolution of
considerable heat, evolution of flammable, poisonous or asphyxiate gases, or the formation of
corrosive or unstable substances.
In addition, it is the shippers responsibility to ensure that your materials are properly packaged,
marked and labeled. Each material within the package, must be described on the shipping paper and
marked on the outside package. The package must be labeled with a Division 5.1 label and a Class
8 label for the primary hazard of the materials.
I hope that this information is helpful. If you need further assistance, please contact us.
Sincerely,
DelmerF. Billings
Chief, Regulations Development
Office of Hazardous Materials Standards

<<<PAGE 2>>>

OCT-16-97
04:40 PM
WOOD. KOTE. PRODUCTS. INC
503 285 8374
P. 02
• "
File: 11321
WOOD-KOTE®
MANUFACTURERS OF WOOD FINISHES
16 October, 1997
Office of Hazardous Materials Standards
Edward T Mazzullo, Director
Research and Special Programs Administration
US DEPARTMENT OF TRANSPORTATION
Washington DC 20590
400 7th st SW
:
•
Via: Fax (202-366-8700) and USPS Priority Mail
Re: Request for clarification
Mr Mazzullo:
I am willing to request the assistance of your office. We manufacture and market a two
component Wood Bleach kit, The components are: Part "A", an aqueous solution of Hydrogen
Peroxide (28%) and Part "B", an aqueous solution of Sodium Hydroxide with a buffer of Stlicic : ::..
Acid. Each component is packaged in heavy duty polyethylene bottles (16 oz, 32 oz or 1 gal).
ne two poles for the 16 oz and 32 oz kits are then enclosed in a plastic bag which is the
laced into a light weight fiberboard box and then packed 6 kits in a UN specified heavy weigl
"peroard carton with each Part "A" component enclosed in a plastic bag,
fiberboard cartor. The gallon kits are packaged with 2 kits per UN specified heavy weight
Should the two components leak and combine they will not react clangerously with each other,
•
•
or vapors, or the formation of corrosive or unstable substances. The two components combined
cause combustion or evolution of considerable heat, evolution of flammable or poisonous gases
are, in fact, less dangerous than cach individually.
I have, for your reference, enclosed the following MSDS'S:
Part "A"
Product Description
Product Code
Part "B"
800-WB-A
Part "A" & "B" combined ratio 1:1
800-WB-B
800-WB-B
1 am also enclosing photocopies of letters you have provided to the WM Barr Co. Our wood
labeling is reversed. Our concern is the same as WM Barr's addressed in your 08 November
bleach is equivalent to the Klean-Strip Wood Bleach they produce except the "A" and "B"
wood bleach and would like to have clarification addressed to Wood Kote to present to the
1995, leller. We want to be able to make domestic and international marine shipments of our
shipping authorities.
Would it be possible for you to provide a clarification letter addressed to Wood Kote which states
segregation requirements chumerated in the IMDG Code page 0129 15.1.16 and 49CFR Sec
that our wood Bleach components are compatible for shipment together and therefore the
176.83(b) & (c) (2) (ill) do not apply?
8000 N.E. 14th Place - Portfand, Oregon 97211 USA • P.O. Box 17192 - Portland, Oregon 97217 USA
Tel: 503-285-8371 • 800-843-7666 (USA & Canada) : Fax: 503-285-8374
E-Mail: woadkote@teleport.com • Home name: htt://www.wnndkote.com

<<<PAGE 3>>>

0CT-16-97 04:41 PM WOOD. KOTE. PRODUCTS. INC
503 285 8374
P.03
assume you may have questions and may require additional Information before you can issue
843-7666 or fax 503-285-8374.
he documentation we are seeking. If so, please do not hesitate to contact us by telephone, 800.
I thank you, in advance, for your prompt attention to this matter.
Yours truly.
Gaty P Velikanje, President
WOOD KOTE PRODUCTS, INC
•
enclosures
cG: T Nash
...
••
•

## Provenance

- Official: Yes
- Source: <https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/1998/980509.pdf>
- Source ID: `phmsa`
- SHA-256: `e4ead3cff7f420a17819cf4ae42a8aca982560df91ec8a42b1246d5c81e03373`
- Retrieved: 2026-08-20T00:59:31.977Z
- Exported: 2026-08-22T21:22:38.709Z
- Document slug: `phmsa-interpretation-98-0509`

### Source metadata

```json
{
  "materialSubtype": "interpretation",
  "interpretationArea": "hazardous_materials",
  "representation": "full_text_from_official_pdf",
  "companies": [
    "Wood Kote Products, Inc"
  ],
  "individuals": [
    "Mr. Gary P. Velikanje"
  ],
  "refIds": [
    "98-0509"
  ],
  "catalogDates": [
    "1998-04-17"
  ],
  "catalogParts": [
    173
  ],
  "catalogRowCount": 1,
  "sourceRecordUrls": [
    "https://www.phmsa.dot.gov/node/69311"
  ],
  "linkedAttachmentUrls": [],
  "unavailableResponseUrls": [],
  "duplicateRepresentationUrls": [],
  "citedSections": [
    "173.21",
    "176.83(b)"
  ],
  "catalogPageUrls": [
    "https://www.phmsa.dot.gov/regulations/title49/section/17321"
  ],
  "pdfUrls": [
    "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/1998/980509.pdf"
  ],
  "representations": [
    {
      "viewUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/1998/980509.pdf",
      "detailUrl": null,
      "detailHtmlPath": null,
      "pdfUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/1998/980509.pdf",
      "pdfArtifactPath": "data/sources/phmsa-interpretations/98-0509-bc5036410f.pdf",
      "pdfArtifactSha256": "b11a50da90d8b2c222471879dc0d03761bec5a61cbf754d053cf6afbf26ee55b",
      "extractedTextPath": "data/sources/phmsa-interpretations/98-0509-bc5036410f.v2.txt",
      "extractedTextSha256": "58aa6c9028657f627e8a6b1d2f3324b34366ff7855c0f3482a6ed6dc06e5fe07",
      "pageCount": 3,
      "extractionVersion": 2
    }
  ],
  "caveat": "Interpretations apply regulations to the facts presented and do not create independently enforceable requirements.",
  "jurisdiction": "US"
}
```