# Manufacturers Standardization Society of the Valve Fittings Industry — Pipeline Safety Interpretation

**Citation:** PI-73-038  
**Type / status:** guidance / guidance  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective:** Not stated  
**Published:** 1973-12-05

PI-73-038 response to Manufacturers Standardization Society of the Valve Fittings Industry concerning 192.149.

## Document text

<<<PAGE 1>>>

Dec 5 1973
Mr. Robert V. Warrick
Manufacturers Standardization Society
of the Valve Fittings Industry
1815 North Fort Myer Drive
Arlington, VA 22209
Dear Mr. Warrick:
This is in response to your letter of October 26, 1973, and our conference on November 15
together with Messrs. Greenwald, Lattan, and George, representing the Manufacturers
Standardization Society of the Valve and Fitting Industry regarding our interpretation of
§192.149.
You indicate that the interpretation of §192.149 in our August 10, 1973, letter to Mr. R.W.
Schneider has created considerable concern among manufacturers of these products and that you
feel that the interpretation is in contradiction to that given to your office on November 9, 1970.
First of all, from the discussion in our conference regarding the last sentence of §192.149(b), we
feel that the sentence should be clarified to properly interpret the need for testing of a prototype.
A clarification of that sentence, with parenthetical insertion added, would then read:
"...The actual bursting strength of the fitting must be at least equal the computed bursting
strength of pipe of the designated material and wall thickness, as determined by as
prototype that was tested to at least the (computed bursting) pressure required for the
pipeline to which it is being added."
We stated in the letter to Mr. Schneider that "...in the case of bursting strength requirements for a
particular fitting made in accordance with certain design specifications, size, material properties,
and manufacturing process, such a new fitting would be tested to burst. After satisfactory test,
any number of like fittings would be expected to meet strength requirements for such a type
fitting" (underscoring added). This statement sets forth clearly the intent that any new type of
fitting must have a prototype tested to burst. Any number of like fittings are then expected to
meet similar strength requirements.
We then indicated in that letter that "If there is a change in size, material, design specifications,
manufacturing process, or any other thing that could affect the performance, it would be expected
that such a change would necessitate the testing of a new prototype."
The interpretation given to Mr. Schneider in our letter of August 10, 1973, was not in direct
contradiction of the interpretation given to your office on November 9, 1970, but only clarified
dal\192\149\73-12-05
1

<<<PAGE 2>>>

our understanding of the words "lines of fittings" used in your description of the specific practices
in your letter of November 9, 1970, as meaning "like" fittings of the same design "specifications,
size, material properties and manufacturing process."
If you feel that this testing of the prototype fittings should be modified, you may petition this
Office to amend this rule. This petition should set forth the substance of the rule proposed,
explain the interest of the petitioner, and contain information to support the action sought. Based
upon the information you provide, we will evaluate this information and consider regulatory
action in this matter.
We trust that this has clarified this matter. If we can be of further assistance, please let us know.
Sincerely,
Cesar DeLeon
Deputy Director
Office of Pipeline Safety
dal\192\149\73-12-05
2

## Provenance

- Official: Yes
- Source: <https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1973/PI73038.pdf>
- Source ID: `phmsa`
- SHA-256: `405ccdc53624e956e5c5f27de4f2877a98a543dc7640f70e85cbc0d670409bc4`
- Retrieved: 2026-08-20T00:59:31.977Z
- Exported: 2026-08-23T09:22:03.279Z
- Document slug: `phmsa-interpretation-pi-73-038`

### Source metadata

```json
{
  "materialSubtype": "interpretation",
  "interpretationArea": "pipeline_safety",
  "representation": "full_text_from_official_pdf",
  "companies": [
    "Manufacturers Standardization Society of the Valve Fittings Industry"
  ],
  "individuals": [
    "Robert V. Warrick"
  ],
  "refIds": [
    "PI-73-038"
  ],
  "catalogDates": [
    "1973-12-05"
  ],
  "catalogParts": [
    192
  ],
  "catalogRowCount": 1,
  "sourceRecordUrls": [
    "https://www.phmsa.dot.gov/node/58436"
  ],
  "linkedAttachmentUrls": [],
  "unavailableResponseUrls": [],
  "duplicateRepresentationUrls": [],
  "citedSections": [
    "192.149"
  ],
  "catalogPageUrls": [
    "https://www.phmsa.dot.gov/regulations/title49/section/192149"
  ],
  "pdfUrls": [
    "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1973/PI73038.pdf"
  ],
  "representations": [
    {
      "viewUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1973/PI73038.pdf",
      "detailUrl": null,
      "detailHtmlPath": null,
      "pdfUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1973/PI73038.pdf",
      "pdfArtifactPath": "data/sources/phmsa-interpretations/pi-73-038.pdf",
      "pdfArtifactSha256": "bc8c22d27246fddcd219379534af7902bc6a66f6f4a17fd75e7ab071e5290275",
      "extractedTextPath": "data/sources/phmsa-interpretations/pi-73-038.v2.txt",
      "extractedTextSha256": "e9b55b255e2b4be8895515f1b4f4d780f1ebd0b2b9c27feba4365de2d7a2d485",
      "pageCount": 2,
      "extractionVersion": 2
    }
  ],
  "caveat": "Interpretations apply regulations to the facts presented and do not create independently enforceable requirements.",
  "jurisdiction": "US"
}
```