# Pipeline Safety Interpretation PI-81-0112

**Citation:** PI-81-0112  
**Type / status:** guidance / guidance  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective:** Not stated  
**Published:** 1981-08-18

PI-81-0112 concerning 192.145.

## Document text

<<<PAGE 1>>>

PI-81-0112
August 18, 1981
Mr. E. L. Schmitt
Nicotine Manufacturing Corporation
1525 Liberty Avenue
Pittsburgh, PA. 15222
Dear Mr. Schmitt:
This refers to you letter of April 16, 1981, in which you requested the advice of this office on what action you should
take so that the use of malleable iron covers on you275 WOG valves will conform to applicable standards in 49 CFR part
192. As you noted in your letter, §192.145 requires that valves meet the minimum requirements, or the equivalent, of
the industry standard, API 6A, API 6D, or MSS SP-70, all three of which require steel covers to be used on you 275 WOG
valves.
Since §192.145 permits the equivalent of the standard quoted above to be used, you may use a malleable iron cover in
complying with §192.145 if it can be demonstrated that the 275 WOG valve constructed with a malleable iron cover
would provide at least the same level of safety under expected operating conditions as one constructed with a steel
cover. You may use any qualified expertise in making this determination, but one source, of course, would be industry
groups responsible for the quoted standards. This office does not make equivalency determinations for manufacturers
or operators; however, Federal or State inspection personnel may judge the correctness of any determination as part of
their enforcement duties when visiting an operator’s facilities.
To answer your question as to whether you should formally request a waiver, if equivalency is demonstrated there is no
need for a waiver since §192.145 would be satisfied. Moreover, section 3 of the Natural gas Pipeline Safety Act of 1968,
as amended by Title 1 of the Pipeline Safety Act of 1979, permits the secretary of transportation to grant waivers only to
persons engaged in the transportation of gas or the operation of pipeline facilities. Since it appears that you are engaged
in the manufacturing of components for gas pipelines and not in the transportation of gas or operation of pipeline
facilities, you would not fall into the category of petitioners to whom a waiver could be granted.
If equivalency cannot be demonstrated but there is reason to believe the 275 WOG valve can be used safely under
expected operating conditions, you may petition us to amend §192.145 to allow the use of 275 WOG type valves with
malleable iron covers in gas pipelines. Such a petition should clearly set forth the reasons why the valve should be
permitted even though it does not provide the level of safety now required by §192.145.
Sincerely,
Melvin A. Judah
Acting Associate Director
Pipeline safety regulation
Materials Transportation Bureau

<<<PAGE 2>>>

Kerotest Manufacturing Corp
2525 Liberty Avenue
Pittsburgh, PA 15222
April 16, 1981
Director, Office of Pipeline Safety Operations
Department of Transportation
2100 Second Street, S.W.
Washington D.C., 20590
Dear Sir:
Paragraph 192.145 of CFR stipulates that valves must meet the minimum requirements or the equivalent, of API
6A, API 6D, MSS SP-70, etc. Kerotest Mfg. Corp. at the present time has a unique situation regarding this paragraph.
We have been manufacturing a line of valves, the Model 1 Valve, which was developed around 1960, exclusively for the
natural gas industry. It had to be competitive with cast iron valves and yet have the capabilities of being welded in the
line. This was accomplished by making the bodies of steel and the covers of malleable iron. This acceptable combination
caused problems when it became necessary to adhere to a specific code.
We make a 275 WOG Series and a 500 WOG Series of valves. The 500 WOG is a cast iron rating (250 Series) and
conforms to MSS SP-70 since this specification states you can construct the valve from more qualified material than cast
iron. The 275 WOG is a steel rating (150 Series) and when the Federal Code incorporated API 6D, we had to put steel
covers on this class of valves for conformance. Prior to this, we sold thousands of these valves with the malleable covers.
Our interpretation of the Federal Code is that we are permitted to place a valve rated at 500 WOG with a malleable
cover in a pipeline, but the 275 WOG valves, which is lower rated, must have a steel cover. This is not logical and we are
looking for a way to justify using malleable covers.
We are requesting your comments on this situation and request you advise us on what action we should take to
justify returning to malleable covers on the 275 WOG valves and still conform to the Federal Code. Should we formally
request a waiver?
It is requested you give this some thought and notify us of your recommendations. Thank you for your time and
effort.
Yours truly,
E. L. Schmitt
Kerotest Manufacturing Corporation

## Provenance

- Official: Yes
- Source: <https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1981/g81-08-18_Schmitt_192.145-nlmx.pdf>
- Source ID: `phmsa`
- SHA-256: `2aadbbfb1f82d8d5589317392ef94e8c194322cb35fcfa7253c0c07c806a87c8`
- Retrieved: 2026-08-20T00:59:31.977Z
- Exported: 2026-08-23T16:11:48.969Z
- Document slug: `phmsa-interpretation-pi-81-0112`

### Source metadata

```json
{
  "materialSubtype": "interpretation",
  "interpretationArea": "pipeline_safety",
  "representation": "full_text_from_official_pdf",
  "companies": [],
  "individuals": [],
  "refIds": [
    "PI-81-0112"
  ],
  "catalogDates": [
    "1981-08-18"
  ],
  "catalogParts": [
    192
  ],
  "catalogRowCount": 1,
  "sourceRecordUrls": [
    "https://www.phmsa.dot.gov/node/52621"
  ],
  "linkedAttachmentUrls": [],
  "unavailableResponseUrls": [],
  "duplicateRepresentationUrls": [],
  "citedSections": [
    "192.145"
  ],
  "catalogPageUrls": [
    "https://www.phmsa.dot.gov/regulations/title49/section/192145"
  ],
  "pdfUrls": [
    "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1981/g81-08-18_Schmitt_192.145-nlmx.pdf"
  ],
  "representations": [
    {
      "viewUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1981/g81-08-18_Schmitt_192.145-nlmx.pdf",
      "detailUrl": null,
      "detailHtmlPath": null,
      "pdfUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1981/g81-08-18_Schmitt_192.145-nlmx.pdf",
      "pdfArtifactPath": "data/sources/phmsa-interpretations/pi-81-0112.pdf",
      "pdfArtifactSha256": "98c2cc61460f5802a7d1bf81fd969e58a54223c568b47fd1f577e3283d93f0da",
      "extractedTextPath": "data/sources/phmsa-interpretations/pi-81-0112.v2.txt",
      "extractedTextSha256": "66d71967ee111d4eff3f4e9c421da14fb8f1d1001b444ee16acf61a7127625ad",
      "pageCount": 2,
      "extractionVersion": 2
    }
  ],
  "caveat": "Interpretations apply regulations to the facts presented and do not create independently enforceable requirements.",
  "jurisdiction": "US"
}
```