<<<PAGE 1>>>

July 16, 1992
Mr. Brian E. Pierzina
Senior Engineer
Office of Pipeline Safety
Minnesota Department of Public Safety
175 Aurora Avenue
St. Paul, MN 55103-2356
Dear Mr. Pierzina:
I am responding to your letter of June 29, 1992, to George W. Tenley, Jr., about the uprating
requirements of Subpart K of 49 CFR Part 192.
Specifically, you asked whether § 192.557(b)(6) applies only when a low pressure distribution
system is uprated to a high pressure distribution system. Because § 192.557(b)(6) requires the
installation of service regulators, the purpose of this regulation is to require proper pressure
controls when a low pressure distribution system is uprated to a high pressure distribution system.
As these regulators would already be in place on high pressure distribution systems, §
192557(b)(6) does not apply to the uprating of a high pressure distribution system.
Sincerely,
/signed/
Cesar De Leon
Director, Regulatory Programs
Office of Pipeline Safety
DB
C:\WP51\INTERPRT\192\557\92-07-16
1

## Provenance

- Official: Yes
- Source: <https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1992/PI92032.pdf>
- Source ID: `phmsa`
- SHA-256: `0643c5fc09a66ab2759081d150c2a5509d3e46c2b4c2a88d7e1afeb11ffa6968`
- Retrieved: 2026-08-20T00:59:31.977Z
- Exported: 2026-08-22T14:24:44.678Z
- Document slug: `phmsa-interpretation-pi-92-032`

### Source metadata

```json
{
  "materialSubtype": "interpretation",
  "interpretationArea": "pipeline_safety",
  "representation": "full_text_from_official_pdf",
  "companies": [
    "Minnesota Department of Public Safety"
  ],
  "individuals": [
    "Brian E. Pierzina"
  ],
  "refIds": [
    "PI-92-032"
  ],
  "catalogDates": [
    "1992-07-16"
  ],
  "catalogParts": [
    192
  ],
  "catalogRowCount": 1,
  "sourceRecordUrls": [
    "https://www.phmsa.dot.gov/node/57756"
  ],
  "linkedAttachmentUrls": [],
  "unavailableResponseUrls": [],
  "duplicateRepresentationUrls": [],
  "citedSections": [
    "192.557",
    "192.557(b)(6)"
  ],
  "catalogPageUrls": [
    "https://www.phmsa.dot.gov/regulations/title49/section/192557"
  ],
  "pdfUrls": [
    "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1992/PI92032.pdf"
  ],
  "representations": [
    {
      "viewUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1992/PI92032.pdf",
      "detailUrl": null,
      "detailHtmlPath": null,
      "pdfUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1992/PI92032.pdf",
      "pdfArtifactPath": "data/sources/phmsa-interpretations/pi-92-032.pdf",
      "pdfArtifactSha256": "0e8d555b8c13f4c335f3efaf839ec9c3d11dd8789d035752844cda07db9e300e",
      "extractedTextPath": "data/sources/phmsa-interpretations/pi-92-032.v2.txt",
      "extractedTextSha256": "cb12f1de1d446addded47f8acaeb9ed2f7119c326925b15cc9f71c9c8f492281",
      "pageCount": 1,
      "extractionVersion": 2
    }
  ],
  "caveat": "Interpretations apply regulations to the facts presented and do not create independently enforceable requirements.",
  "jurisdiction": "US"
}
```