# Americas Marketing Group, Inc. — Pipeline Safety Interpretation

**Citation:** PI-96-0100  
**Type / status:** guidance / guidance  
**Agency:** Pipeline and Hazardous Materials Safety Administration  
**Effective:** Not stated  
**Published:** 1996-03-04

PI-96-0100 response to Americas Marketing Group, Inc. concerning 192.145.

## Document text

<<<PAGE 1>>>

PI-96-0100
March 4, 1996
Mr. Mike T. Deason
President
Americas Marketing Group, Inc.
P. 0. Box 100849
Birmingham, Alabama 35210
Dear Mr. Deason:
This is in response to your recent letters, in which you requested an interpretation of 49 CFR §192.145, in regards to
testing valves. As you noted in your letter, Section 192.145 requires that valves meet the minimum requirements, or
equivalent, of API 6D.
According to your letter, in your conversation with the American Petroleum Institute you were told that there was no
accepted equivalent to the hydrostatic test listed in API-6D. You also indicated that you were unable to get written
statements from the American National Standards Institute (ANSI) and the Manufacturers Standardization Society (MSS)
that the testing requirements for valves in their standards were equivalent to API 6D standard. This lead you to conclude
that there were no equivalent testing requirements to API 6D. Therefore, you requested interpretation of "or
equivalent" in Section 192.145, and request that we advise you of an equivalent to the hydrostatic test.
Published standards do not cover all types and sizes of valves that are manufactured. However, there are certain basic
safety features that can be applied to all valves. In Section 192.145, the word "or equivalent" is used in the sense of
accepting another standard that provides an equivalent level of safety to API 6D, including quality control and inspection
to API 6D. The term "or equivalent" is not necessarily used with regard to hydrostatic or air test or any other specific
features of industry standards. Other nationally recognized testing and valve standards such as API 598, Valve Inspection
and Testing, API 608, Metal Ball Valves - Flanged and Butt-weld Ends, and MSS-SP-61, Pressure Testing of Steel Valves,
allow the use of air as the test medium. In addition, we have enclosed a copy of Technical Report NE-169, "Weldball
Valve Leakage Analysis, Air versus Water" supplied by Kerotest Manufacturing Corporation, that may help you in
identifying equivalent standards, such as ISO 5208 that is referenced in the report.
By not restricting minimum requirements to meet only API 6D standard, we are, in fact encouraging new developments
in manufacturing and testing of valves, due to the changes in technology.
We trust that this interpretation will answer any question you might have.
Sincerely,
Richard B. Felder
Associate Administrator
for Pipeline Safety

<<<PAGE 2>>>

State of Florida
Public Service Commission
Capital Circle Office Center
2540 Shumard Oak BLVD
Tallahassee, FL 32399-0850
February 28, 1996
Mike T. Deason, President
Americas Marketing Group, Inc.
& M. T. Deason Company, Inc.
P.O. Box 100849
Birmingham, Alabama 35210
Re: Information Request Regarding Code of Federal Regulations, 192.145 Valves
Dear Mr. Deason:
The Commission has a rule, 25-12.028, Florida Administrative Code, requiring the marking of materials used in
natural gas pipelines. This rule states that each valve must be clearly marked as prescribed in the specification or
standard, to which it was manufactured.
The Code of Federal Regulations (CFR), Part 192.145 Valves, requires valves to meet the minimum requirements
of the American Petroleum Institute (API), Specification 6D, "Specification for pipeline Valves (Gate, Plug, Ball, and Check
Valves)" (20th edition, 1991). Hydrostatic pressure testing of valves is the minimum required by API 6D. The American
Petroleum Institute has recently reaffirmed its minimum hydrostatic testing requirements for valves to the natural gas
industry.
Florida law requires valves to be marked, using the specification of the standard by which they are
manufactured, and API 6D is the only approved standard at this time. This may change if the United States Department
of Transportation or the American Petroleum Institute are forthcoming with additional information.
If you have any further questions, contact me at (904) 413-6650.
Respectfully,
C. Edward Mills, Supervisor
Engineering and Safety
Bureau of Gas Regulation

<<<PAGE 3>>>

Americas Marketing Group, Inc.
P.O Box 100849
Birmingham, Alabama 35210
February 26, 1996
Mr. Cesar De Leon
U.S. Department of Transportation
RSPA/Office of Pipeline Safety
400 7th Street SW
Washington, DC 20590
Reference: 192.145 Valves, API-6D or "equivalent". Dear Mr, De Leon:
I hope at the writing of this letter that you have received the copy of ISO 5208 ( International Standard for
Testing Industrial Valves) that I mailed you on February 15, 1996. Please find a letter enclosed that I received from Mr.
J.D. Greer, Senior E&P Associate with the American Petroleum Institute. Mr. Greer confirms in this letter that API-6D
specification requires hydrostatic shell testing for steel valves and has no provisions for air testing in lieu of the
hydrostatic test.
In my telephone conversation with you on February 15, 1996, you discussed with me the ISO test. I committed
during our conversation to provide you with the ISO 5208 test you made reference to. The ISO 5208 standard has
provisions for testing with a fluid listed under section 2.2 and 2.2.1 on page one. I also refer you to 4.1.1 and 4.1.2 of the
standard that requires testing with a fluid having the velocity not greater than that of water.
Broen, manufacturer of the BALLOMAX steel ball valves, interprets 192.145 of the Code of Federal Regulations,
that each valve must meet the minimum requirements, or "equivalent" of API-6D standard for testing valves. Therefore,
the American Petroleum Institute has clearly defined there is no equivalent for air testing. Also, the ISO 5208 test has
provisions for hydrostatically testing valves.
The interpretation we, Americas Marketing Group Inc., representing Broen, are requesting relates to air testing
of valves under 192.145 of the Code of Federal Regulations. In my opinion, the interpretation of this section of the code
must come from Mr. Richard B. Felder, Associate Administrator, U.S. Department of Transportation, Office of Pipeline
Safety, 400 Seventh St. S.W. Room 2335, Washington, D.C., 20590.
To date no one with this agency has had the courtesy to respond to any of our request for an interpretation in
writing. Our company is experiencing a price disadvantage in regards to manufacturers testing with air. Your delay and
non-response has cost our company sales. Our company meets the requirements and test procedures under API-6D. In
the event of an accident, what ruling or interpretation would DOT render in regards to "air testing" steel valves under
this section of the code? In the interest of safety, how could any valve company be requested on a 900 ANSI valve, to
perform a minimum air shell test to 3250 PSI? I hope you would agree the valve company would have a potential bomb.
Our company has gone through the appropriate and suggested chain of command in regards to our request for
this interpretation of the code. If I receive no written response you leave me no alternative but to solicit help from my
state senator.
I look forward to your written response and interpretation of what is "equivalent" to API-6D. If the air test is
equivalent, please state so.
With warmest personal regards, I remain,
Yours truly,
Americas Marketing Group, Inc.
Mike T. Deason
President

<<<PAGE 4>>>

American Petroleum Institute
Exploration & Production Department
1220 L Street, NW
Washington, DC 20005
Phone: (202) 682-8000
Fax: (202) 682-8426
J. D. Greer
Senior E&P Associate
Direct Line: (202) 682-8494
February 16, 1996
Mr. Mike Deason, President
Americas Marketing Group Inc.
PO Box 100849
Birmingham, AL 35210
Re: API Spec 6D, Specification for Pipeline Valves (Gate, Plug, Ball and Check Valves), 21st Edition, March 31, 1994
Dear Mr. Deason:
Per our telephone conversation today, this confirms that API Spec 6D requires hydrostatic shell testing, and has no
provision for air testing in lieu of hydrostatic testing. This is clearly shown in Par. 5.1 and 5.2 of Section 5, "Tests" as
shown below with underlining added for emphasis:
5.1 Pressure Tests. Each valve shall be tested as set out in this section prior to shipment from the
manufacturer's works. These tests shall be performed in accordance with the manufacturer's written
procedures. The manufacturer shall complete shell pressure tests before painting the valves. Tests shall be made
in the sequence shown in the following paragraphs. Additional tests such as those in Appendix C may be
performed by the manufacturer, after the tests in Sections 5.2 and 5.3 unless otherwise noted in Appendix C.
5.2 Shell Test. Valves shall be subjected to a hydrostatic shell test. . . .
Appendix C allows hydrostatic testing at higher pressures or for longer times than specified in Section 5.2 (Par. C2), but
has no provision for air shell testing.
Sincerely,

<<<PAGE 5>>>

Americas Marketing Group, Inc.
P.O. Box 100849
Birmingham, Alabama 35210
February 15, 1996
Mr. Cesar De Leon
U.S. Department of Transportation
RSPA/Office of Pipeline Safety
400 7th Street SW
Washington, DC 20590
Reference: ISO 5208
Dear Mr. De Leon:
Enclosed is a copy of the International Standard ISO 5208 for your review. Please read this and let me know if
this is considered an "equivalent" referred to in 192.145. Thank you for the time and courtesy you have extended me
over the phone today. I am contacting Mr. Jim Greer today with API and will keep you informed of my progress. I hope
you would agree whoever wrote the word "equivalent" in the code certainly gave DOT the responsibility to interpret
what is "equivalent" or the code is left to the interpretation of anyone who manufacturers valves. I have always believed
the Code of Federal Regulations set standards for the natural gas industry to follow. Even though I respect your position,
I totally disagree and fully believe that the interpretation of this statement must come from the Department of
Transportation.
It is our opinion that all interpretations regarding code compliance and an official interpretation of the
requirements of standards must come from the U.S. Department of Transportation: Office Pipeline Safety, Washington,
DC, 20590.
I respectfully request your reply in writing and hope you would present this to your legal staff as mentioned over
the phone.
Sincerely,
AMERICAS MARKETING GROUP, INC.
Mike T. Deason
President

<<<PAGE 6>>>

Americas Marketing Group, Inc.
P.O. Box 100849
Birmingham, Alabama 35210
January 3, 1996
Mr. Cesar De Leon
U.S. Department of Transportation
RSPA/Office of Pipeline Safety
400 7th Street SW
Washington, DC 20590
Subject: Code of Federal Regulations, Title 49, Part 192, Section 192.145, Minimum Requirements for Testing
Natural Gas Valves
Dear Mr. De Leon:
I want to thank you for the courtesy you extended me yesterday over the telephone. Please find enclosed some
of the correspondence with state and federal officials regarding testing of steel valves per the above code.
We, Americas Marketing Group, Inc., are the master distributor for Broen Industries for their steel BALLOMAX
ball valve. All valves are hydrostatically tested per API 6-D which is referenced in 192.145 of the Federal Code.
Please render an interpretation of this section of the code regarding testing. Does an air test meet the
requirements of this section of the code?
Our company is hydrostatically testing all valves. Some of our competitors are interpreting the code that an air
test meets 192.145. Our company is at a tremendous disadvantage from a competitive situation by performing the
hydrostatic test if it is not required under 192.145.
We respectfully request in writing an interpretation of this code so our company can compete in the natural gas
distribution market with our competitors.
With warmest personal regards, I remain,
Yours truly,
Mike T. Deason

<<<PAGE 7>>>

Americas Marketing Group, Inc.
P.O. Box 100849
Birmingham, Alabama 35210
December 21, 1995
Mr. Richard B. Felder
Associate Administrator for Pipeline Safety, DPS-1
400 7th Street, SW
Washington, DC 20590
Subject: Code of Federal Regulations, Title 49, Part 192, Section 192.145, Minimum Requirements for Testing
Natural Gas Valves
Dear Mr. Felder,
I want to thank you for the time and courtesy you extended me this morning over the telephone.
We have experienced much confusion in regards to testing of steel valves referred to in the above section of the
code of Federal Regulations. The confusion surrounds the word "equivalent". I am enclosing for your review the
correspondence between Americas Marketing Group, Inc. and federal and local authorities.
We, Americas Marketing Group, Inc., have been referred to you for an interpretation of the code. I know you
would agree that no manufacturer of a product is in a position to interpret the code for a gas system. It is our obligation
to make sure we meet or exceed the minimum requirements.
Certain manufacturers of steel valves have taken upon themselves the responsibility to inform customers that
an air test is equivalent to the API 6-D hydro test. If the air test meets the Code of Federal Regulations, would you please
notify us in writing so we will no longer be required to hydrostatically test each valve per API 6-D. A manufacturer
required to perform the API 6-D test and mark valves accordingly is at a tremendous price disadvantage against
competition only performing the air test.
It is our position that steel valves must be hydrostatically tested as specified in the standard unless you rule and
give the specific interpretation of the word "equivalent". It is our opinion that the interpretation of this requirement
must come from your office only.
Please accept this letter and enclosed correspondence as our genuine effort not to misinform our natural gas
clients. Our sincere interest is to assist in the development of pipeline safety.
Yours truly,
John M. Webb
Sales Representative
Americas Marketing Group, Inc

## Provenance

- Official: Yes
- Source: <https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1996/g96_03_04_Deason_192.145_nlmx.pdf>
- Source ID: `phmsa`
- SHA-256: `9844dfb82ba74acc446aaec2819d4afd1f2e0e695dac1c96037af2712867a6fe`
- Retrieved: 2026-08-20T00:59:31.977Z
- Exported: 2026-08-23T01:08:10.739Z
- Document slug: `phmsa-interpretation-pi-96-0100`

### Source metadata

```json
{
  "materialSubtype": "interpretation",
  "interpretationArea": "pipeline_safety",
  "representation": "full_text_from_official_pdf",
  "companies": [
    "Americas Marketing Group, Inc."
  ],
  "individuals": [
    "Mr. Mike T. Deason"
  ],
  "refIds": [
    "PI-96-0100"
  ],
  "catalogDates": [
    "1996-03-04"
  ],
  "catalogParts": [
    192
  ],
  "catalogRowCount": 1,
  "sourceRecordUrls": [
    "https://www.phmsa.dot.gov/node/51221"
  ],
  "linkedAttachmentUrls": [],
  "unavailableResponseUrls": [],
  "duplicateRepresentationUrls": [],
  "citedSections": [
    "192.145"
  ],
  "catalogPageUrls": [
    "https://www.phmsa.dot.gov/regulations/title49/section/192145"
  ],
  "pdfUrls": [
    "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1996/g96_03_04_Deason_192.145_nlmx.pdf"
  ],
  "representations": [
    {
      "viewUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1996/g96_03_04_Deason_192.145_nlmx.pdf",
      "detailUrl": null,
      "detailHtmlPath": null,
      "pdfUrl": "https://www.phmsa.dot.gov/sites/phmsa.dot.gov/files/legacy/interpretations/Interpretation%20Files/Pipeline/1996/g96_03_04_Deason_192.145_nlmx.pdf",
      "pdfArtifactPath": "data/sources/phmsa-interpretations/pi-96-0100.pdf",
      "pdfArtifactSha256": "efc2acc9afadee95d3e44e06ae611b47182b179c02127b76c9bced6bb05b61c4",
      "extractedTextPath": "data/sources/phmsa-interpretations/pi-96-0100.v2.txt",
      "extractedTextSha256": "3bc50b6623a42ed279055917a0249b6b34014ae5f6bd147a99e9a1082c5fc19f",
      "pageCount": 7,
      "extractionVersion": 2
    }
  ],
  "caveat": "Interpretations apply regulations to the facts presented and do not create independently enforceable requirements.",
  "jurisdiction": "US"
}
```
