{"operation":"document","citation":"49 CFR 192.369","title":"Service lines: Connections to cast iron or ductile iron mains.","source_type":"regulation","agency":"Pipeline and Hazardous Materials Safety Administration","status":"current","official":true,"published_on":null,"effective_on":"2026-08-18","summary":"(a) Each service line connected to a cast iron or ductile iron main must be connected by a mechanical clamp, by drilling and tapping the main, or by another method meeting the requirements of § 192.273.\n\n(b) If a threaded tap is being inserted, the requirements of § 192.151 (b) and (c) must also be ","machine_formats":{"json":"https://regulus.evalyn.ai/document/49-cfr-192-369.json","markdown":"https://regulus.evalyn.ai/document/49-cfr-192-369.md"},"app_url":"https://regulus.evalyn.ai/document/49-cfr-192-369","source_url":"https://www.ecfr.gov/on/2026-08-18/title-49/section-192.369","body":"(a) Each service line connected to a cast iron or ductile iron main must be connected by a mechanical clamp, by drilling and tapping the main, or by another method meeting the requirements of § 192.273.\n\n(b) If a threaded tap is being inserted, the requirements of § 192.151 (b) and (c) must also be met.","truncated":false,"body_characters":304}