{"operation":"document","citation":"192.233","title":"Miter Joints","source_type":"regulation","agency":"Arkansas Public Service Commission","status":"current","official":true,"published_on":null,"effective_on":null,"summary":"§ 192.233 Miter Joints (a) A miter joint on steel pipe to be operated at a pressure that produces a hoop stress of 30 percent or more of SMYS may not deflect the pipe more than 3°. (b) A miter joint on steel pipe to be operated at a pressure that produces a hoop stress of less than 30 percent, but m","machine_formats":{"json":"https://regulus.evalyn.ai/document/ar-car-23-500-192-233.json","markdown":"https://regulus.evalyn.ai/document/ar-car-23-500-192-233.md"},"app_url":"https://regulus.evalyn.ai/document/ar-car-23-500-192-233","source_url":"https://codeofarrules.arkansas.gov/Rules/Rule?chapterID=40&levelType=part&partID=1394&subChapterID=392&titleID=23","body":"§ 192.233 Miter Joints (a) A miter joint on steel pipe to be operated at a pressure that produces a hoop stress of 30 percent or more of SMYS may not deflect the pipe more than 3°. (b) A miter joint on steel pipe to be operated at a pressure that produces a hoop stress of less than 30 percent, but more than 10 percent, of SMYS may not deflect the pipe more than 12 1/2° and must be a distance equal to one pipe diameter or more away from any other miter joint, as measured from the crotch of each joint. (c) A miter joint on steel pipe to be operated at a pressure that produces a hoop stress of 10 percent or less of SMYS may not deflect the pipe more than 90°.","truncated":false,"body_characters":664}