- **summary:** § 192.355 Customer Meters and Regulators: Protection from Damage (a) Protection from vacuum or back pressure. If the customer's equipment might create either a vacuum or a back pressure, a device must be installed to protect the system. (b) Service regulator vents and relief vents. Service regulator
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/ar-car-23-500-192-355.json
- **markdown:** https://regulus.evalyn.ai/document/ar-car-23-500-192-355.md
- **app url:** https://regulus.evalyn.ai/document/ar-car-23-500-192-355
- **source url:** https://codeofarrules.arkansas.gov/Rules/Rule?chapterID=40&levelType=part&partID=1394&subChapterID=392&titleID=23
**body:**

§ 192.355 Customer Meters and Regulators: Protection from Damage (a) Protection from vacuum or back pressure. If the customer's equipment might create either a vacuum or a back pressure, a device must be installed to protect the system. (b) Service regulator vents and relief vents. Service regulator vents and relief vents must terminate outdoors, and the outdoor terminal must- (1) Be rain and insect resistant; (2) Be located at a place where gas from the vent can escape freely into the atmosphere and away from any opening into the building; and (3) Be protected from damage caused by submergence in areas where flooding may occur. (c) Pits and vaults. Each pit or vault that houses a customer meter or regulator at a place where vehicular traffic is anticipated, must be able to support that traffic.