# Remedial Measures: Cast Iron and Ductile Iron Pipelines

- **operation:** document
- **citation:** 192.489
- **title:** Remedial Measures: Cast Iron and Ductile Iron Pipelines
- **source type:** regulation
- **agency:** Arkansas Public Service Commission
- **status:** current
- **official:** true
- **published on:** Not available
- **effective on:** Not available
- **summary:** § 192.489 Remedial Measures: Cast Iron and Ductile Iron Pipelines (a) General graphitization. Each segment of cast iron or ductile iron pipe on which general graphitization is found to a degree where a fracture or any leakage might result, must be replaced. (b) Localized graphitization. Each segment
- **machine formats:** - **json:** https://regulus.evalyn.ai/document/ar-car-23-500-192-489.json
- **markdown:** https://regulus.evalyn.ai/document/ar-car-23-500-192-489.md
- **app url:** https://regulus.evalyn.ai/document/ar-car-23-500-192-489
- **source url:** https://codeofarrules.arkansas.gov/Rules/Rule?chapterID=40&levelType=part&partID=1394&subChapterID=392&titleID=23
**body:**

§ 192.489 Remedial Measures: Cast Iron and Ductile Iron Pipelines (a) General graphitization. Each segment of cast iron or ductile iron pipe on which general graphitization is found to a degree where a fracture or any leakage might result, must be replaced. (b) Localized graphitization. Each segment of cast iron or ductile iron pipe on which localized graphitization is found to a degree where any leakage might result, must be replaced or repaired, or sealed by internal sealing methods adequate to prevent or arrest any leakage.
- **truncated:** false
- **body characters:** 532