{"operation":"document","citation":"RCSA § 16-280b-A15","title":"Establishing or reestablishing service","source_type":"regulation","agency":"Connecticut Public Utilities Regulatory Authority","status":"current","official":true,"published_on":"2025-06-11","effective_on":"2025-06-11","summary":"(a) No Operator shall establish service where any of the following conditions are present: (1) the Service Line is undersized for the anticipated load and the load cannot be reduced to acceptable levels by isolation of select Gas utilization equipment; (2) the above-ground portion of the Service Line is not compliant w","machine_formats":{"json":"https://regulus.evalyn.ai/document/ct-rcsa-16-280b-a15.json","markdown":"https://regulus.evalyn.ai/document/ct-rcsa-16-280b-a15.md"},"app_url":"https://regulus.evalyn.ai/document/ct-rcsa-16-280b-a15","source_url":"https://eregulations.ct.gov/eRegsPortal/Search/getDocument?guid=%7BE04F6097-0000-CC1C-9D68-25A0BA411C82%7D","body":"(a) No Operator shall establish service where any of the following conditions are present: (1) the Service Line is undersized for the anticipated load and the load cannot be reduced to acceptable levels by isolation of select Gas utilization equipment; (2) the above-ground portion of the Service Line is not compliant with the Operator's Procedures; (3) customer piping has not passed a pressure test as required by the Authority Having Jurisdiction; (4) Gas flow is detected through customer piping despite all Gas utilization equipment being shut off; or (5) the Authority Having Jurisdiction has found the customer piping to be non- compliant. 9 (b) No Operator shall reestablish service where subsections (a)(1), (a)(4), or (a)(5) of this section are present. In addition, no Operator shall reestablish service where the non- compliance in subsection (a)(2) of this section is an immediate safety concern. This subsection does not apply to interruptible customers who were shut off due to supply constraints.","truncated":false,"body_characters":1013}