{"operation":"document","citation":"RCSA § 16-280b-A66","title":"Leak repair","source_type":"regulation","agency":"Connecticut Public Utilities Regulatory Authority","status":"current","official":true,"published_on":"2025-06-11","effective_on":"2025-06-11","summary":"(a) Mechanical leak repair clamps shall not be used as a permanent repair method for plastic Pipe. (b) Mechanical leak repair clamps may be used as a temporary repair method for plastic Pipe if: (1) the manufacturer of the clamp certifies its use as a temporary repair; (2) the clamp is not backfilled; (3) the clamp is ","machine_formats":{"json":"https://regulus.evalyn.ai/document/ct-rcsa-16-280b-a66.json","markdown":"https://regulus.evalyn.ai/document/ct-rcsa-16-280b-a66.md"},"app_url":"https://regulus.evalyn.ai/document/ct-rcsa-16-280b-a66","source_url":"https://eregulations.ct.gov/eRegsPortal/Search/getDocument?guid=%7BE04F6097-0000-CC1C-9D68-25A0BA411C82%7D","body":"(a) Mechanical leak repair clamps shall not be used as a permanent repair method for plastic Pipe. (b) Mechanical leak repair clamps may be used as a temporary repair method for plastic Pipe if: (1) the manufacturer of the clamp certifies its use as a temporary repair; (2) the clamp is not backfilled; (3) the clamp is not in use for more than 120 calendar days; and (4) the clamp is checked for Gas leakage at least once each calendar week, but at intervals not exceeding 9 calendar days.","truncated":false,"body_characters":490}